Part NumberDescriptionAssociated Systems
375-0001Token Ring Interface (TRI/P) Token Ring Interface (TRI/P) 9-Pin Data Cable (not included and not sold)Communication
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 280R
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
375-0002GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15MEthernet
Sun Enterprise 10000
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 10
Sun Ultra 30
375-0003GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15MEthernet
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
375-0005Dual Single-Ended Ultra SCSI without FCode Dual Single-Ended Ultra SCSI with FCode ( not released ) E450 Internal A-Port and B-Port Cable External HD68 to VHDCI68 Cable, 80 cm External HD68 to VHDCI68 Cable, 2MSCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun StorEdge L9
Sun StorEdge S1
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
375-0006SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected.SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
375-0007Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68SCSI
Sun StorEdge A1000
375-0008Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68SCSI
Sun StorEdge Array Controller D1000
375-0009300/333MHz (Ultra 10)
375-0009-05Ultra 5 and Ultra10 systems may experience fuzzy video, slow booting, and serial port hang when using the external clock source as transfer clock in SYNC mode (X.25).Sun Ultra 10
Sun Ultra 5
375-001232MB SBus NVRAM BoardSun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun Ultra 2
375-0013Dual Single-Ended Ultra SCSI without FCode Dual Single-Ended Ultra SCSI with FCode ( not released ) E450 Internal A-Port and B-Port Cable External HD68 to VHDCI68 Cable, 80 cm External HD68 to VHDCI68 Cable, 2MSCSI
375-0014Dual Differential Ultra SCSI without FCode Dual Differential Ultra SCSI with FCode ( not released ) E450 Internal A-Port and B-Port Cable External HD68 to VHDCI68 Cable, 80 cm External HD68 to VHDCI68 Cable, 2MSCSI
375-0015Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68SCSI
Sun StorEdge A1000
Sun StorEdge N8200
375-0015-03When a failed controller board is replaced in the A1000 StorEdge Array, it is necessary to first verify the RAID Manager software version being used, the controller firmware level, and the controller memory size. Failure to do so may result in the wrong FRU being installed. This will result in incompatibility between the controller firmware and the RAID Manager software. This can cause LUN's under the A1000 to be inaccessible and cause data access problems.Sun StorEdge A1000
375-0016Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68SCSI
Sun StorEdge A1000
375-0016-03When a failed controller board is replaced in the A1000 StorEdge Array, it is necessary to first verify the RAID Manager software version being used, the controller firmware level, and the controller memory size. Failure to do so may result in the wrong FRU being installed. This will result in incompatibility between the controller firmware and the RAID Manager software. This can cause LUN's under the A1000 to be inaccessible and cause data access problems.Sun StorEdge A1000
375-0040Any FC-AL PCI loop where A5X00 Storage Arrays are directly connected to i) a host using PCI FC100/P initiator card without hub, or ii) other host (dual host) with FC-AL initiator-card is connected to the same loop may experience the following errors as described in BugId 4243157. Sample error messages: Dec 8 05:18:17 name unix: transport rejected (-2) Dec 8 05:18:17 name unix: Dec 8 05:18:17 name unix: WARNING: /pci@4,4000/SUNW, ifp@4/ssd@w2100002037141659,0 (ssd32) Dec 8 05:18:17 name unix: transport rejected (-2) Dec 8 05:18:17 name unix: Dec 8 05:18:18 name unix: ifp0: LIP occurred Dec 8 05:18:18 name unix: ifp0: Loop up Dec 8 05:18:18 name unix: ifp0: Loop reconfigure in progress Dec 8 05:18:18 name unix: ifp0: Loop reconfigure done Dec 8 08:17:41 name unix: ifp0: Loop down Dec 8 08:17:46 name unix: ifp0: LIP reset occurred UPDATE FOR FIN I0541-2: The Corrective Action on FIN I0541-1 provides two different options or solutions to