Class: 375 | Series: 0
| Part Number | Description | Associated Systems |
|---|---|---|
| 375-0001 | Token Ring Interface (TRI/P) Token Ring Interface (TRI/P) 9-Pin Data Cable (not included and not sold) | Communication Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 375-0002 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Enterprise 10000 Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 |
| 375-0003 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 375-0005 | Dual Single-Ended Ultra SCSI without FCode Dual Single-Ended Ultra SCSI with FCode ( not released ) E450 Internal A-Port and B-Port Cable External HD68 to VHDCI68 Cable, 80 cm External HD68 to VHDCI68 Cable, 2M | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge L9 Sun StorEdge S1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0006 | SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected. | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0007 | Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68 | SCSI Sun StorEdge A1000 |
| 375-0008 | Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68 | SCSI Sun StorEdge Array Controller D1000 |
| 375-0009 | 300/333MHz (Ultra 10) | |
| 375-0009-05 | Ultra 5 and Ultra10 systems may experience fuzzy video, slow booting, and serial port hang when using the external clock source as transfer clock in SYNC mode (X.25). | Sun Ultra 10 Sun Ultra 5 |
| 375-0012 | 32MB SBus NVRAM Board | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 |
| 375-0013 | Dual Single-Ended Ultra SCSI without FCode Dual Single-Ended Ultra SCSI with FCode ( not released ) E450 Internal A-Port and B-Port Cable External HD68 to VHDCI68 Cable, 80 cm External HD68 to VHDCI68 Cable, 2M | SCSI |
| 375-0014 | Dual Differential Ultra SCSI without FCode Dual Differential Ultra SCSI with FCode ( not released ) E450 Internal A-Port and B-Port Cable External HD68 to VHDCI68 Cable, 80 cm External HD68 to VHDCI68 Cable, 2M | SCSI |
| 375-0015 | Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68 | SCSI Sun StorEdge A1000 Sun StorEdge N8200 |
| 375-0015-03 | When a failed controller board is replaced in the A1000 StorEdge Array, it is necessary to first verify the RAID Manager software version being used, the controller firmware level, and the controller memory size. Failure to do so may result in the wrong FRU being installed. This will result in incompatibility between the controller firmware and the RAID Manager software. This can cause LUN's under the A1000 to be inaccessible and cause data access problems. | Sun StorEdge A1000 |
| 375-0016 | Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68 | SCSI Sun StorEdge A1000 |
| 375-0016-03 | When a failed controller board is replaced in the A1000 StorEdge Array, it is necessary to first verify the RAID Manager software version being used, the controller firmware level, and the controller memory size. Failure to do so may result in the wrong FRU being installed. This will result in incompatibility between the controller firmware and the RAID Manager software. This can cause LUN's under the A1000 to be inaccessible and cause data access problems. | Sun StorEdge A1000 |
| 375-0040 | Any FC-AL PCI loop where A5X00 Storage Arrays are directly connected to i) a host using PCI FC100/P initiator card without hub, or ii) other host (dual host) with FC-AL initiator-card is connected to the same loop may experience the following errors as described in BugId 4243157. Sample error messages: Dec 8 05:18:17 name unix: transport rejected (-2) Dec 8 05:18:17 name unix: Dec 8 05:18:17 name unix: WARNING: /pci@4,4000/SUNW, ifp@4/ssd@w2100002037141659,0 (ssd32) Dec 8 05:18:17 name unix: transport rejected (-2) Dec 8 05:18:17 name unix: Dec 8 05:18:18 name unix: ifp0: LIP occurred Dec 8 05:18:18 name unix: ifp0: Loop up Dec 8 05:18:18 name unix: ifp0: Loop reconfigure in progress Dec 8 05:18:18 name unix: ifp0: Loop reconfigure done Dec 8 08:17:41 name unix: ifp0: Loop down Dec 8 08:17:46 name unix: ifp0: LIP reset occurred UPDATE FOR FIN I0541-2: The Corrective Action on FIN I0541-1 provides two different options or solutions to the above mentioned problems