OSfOM

Class: 501 | Series: 2

<< Back to Series

Part NumberDescriptionAssociated Systems
501-2005501-1725Communication
501-2010Chassis Assembly without Covers, Medium Grey Chassis Assembly with Covers, Medium Grey Top and Bottom Cover, Medium Grey Side Cover, Medium Grey Cover Plug, Medium Grey Foot Backplane Drive Tray Assembly/FRU, Medium Grey Drive Tray Backplane Chassis Subassembly Chassis Power Supply Assembly/FRU, Medium Grey 440 Watt Power Supply Fan Tray Assembly/FRU, Medium Grey 120 × 38 mm Fan, 100CFMSun SPARCstorage Array
501-2015Order Number SMC20-712-330 SPARCstation 20 Model 712 8.4GB Multi-Disk Pack Option 739 (×2) External Active Terminator, HD50 MediaCenter 20 Nameplate Fast SCSI/EThernet FSBE/S Option 1053 (×2) Fast SCSI/EThernet FSBE/S Option 1053 (×2) SunATM-155/MFiber 2.0 Adapter Option 1060 External SCSI Cable, HD50 to HD50, 45 cmEthernet
MediaCenter
SCSI
Sun Enterprise 10000
Sun Enterprise 3000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6000
Sun Enterprise 6500
Sun Ultra 2
Systems Enterprise 4000
Systems Enterprise 5000
501-2018501-2039Graphics
501-2020501-2488Graphics
501-2021Chassis Assembly Chassis Front Bezel Assembly Front EMI Cover SCSI Tray 650 Watt Power Supply Power Key M6 × 14 mm Screw, Foot Top and Bottom Cover Side Cover (obsolete) Side Cover (required if SM81 is installed) Cover Plug Foot 185 CFM Fan Tray Assy, +12Vdc, 4 Amps 6" Fans, 60 CFM @ 1850 RPM @ 0.05" H 2 O 6" Fans, 80 CFM @ 2950 RPM @ 0.15" H 2 O 4.7" Fan, 45 CFM @ 2300 RPM @ 0.9" H 2 O 4-Slot XDBus Backplane #2-56 Nylon Nut Guide Pin M3 × 8 mm Screw (obsolete) M3 × 6 mm Screw Empty Slot Filler PanelSun4d System SPARCserver 1000 and 1000E
501-2027Order Number SMC1000E-614-475 SPARCserver 1000E SPARCstorage Array (Single-Ended SCSI) 2.1GB 7200 RPM Disk Drive FRU Assembly SCSI Interconnect Board Assembly/FRU SCSI Interconnect Board SCSI Interconnect Daughter Board SWIS/S Option 1063 (×6) SunFastEthernet Option 1056 SunFastEthernet Option 1059 External SCSI Cable, HD68 to HD68, 80 cmMediaCenter
501-2028Configured Array Controller Filler Panel Fibre Channel Optical Module Battery Module (obsolete, removed from 501-2552-05) Battery Module Array Controller (40MHz microSPARC II)Fibre Channel
Sun SPARCstorage Array
501-2029Chassis Assembly without Covers, Medium Grey Chassis Assembly with Covers, Medium Grey Top and Bottom Cover, Medium Grey Side Cover, Medium Grey Cover Plug, Medium Grey Foot Backplane Drive Tray Assembly/FRU, Medium Grey Drive Tray Backplane Chassis Subassembly Chassis Power Supply Assembly/FRU, Medium Grey 440 Watt Power Supply Fan Tray Assembly/FRU, Medium Grey 120 × 38 mm Fan, 100CFMSun SPARCstorage Array
501-2031501-2032SPARCstation LX
501-2032501-2233SPARCstation LX
501-2039501-2018Graphics
501-20591MB SIMM 2MB SIMM 4MB SIMM 16MB SIMMMemory
Sun-4 Architecture (Generic)
Sun-4m Architecture
501-2060Memory
Sun-4 Architecture (Generic)
501-2062Quad Ethernet (QEC/S) Quad FastEthernet 1.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4MEthernet