the above mentioned problems as follows: OPTION-1: The FC100/P card is the only Initiator on any one loop where Sun A5x00 Storage Array are direct connected. OPTION-2: A Sun FCAL hub is placed between the FC100/P card(s), and the A5X00 Storage Array. In this case, more than one host-adapter on the same loop, may be used. Due to resistance from the Field over the cost of implementation, OPTION-2 has been removed from the Corrective Action. This option would have required the customer to purchase and connect a hub to the A5x00 Storage Array. The Corrective Action now recommends only OPTION-1 for avoiding this FC100/P card problem. This restriction is advantageous from high-availability/RAS point of view since having each host on a separate loop removes a single point Of failure (SPOF) in Multi Initiator configurations.Fibre Channel
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire V120
Sun Netra t1
Sun StorEdge A3500
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun Ultra 60
Sun Ultra 80
T3
375-0040-01FC100/P FC-AL PCI Card (375-0040-02 or below)Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun Ultra 60
Sun Ultra 80
375-0040-02A host system using the 375-0040-01 or -02 FC-AL PCI card to attach to FC-AL storage, may experience loop errors which affect data access to that storage. In extreme cases, this can result in the host losing its connection to the storage completely. However, it is more common for the loop errors to be intermittent initially, perhaps becoming more frequent over a period of days or a few weeks. The failures are sometimes sensitive to the data pattern on the FC-AL loop, so they are not always reproducible with current diagnostic software. Below are examples of error messages; unix: ifp0: Loop down unix: ifp0: Loop is down: finishing off loop reconfig unix: ifp0: Loop reconfigure done, LIP unix: WARNING: /pci@1f,2000/SUNW,ifp@1/ssd@w21000020370d323b,0 (ssd58): unix: requeue of command fails (fffffffe) - or - unix: WARNING: /pci@1f,2000/SUNW,ifp@1/ssd@w21000020371430cd,0(ssd2): unix: Error for Command: write(10) Error Level: Retryable unix: Requested Block: 4241 Error Block: 4241 unix: Vendor: SEAGATE Serial Number: 9833X17325 unix: Sense Key: Aborted Command unix: ASC: 0x47 (scsi parity error), ASCQ: 0x0, FRU: 0x3Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun StorEdge A3500
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun Ultra 60
Sun Ultra 80
375-0064375-0088
375-0066Shipped Speeds: * U5: 270/333MHz U10: 333/360MHz
375-0066-03Reverse capacitor failure in Ultra 5 and Ultra 10 systems. Reverse bias voltage in excess of 20% of manufacturing specification will cause early life failure of the capacitor and, in addition, may cause damage to surrounding PCB or components and/or product functional failure.Sun Ultra 10
Sun Ultra 5
375-0071Sun Fire V880 DC Power Distribution BoardPower Supplies
Sun Fire V880
375-0073Token Ring Interface (TRI/P) Token Ring Interface (TRI/P) 9-Pin Data Cable (not included and not sold)Communication
Sun Blade 100
Sun Blade 1000
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 280R
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
375-0075SunPCi 300MHz
375-0078SCSI RAID Controller SRC/P DPT PM3755U2B SmartRAID Millennium DPT DM4050-64 64MB DIMM DPT BB4050 Battery Backup Module DPT BP-0001-001 2.4V Battery DPT SX4055U2-2 SCSI Expansion Module External HD68 to VHDCI68 Cable, 2M (obsolete) External HD68 to VHDCI68 Cable, 2M * (-02 required) E450 Internal 8-Disk Backplane CableSCSI
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 280R
Sun Netra 20
375-0078-01Numerous error conditions may result from using the StorEdge SRC/P RAID controller with Firmware Version SM02.Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
375-0078-02Numerous error conditions may result from using the StorEdge SRC/P RAID controller with Firmware Version SM02.Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
375-0079New NVRAM (525-1817) is incompatible with the Ultra 5/10 system board (375-0079), so a new system board (375-0115) was created for the new NVRAM. And, approximately 1,200 system boards (375-0115) with the new NVRAM were incorrectly labeled with the 375-0079 part number.Sun Ultra 10