as follows: OPTION-1: The FC100/P card is the only Initiator on any one loop where Sun A5x00 Storage Array are direct connected. OPTION-2: A Sun FCAL hub is placed between the FC100/P card(s), and the A5X00 Storage Array. In this case, more than one host-adapter on the same loop, may be used. Due to resistance from the Field over the cost of implementation, OPTION-2 has been removed from the Corrective Action. This option would have required the customer to purchase and connect a hub to the A5x00 Storage Array. The Corrective Action now recommends only OPTION-1 for avoiding this FC100/P card problem. This restriction is advantageous from high-availability/RAS point of view since having each host on a separate loop removes a single point Of failure (SPOF) in Multi Initiator configurations. | Fibre Channel Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra t1 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-0040-01 | FC100/P FC-AL PCI Card (375-0040-02 or below) | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 60 Sun Ultra 80 |
| 375-0040-02 | A host system using the 375-0040-01 or -02 FC-AL PCI card to attach to FC-AL storage, may experience loop errors which affect data access to that storage. In extreme cases, this can result in the host losing its connection to the storage completely. However, it is more common for the loop errors to be intermittent initially, perhaps becoming more frequent over a period of days or a few weeks. The failures are sometimes sensitive to the data pattern on the FC-AL loop, so they are not always reproducible with current diagnostic software. Below are examples of error messages; unix: ifp0: Loop down unix: ifp0: Loop is down: finishing off loop reconfig unix: ifp0: Loop reconfigure done, LIP unix: WARNING: /pci@1f,2000/SUNW,ifp@1/ssd@w21000020370d323b,0 (ssd58): unix: requeue of command fails (fffffffe) - or - unix: WARNING: /pci@1f,2000/SUNW,ifp@1/ssd@w21000020371430cd,0(ssd2): unix: Error for Command: write(10) Error Level: Retryable unix: Requested Block: 4241 Error Block: 4241 unix: Vendor: SEAGATE Serial Number: 9833X17325 unix: Sense Key: Aborted Command unix: ASC: 0x47 (scsi parity error), ASCQ: 0x0, FRU: 0x3 | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 60 Sun Ultra 80 |
| 375-0064 | 375-0088 | |
| 375-0066 | Shipped Speeds: * U5: 270/333MHz U10: 333/360MHz | |
| 375-0066-03 | Reverse capacitor failure in Ultra 5 and Ultra 10 systems. Reverse bias voltage in excess of 20% of manufacturing specification will cause early life failure of the capacitor and, in addition, may cause damage to surrounding PCB or components and/or product functional failure. | Sun Ultra 10 Sun Ultra 5 |
| 375-0071 | Sun Fire V880 DC Power Distribution Board | Power Supplies Sun Fire V880 |
| 375-0073 | Token Ring Interface (TRI/P) Token Ring Interface (TRI/P) 9-Pin Data Cable (not included and not sold) | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0075 | SunPCi 300MHz | |
| 375-0078 | SCSI RAID Controller SRC/P DPT PM3755U2B SmartRAID Millennium DPT DM4050-64 64MB DIMM DPT BB4050 Battery Backup Module DPT BP-0001-001 2.4V Battery DPT SX4055U2-2 SCSI Expansion Module External HD68 to VHDCI68 Cable, 2M (obsolete) External HD68 to VHDCI68 Cable, 2M * (-02 required) E450 Internal 8-Disk Backplane Cable | SCSI Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R Sun Netra 20 |
| 375-0078-01 | Numerous error conditions may result from using the StorEdge SRC/P RAID controller with Firmware Version SM02. | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 |
| 375-0078-02 | Numerous error conditions may result from using the StorEdge SRC/P RAID controller with Firmware Version SM02. | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 |
| 375-0079 | New NVRAM (525-1817) is incompatible with the Ultra 5/10 system board (375-0079), so a new system board (375-0115) was created for the new NVRAM. And, approximately 1,200 system boards (375-0115) with the new NVRAM were incorrectly labeled with the 375-0079 part number. | Sun Ultra 10 Sun Ultra 5 |
| 375-0081 | Sun Ray 1 Assembly/FRU without Stand (380-0299-05 or earlier) 100 MHz microSPARC IIep System Board Power Supply Note: 600-6166 includes stand 370-3918 | Sun Ray |