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-20662.1GB SCSI Disk Card with 4x 535MB Disk Drives SCSI Disk Card FRU without Disk Drives 535MB Disk Drive FRU #6-32 x 3/16 Screw, Torx or Bristol Spline 0.096-6 Conner 535MB Disk Drive Conner 535MB Disk Drive Mounting Bracket Seagate 535MB Disk Drive Seagate 535MB Disk Drive Mounting Bracket Single-Ended Active Terminator, HD50Disk (external)
SCSI
501-2069Configured SBus Optical Channel Host Adapter Filler Panel Fibre Channel Optical Module SBus Optical Channel Host Adapter (SOCHA or FC25/S)Fibre Channel
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-2069-05525-1386-02Fibre Channel
501-2069-07525-1386-03Fibre Channel
501-2069-09525-1386-04Fibre Channel
501-2070Order Number SMC1000E-614-475 SPARCserver 1000E SPARCstorage Array (Single-Ended SCSI) 2.1GB 7200 RPM Disk Drive FRU Assembly SCSI Interconnect Board Assembly/FRU SCSI Interconnect Board SCSI Interconnect Daughter Board SWIS/S Option 1063 (×6) SunFastEthernet Option 1056 SunFastEthernet Option 1059 External SCSI Cable, HD68 to HD68, 80 cmMediaCenter
501-20760MB Sun-4/30 CPU FRU (obsolete) 0MB Sun-4/30 CPU FRU (obsolete) 0MB Sun-4/30 CPU FRU 0MB Sun-4/30 CPU FRUSun-4m Architecture
501-2079501-2313SPARCclassic
501-2080Configured Array Controller Filler Panel Fibre Channel Optical Module Battery Module (obsolete, removed from 501-2552-05) Battery Module Array Controller (40MHz microSPARC II)Fibre Channel
Sun SPARCstorage Array
501-2080-05525-1367-02Firmware
501-2080-06525-1367-03Firmware
501-2080-07525-1367-04Firmware
501-2080-08525-1367-04Firmware
501-2080-09525-1367-06Firmware
501-2080-10525-1367-06Firmware
501-2080-11525-1367-07Firmware
501-2080-12525-1437-03Firmware
501-2080-13525-1437-04Firmware
501-2080-14525-1437-05Firmware
501-2080-15525-1437-07Firmware
501-2196xMemory
501-2198I/O PCB (obsolete)SPARCclassic
SPARCstation LX
501-2200501-2262SPARCclassic
501-2208128MB
501-220964MB
501-2221128MB
501-22230MB
501-2232SunVideo BoardSun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-22330MB Sun-4/30 CPU FRU (obsolete) 0MB Sun-4/30 CPU FRU (obsolete) 0MB Sun-4/30 CPU FRU 0MB Sun-4/30 CPU FRUSPARCstation LX
Sun-4m Architecture
501-22422.1GB SCSI Disk Card with 4x 535MB Disk Drives SCSI Disk Card FRU without Disk Drives 535MB Disk Drive FRU #6-32 x 3/16 Screw, Torx or Bristol Spline 0.096-6 Conner 535MB Disk Drive Conner 535MB Disk Drive Mounting Bracket Seagate 535MB Disk Drive Seagate 535MB Disk Drive Mounting Bracket Single-Ended Active Terminator, HD50Disk (external)
SCSI
501-2244501-2066SCSI
501-2245-0332MB
501-2245-0432MB
501-2247-0364MB
501-2247-0464MB
501-2248-03128MB
501-2248-04128MB
501-2253TurboGXplus 8-Bit Frame BufferSun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-22620MB Sun-4/10 CPU FRU 2SPARCclassic
Sun-4m Architecture
501-2269I/O PCBSPARCclassic
SPARCstation LX
501-2273Memory
Sun-4 Architecture (Generic)
501-2275SPARCprinter 20 Printer Board Printer Cable, 10MPrinters
501-2286525-1370-03Sun-4m Architecture
501-22891MB SIMM 2MB SIMM 4MB SIMM 16MB SIMMMemory
Sun-4 Architecture (Generic)
Sun-4m Architecture
501-229664MB
501-2313501-2913SPARCclassic
501-2321256MB
501-2322256MB
501-2323512MB
501-2324SS20 CPU SS20 CPU SS20 CPU 1Sun-4 Architecture (Generic)
501-2325TurboGX 8-Bit Frame BufferSun Enterprise 3000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6000