Sun Ultra 5
375-0081Sun Ray 1 Assembly/FRU without Stand (380-0299-05 or earlier) 100 MHz microSPARC IIep System Board Power Supply Note: 600-6166 includes stand 370-3918Sun Ray
375-0082SCSI RAID Controller SRC/P DPT PM3755U2B SmartRAID Millennium DPT DM4050-64 64MB DIMM DPT BB4050 Battery Backup Module DPT BP-0001-001 2.4V Battery DPT SX4055U2-2 SCSI Expansion Module External HD68 to VHDCI68 Cable, 2M (obsolete) External HD68 to VHDCI68 Cable, 2M * (-02 required) E450 Internal 8-Disk Backplane CableSCSI
375-0083T3 Chassis with Midplane Assembly Chassis MidplaneT3
375-0084There is a possibility that field personnel may have trouble inserting older-style (J9) StorEdge T3 controller FRU's into a newer-style T3 chassis. The J9 controller may require excessive force to insert and may fail to slide all the way into the chassis. This could result in the controller not seating properly and failing to function.T3
375-0084-01Sun StorEdge T3 (Purple) Arrays shipped prior to General Availability have the potential of experiencing intermittent parity or 'no cache found' errors. Sun StorEdge T3 Arrays with hubs are not supported with controllers earlier than revision J7. Shown below are typical error messages: 0 MBytes Cache Memory Detected 125722 Cache memory parity error detected To recover from the above failure the array would need to be rebooted. The problem results in a loss of data access, not actual data loss.T3
375-0085Interconnect BoardT3
375-008664MB PCI Fast Write CacheSun Enterprise 250
Sun Enterprise 450
Sun Ultra 60
Sun Ultra 80
375-0087Sun StorEdge Fast Write CacheSun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
375-0088375-0064
375-0093F6800 20MB Fire Link I/O Assembly, Option X4141A cPCI Filler Panel 20MB Fire Link I/O Assembly w Optical Module cPCI Fire Link Optical Module (Paroli) (×2) 20MB Fire Link I/O Assembly/FRU 10MB DIMM (×2) Fire Link I/O Assembly/FRUI/O
Sun Fire 12K / 15K
Sun Fire 6800
Switches
375-0094E220R DC-DC Converter Circuit DC-DC Converter Interposer BoardPower Supplies
Sun Enterprise 220R
Sun StorEdge N8200
375-0094-01VRM Interposer board (375-0094-01) can cause intermittent system resets in the Enterprise 220R under high-load conditions.Allgemein / Unbekannt
Sun Enterprise 220R
375-0095SunPCi I 400MHz
375-0096System Board UltraSPARCIIe (375-0096-07 or lower) System Board UltraSPARCIIe (375-3061-02 or lower)Sun Blade 100
375-0096-01SunBlade 100 systems may not auto-restart after a power failure.Sun Blade 100
375-0096-04Sun Blade 100 onboard graphics video displays may remain white and may not display console output.Sun Blade 100
375-0096-05Audio Noise from Sunblade 100 system speakers.Sun Blade 100
375-0096-07This FIN is to inform the field of a part number change on the Sun Blade 100 motherboard. Effective 6/13/2001, the motherboard P/N has been changed from 375-0096-xx to 375-3061-xx. The new motherboard (375-3061-xx) IS backward compatible however, the old motherboard (375-0096-xx) is NOT forward compatible. Both motherboards will be carried as FRU's.Sun Blade 100
375-0097Single-Channel Single-Ended Ultra/Wide SCSI (PCI)Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Ultra 10
Sun Ultra 5
375-0100Serial Asychronous Interface (SAI/P) 3.0 NEBS Level-3 8-Port I/O Panel and 78-Pin Cable Data Cable (not included and not sold)Communication
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
375-0103Sun Ray 1 Assembly/FRU without Stand (380-0299-06 or later) 100 MHz microSPARC IIep System Board Power Supply Note: 600-6166 includes stand 370-3918Sun Ray
375-0104Sun Ray 150 Assembly/FRU 100 MHz System Board Philo Board Note: 600-6808 consists of 380-0343, an ethernet cable (370-4232), an AC power adapter (370-4183), and manuals.Sun Ray
375-0105Sun Ray 100 Assembly/FRU 100 MHz microSPARC IIep System Board Note: 600-6809 consists of 380-0344, an Ethernet cable (370-4232), and manuals.Sun Ray
375-0106Right Drive Tray Board (replaces 370-3743)Sun StorEdge L11000
375-0107Right Drive Sideboard Board (replaces 370-3745)Sun StorEdge L11000