| 375-0082 | SCSI RAID Controller SRC/P DPT PM3755U2B SmartRAID Millennium DPT DM4050-64 64MB DIMM DPT BB4050 Battery Backup Module DPT BP-0001-001 2.4V Battery DPT SX4055U2-2 SCSI Expansion Module External HD68 to VHDCI68 Cable, 2M (obsolete) External HD68 to VHDCI68 Cable, 2M * (-02 required) E450 Internal 8-Disk Backplane Cable | SCSI |
| 375-0083 | T3 Chassis with Midplane Assembly Chassis Midplane | T3 |
| 375-0084 | There is a possibility that field personnel may have trouble inserting older-style (J9) StorEdge T3 controller FRU's into a newer-style T3 chassis. The J9 controller may require excessive force to insert and may fail to slide all the way into the chassis. This could result in the controller not seating properly and failing to function. | T3 |
| 375-0084-01 | Sun StorEdge T3 (Purple) Arrays shipped prior to General Availability have the potential of experiencing intermittent parity or 'no cache found' errors. Sun StorEdge T3 Arrays with hubs are not supported with controllers earlier than revision J7. Shown below are typical error messages: 0 MBytes Cache Memory Detected 125722 Cache memory parity error detected To recover from the above failure the array would need to be rebooted. The problem results in a loss of data access, not actual data loss. | T3 |
| 375-0085 | Interconnect Board | T3 |
| 375-0086 | 64MB PCI Fast Write Cache | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 60 Sun Ultra 80 |
| 375-0087 | Sun StorEdge Fast Write Cache | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 375-0088 | 375-0064 | |
| 375-0093 | F6800 20MB Fire Link I/O Assembly, Option X4141A cPCI Filler Panel 20MB Fire Link I/O Assembly w Optical Module cPCI Fire Link Optical Module (Paroli) (×2) 20MB Fire Link I/O Assembly/FRU 10MB DIMM (×2) Fire Link I/O Assembly/FRU | I/O Sun Fire 12K / 15K Sun Fire 6800 Switches |
| 375-0094 | E220R DC-DC Converter Circuit DC-DC Converter Interposer Board | Power Supplies Sun Enterprise 220R Sun StorEdge N8200 |
| 375-0094-01 | VRM Interposer board (375-0094-01) can cause intermittent system resets in the Enterprise 220R under high-load conditions. | Allgemein / Unbekannt Sun Enterprise 220R |
| 375-0095 | SunPCi I 400MHz | |
| 375-0096 | System Board UltraSPARCIIe (375-0096-07 or lower) System Board UltraSPARCIIe (375-3061-02 or lower) | Sun Blade 100 |
| 375-0096-01 | SunBlade 100 systems may not auto-restart after a power failure. | Sun Blade 100 |
| 375-0096-04 | Sun Blade 100 onboard graphics video displays may remain white and may not display console output. | Sun Blade 100 |
| 375-0096-05 | Audio Noise from Sunblade 100 system speakers. | Sun Blade 100 |
| 375-0096-07 | This FIN is to inform the field of a part number change on the Sun Blade 100 motherboard. Effective 6/13/2001, the motherboard P/N has been changed from 375-0096-xx to 375-3061-xx. The new motherboard (375-3061-xx) IS backward compatible however, the old motherboard (375-0096-xx) is NOT forward compatible. Both motherboards will be carried as FRU's. | Sun Blade 100 |
| 375-0097 | Single-Channel Single-Ended Ultra/Wide SCSI (PCI) | Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Ultra 10 Sun Ultra 5 |
| 375-0100 | Serial Asychronous Interface (SAI/P) 3.0 NEBS Level-3 8-Port I/O Panel and 78-Pin Cable Data Cable (not included and not sold) | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0103 | Sun Ray 1 Assembly/FRU without Stand (380-0299-06 or later) 100 MHz microSPARC IIep System Board Power Supply Note: 600-6166 includes stand 370-3918 | Sun Ray |
| 375-0104 | Sun Ray 150 Assembly/FRU 100 MHz System Board Philo Board Note: 600-6808 consists of 380-0343, an ethernet cable (370-4232), an AC power adapter (370-4183), and manuals. | Sun Ray |
| 375-0105 | Sun Ray 100 Assembly/FRU 100 MHz microSPARC IIep System Board Note: 600-6809 consists of 380-0344, an Ethernet cable (370-4232), and manuals. | Sun Ray |
| 375-0106 | Right Drive Tray Board (replaces 370-3743) | Sun StorEdge L11000 |
| 375-0107 | Right Drive Sideboard Board (replaces 370-3745) | Sun StorEdge L11000 |