Sun Enterprise 6500
Sun Ultra 2
Systems Enterprise 4000
Systems Enterprise 5000
501-2326501-2960SPARCclassic
501-2335501-2406
501-23630MB Sun-4/10 CPU FRU P2 Build (obsolete)Sun-4m Architecture
501-2367Order Number SCREEN-100 SPARCstation 5 Model 110 Quad Ethernet Option 1058 PCMCIA Adapter Option 1030 10BASE-T Crossover Cable
501-2406501-2335
501-2412Unprogrammed 40MHz SS1000 Control BoardSun4d System SPARCserver 1000 and 1000E
501-2426Remote LED Display PanelDisk (external)
501-242964MB
501-2430512MB
501-24331MB SIMM 2MB SIMM 4MB SIMM 16MB SIMMMemory
Sun-4 Architecture (Generic)
Sun-4m Architecture
501-2437128MB
501-243864MB
501-2439512MB
501-244864MB
501-2450SunFastEthernet 1.0/1.1 Assembly/FRU SunFastEthernet 1.0/1.1 SBus Card SunFastEthernet Transceiver Card RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M MII to AUI Converter (requires AC power)Ethernet
501-2460Memory
Sun-4 Architecture (Generic)
501-2462Base Assembly (phased in July 1996) M3 × 6 mm Screw, Speaker Assembly Chassis Right Side Vent Panel Foot Right Front Corner Purple Chassis Label Left Front Corner Speaker SCSI I/O Board M2 × 5 mm Screw Bracket Internal SCSI Cable, 485 mm DC Wire Harness Speaker and LED Wire Harness (obsolete) Speaker and LED Wire HarnessSPARCstation 20
SPARCstation 4
SPARCstation 5
501-2470501-2471Memory
SPARCstation 4
Sun-4 Architecture (Generic)
501-2471501-2470Memory
SPARCstation 4
Sun-4 Architecture (Generic)
501-2472501-2508
501-24740MB Sun-4/30 CPU FRU (obsolete) 0MB Sun-4/30 CPU FRU (obsolete) 0MB Sun-4/30 CPU FRU 0MB Sun-4/30 CPU FRUSPARCstation LX
Sun-4m Architecture
501-247932 MB (2 × 16MB DIMMS)Memory
SPARCstation 20
Sun Enterprise 250
Sun Ultra 1
Sun Ultra 2
Sun Ultra 30
Sun Ultra 60
Sun-4 Architecture (Generic)
501-2480CPUSET-2P-512MB 512MB Memory 2× 300MHz Modules 64MB 501-2480 64MB 370-4389 300MHz 501-4849Memory
SPARCstation 20
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 450
Sun Ultra 1
Sun Ultra 2
Sun Ultra 30
Sun Ultra 60
Sun-4 Architecture (Generic)
Systems Telco Netra t 1120
Systems Telco Netra t 1125
501-2486501-4676
501-2487Various disk related errors, including SCSI timeouts, drive offline, and trap 31. The failures are due to the coupled mode/activity dip problem on the KSS crystal.Sun Ultra 2
501-2487-07Auto-eject floppy drive may not eject a diskette from the drive when issued from the "OK" prompt on 200MHz or faster systems.Sun Ultra 2
501-2488501-2020Graphics
501-2502501-2711Graphics
501-2503501-2711Graphics
501-2508501-2472
501-2523SunATM-155/MFiber 2.0/2.1/4.0 SunATM-155/MFiber 2.0/2.1/4.0 SunATM-622/MFiber 2.1/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15MCommunication
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
501-2540501-3025
501-2540-03YesMonitor
Sun-4 Architecture (Generic)
501-2549501-2578
501-2549-03YesMonitor
Sun-4 Architecture (Generic)
501-2552Configured Array Controller Filler Panel Fibre Channel Optical Module Battery Module (obsolete, removed from 501-2552-05) Battery Module Array Controller (40MHz microSPARC II)Fibre Channel
Sun SPARCstorage Array
501-2552-05501-2552 340-2666 370-1426 501-2028 501-2857 501-2080Fibre Channel