375-0108Left Drive Tray Board (replaces 370-3742)Sun StorEdge L11000
375-0109Left Drive Sideboard Board (replaces 370-3744)Sun StorEdge L11000
375-0113Sun Ray 150 Assembly/FRU 100 MHz System Board Philo Board Note: 600-6808 consists of 380-0343, an ethernet cable (370-4232), an AC power adapter (370-4183), and manuals.Sun Ray
375-0115New NVRAM (525-1817) is incompatible with the Ultra 5/10 system board (375-0079), so a new system board (375-0115) was created for the new NVRAM. And, approximately 1,200 system boards (375-0115) with the new NVRAM were incorrectly labeled with the 375-0079 part number.Sun Ultra 10
Sun Ultra 5
375-0116Expert3D Lite PCI Frame Buffer (6760B FAB)Sun Blade 100
T3
375-0116-01TestedT3
375-0116-02Not TestedT3
375-0116-03Not TestedT3
375-0118Compact PCI (cPCI) Dual Channel FCFibre Channel
Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
Sun StorEdge 3900/6900
Sun StorEdge 6920
Sun StorEdge 9990
Sun StorEdge A3500
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun StorEdge L5500
T3
375-0118-01Dual Channel Adapter w Firmware x.x Dual Channel Adapter w Firmware 1.13 (Patch 111853-01 ) Dual Channel Adapter w Firmware 1.14.09 (Patch 111853-02 ) Dual Channel Adapter w Firmware 1.14.09 (Patch 111853-03 ) Dual Channel Adapter w Firmware 1.14.10 (Patch 111853-04 )Firmware
375-0118-02Sun Fire x800 systems are subject to a "panic" problem at boot time when a cPCI Dual FC Network Adapter (FRU or X-option) is installed for the first time. If a customer installs this board and boots the system, they will see panic messages on the console and the boot will fail. However, any subsequent reboots will be successful. This may result in an unnecessary service call. This cPCI board (P/N 370-0118-02) has been shipped with Sun Fire X800 systems and as an X-option. The current estimate is that less than 1000 boards have been installed in systems and 1200 boards are in field stock (FRUs and x-options) as of 7/12/01.Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
375-0119Dual Differential Ultra SCSI, cPCI (Use for DLT8000)SCSI
Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
375-0120595-5949
375-0121375-3429
375-0128375-3014
375-0129Host Interface BoardSun Netra E1
375-0130Crypto Accelerator ICommunication
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 280R
Sun Fire V120
Sun Fire V1280
Sun Fire V480
Sun Fire V880
Sun Netra 20
Sun Netra t1
Sun Ultra 60
Sun Ultra 80
375-0131SunPCi II 600MHz, 64MB memory
375-0131-04SunPCi II and SunPCi IIpro cards may not respond after rapid/successive power cycling.Sun Blade 100
Sun Blade 1000
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 280R
Sun Ultra 10
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
375-01320MB (500MHz UltraSPARC IIe)
375-0132-02If Lights Out Management (LOM) firmware V3.8 or lower is installed, it may cause fan speed problem on early Netra X1 systems.
375-0134Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery BatterySun StorEdge A1000
375-0135Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery BatterySun StorEdge A1000
375-0135-01When a failed controller board is replaced in the A1000 StorEdge Array, it is necessary to first verify the RAID Manager software version being used, the controller firmware level, and the controller memory size. Failure to do so may result in the wrong FRU being installed. This will result in incompatibility between the controller firmware and the RAID Manager software. This can cause LUN's under the A1000 to be inaccessible and cause data access problems.Sun StorEdge A1000
375-0136Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery BatterySun StorEdge A1000
Sun StorEdge N8200
375-0136-01When a failed controller board is replaced in the A1000 StorEdge Array, it is necessary to first verify the RAID Manager software version being used, the controller firmware level, and the controller memory size. Failure to do so may result in the wrong FRU being installed. This will result in incompatibility between the controller firmware and the RAID Manager software. This can cause LUN's under the A1000 to be inaccessible and cause data access problems.Sun StorEdge A1000