| 375-0108 | Left Drive Tray Board (replaces 370-3742) | Sun StorEdge L11000 |
| 375-0109 | Left Drive Sideboard Board (replaces 370-3744) | Sun StorEdge L11000 |
| 375-0113 | Sun Ray 150 Assembly/FRU 100 MHz System Board Philo Board Note: 600-6808 consists of 380-0343, an ethernet cable (370-4232), an AC power adapter (370-4183), and manuals. | Sun Ray |
| 375-0115 | New NVRAM (525-1817) is incompatible with the Ultra 5/10 system board (375-0079), so a new system board (375-0115) was created for the new NVRAM. And, approximately 1,200 system boards (375-0115) with the new NVRAM were incorrectly labeled with the 375-0079 part number. | Sun Ultra 10 Sun Ultra 5 |
| 375-0116 | Expert3D Lite PCI Frame Buffer (6760B FAB) | Sun Blade 100 T3 |
| 375-0116-01 | Tested | T3 |
| 375-0116-02 | Not Tested | T3 |
| 375-0116-03 | Not Tested | T3 |
| 375-0118 | Compact PCI (cPCI) Dual Channel FC | Fibre Channel Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| 375-0118-01 | Dual Channel Adapter w Firmware x.x Dual Channel Adapter w Firmware 1.13 (Patch 111853-01 ) Dual Channel Adapter w Firmware 1.14.09 (Patch 111853-02 ) Dual Channel Adapter w Firmware 1.14.09 (Patch 111853-03 ) Dual Channel Adapter w Firmware 1.14.10 (Patch 111853-04 ) | Firmware |
| 375-0118-02 | Sun Fire x800 systems are subject to a "panic" problem at boot time when a cPCI Dual FC Network Adapter (FRU or X-option) is installed for the first time. If a customer installs this board and boots the system, they will see panic messages on the console and the boot will fail. However, any subsequent reboots will be successful. This may result in an unnecessary service call. This cPCI board (P/N 370-0118-02) has been shipped with Sun Fire X800 systems and as an X-option. The current estimate is that less than 1000 boards have been installed in systems and 1200 boards are in field stock (FRUs and x-options) as of 7/12/01. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 375-0119 | Dual Differential Ultra SCSI, cPCI (Use for DLT8000) | SCSI Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge A1000 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 |
| 375-0120 | 595-5949 | |
| 375-0121 | 375-3429 | |
| 375-0128 | 375-3014 | |
| 375-0129 | Host Interface Board | Sun Netra E1 |
| 375-0130 | Crypto Accelerator I | Communication Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire V120 Sun Fire V1280 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 60 Sun Ultra 80 |
| 375-0131 | SunPCi II 600MHz, 64MB memory | |
| 375-0131-04 | SunPCi II and SunPCi IIpro cards may not respond after rapid/successive power cycling. | Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0132 | 0MB (500MHz UltraSPARC IIe) | |
| 375-0132-02 | If Lights Out Management (LOM) firmware V3.8 or lower is installed, it may cause fan speed problem on early Netra X1 systems. | |
| 375-0134 | Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Battery | Sun StorEdge A1000 |
| 375-0135 | Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Battery | Sun StorEdge A1000 |
| 375-0135-01 | When a failed controller board is replaced in the A1000 StorEdge Array, it is necessary to first verify the RAID Manager software version being used, the controller firmware level, and the controller memory size. Failure to do so may result in the wrong FRU being installed. This will result in incompatibility between the controller firmware and the RAID Manager software. This can cause LUN's under the A1000 to be inaccessible and cause data access problems. | Sun StorEdge A1000 |
| 375-0136 | Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Battery | Sun StorEdge A1000 Sun StorEdge N8200 |
| 375-0136-01 | When a failed controller board is replaced in the A1000 StorEdge Array, it is necessary to first verify the RAID Manager software version being used, the controller firmware level, and the controller memory size. Failure to do so may result in the wrong FRU being installed. This will result in incompatibility between the controller firmware and the RAID Manager software. This can cause LUN's under the A1000 to be inaccessible and cause data access problems. | Sun StorEdge A1000 |