501-2553Configured SBus Optical Channel Host Adapter Filler Panel Fibre Channel Optical Module SBus Optical Channel Host Adapter (SOCHA or FC25/S)Fibre Channel
Sun Enterprise 10000
501-2558I/OSun Enterprise 3000
Sun Enterprise 6000
Systems Enterprise 4000
Systems Enterprise 5000
501-2572525-1370-03Sun-4m Architecture
501-2574501-2799
501-2578501-2590
501-2585501-3025
501-25884.2GB Wide SCSI Disk Card with 4x 1.05GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 1.05GB Disk Drive FRU #6-32 x 3/16" Button Screw, Torx or 0.096-6 Bristol 1.05GB Disk Drive, Conner CFP1060E 1.05GB Disk Drive, Conner CFP1080E Conner Mounting Bracket 1.05GB Disk Drive, Seagate ST31200WC Seagate Mounting Bracket Single-Ended Forced Perfect Terminator, HD68Disk (external)
SCSI
501-25894.2GB Wide SCSI Disk Card with 4x 1.05GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 1.05GB Disk Drive FRU #6-32 x 3/16" Button Screw, Torx or 0.096-6 Bristol 1.05GB Disk Drive, Conner CFP1060E 1.05GB Disk Drive, Conner CFP1080E Conner Mounting Bracket 1.05GB Disk Drive, Seagate ST31200WC Seagate Mounting Bracket Single-Ended Forced Perfect Terminator, HD68Disk (external)
SCSI
501-2590501-2928
501-2592Audio Module
501-2599Keyswitch Assembly/FRU LED Board to Backplane Cable Fan LED Board Keyswitch Cable Assembly Key (replaced 330-1651)Racks
Sun Enterprise 3000
Sun Enterprise 3500
Sun Enterprise 4000
Sun Enterprise 4500
Sun Enterprise 5000/6000 Data Center Cabinet
Sun Enterprise 5500
Sun Enterprise 6500
501-2600SCSI Tray Assembly/FRU DC Wire Harness (×2) SCSI Adapter Internal SCSI Cable, 59 cm Internal SCSI Cable, 63 cm 1 Filler Panel Filler Panel Bracket Peripheral Mounting BracketSCSI
Sun Enterprise 4000
Sun Enterprise 4500
Sun Enterprise 5000
Sun Enterprise 5500
Sun Enterprise 6000
Sun Enterprise 6500
501-2603SBus SunISDN-BRI/SBI SBus SunISDN-BRI/SBI (BABT, ETSI-1, and AU-1 approved) RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4MCommunication
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-262264MB SIMM 32MB SIMM 128MB SIMM 64MB SIMMMemory
SPARCstation 20
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 450
Sun Ultra 1
Sun Ultra 2
Sun Ultra 30
Sun Ultra 60
Sun-4 Architecture (Generic)
Systems Telco Netra t 1120
Systems Telco Netra t 1125
501-2634Creator Series 1 (FFB)Sun Ultra 2
501-2646SunFastEthernet 1.0/1.1 Assembly/FRU SunFastEthernet 1.0/1.1 SBus Card SunFastEthernet Transceiver Card RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M MII to AUI Converter (requires AC power)Ethernet
501-2651Configured Array Controller Filler Panel Fibre Channel Optical Module Battery Module Differential Array Controller (40MHz microSPARC II)Fibre Channel
Sun SPARCstorage Array
501-2651-01525-1401-01Firmware
501-2651-02525-1367-06Firmware
501-2651-03525-1367-06Firmware
501-2651-04525-1367-07Firmware
501-2651-05525-1437-03Firmware
501-2651-06525-1437-04Firmware
501-2651-07525-1437-05Firmware
501-2651-08525-1437-07Firmware
501-265264 MB (8 × 8MB DIMMs)Memory
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
501-2653256 MB (8 × 32MB DIMMs)Memory
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
501-2653-01DIMMs are being unnecessarily replaced on Enterprise 10000 servers.Sun Enterprise 10000
501-26541 GB (8 × 128MB DIMMs)Memory
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
501-2654-01DIMMs are being unnecessarily replaced on Enterprise 10000 servers.Sun Enterprise 10000
501-2655Order Number SMC1000E-614-475 SPARCserver 1000E SPARCstorage Array (Single-Ended SCSI) 2.1GB 7200 RPM Disk Drive FRU Assembly SCSI Interconnect Board Assembly/FRU SCSI Interconnect Board SCSI Interconnect Daughter Board SWIS/S Option 1063 (×6) SunFastEthernet Option 1056 SunFastEthernet Option 1059 External SCSI Cable, HD68 to HD68, 80 cmEthernet
MediaCenter
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
501-2664BackplaneSun SPARCstorage Array
501-2665SunATM-155/UTP5 1.0 SunATM-155/UTP5 2.0 RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4MCommunication
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
501-2666501-2674
501-2667Programmed 50MHz SS1000E Control Board 1Sun4d System SPARCserver 1000 and 1000E
501-2670Differential SCSI to Fibre Channel Adapter SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15MFibre Channel
Sun SPARCstorage Array
501-2672256MB
501-2673Unprogrammed 50MHz SS1000E Control Board 1Sun4d System SPARCserver 1000 and 1000E
501-2674501-2666
501-2687FDDI/S SAS Fiber 3.0 HW/SW Assembly FDDI/S SAS Fiber FRU Assembly Network Peripherals FDDI/S SAS Fiber CardCommunication
501-2689FDDI/S DAS Fiber 3.0 HW/SW Assembly FDDI/S DAS Fiber FRU Assembly Network Peripherals FDDI/S DAS Fiber CardCommunication
501-269916-Slot Backplane (obsolete) 16-Slot BackplaneSun Enterprise 6000
501-2702167MHz UltraSPARC ModuleSun Ultra 2
501-2711501-2502Graphics
501-27190MB
501-27200MB
501-2721128MB
501-2722256MB
501-2723128MB
501-2724Power Supply Interface BoardPower Supplies
Sun4d System SPARCcenter 2000 and 2000E
501-273664MB
501-2737128MB
501-2739SunSwift SCSI/Ethernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4MEthernet
SCSI
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge 3120
Sun StorEdge 3310
Sun StorEdge S1
Sun Ultra 2
501-2739-05Enterprise 10000 systems with (SunSwift) Cards could experience intermittent but fatal errors at power up.Sun Enterprise 10000
501-2741SunSwift SCSI/Ethernet SunSwift SCSI/Ethernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4MEthernet
SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V480
Sun Fire V880
Sun Netra 20
Sun Netra t1
Sun StorEdge S1
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
501-2749Graphics I/O BoardSun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
501-276464MB
501-2765128MB
501-27660MB
501-2771Memory
Sun-4 Architecture (Generic)
501-2778501-2779
501-2779501-2778
501-2781LCD DisplaySun SPARCstorage Array
501-2786Configured Array Controller Filler Panel Fibre Channel Optical Module Battery Module Differential Array Controller (40MHz microSPARC II)Fibre Channel
Sun SPARCstorage Array
501-2790Disk Drive Enclosure FRU without Disk Drive Disk Drive Enclosure without Disk Drive Lockbox Disk Drive Cover Assembly M3 × 6 mm Screw Disk Drive Power Supply Assembly M3 × 25 mm Screw (obsolete) M3 × 25 mm Pan-Head Screw Fan Disk Drive DC Power Cable Disk Drive SCSI Interface Card M4 × 10 mm Screw M4 Nut 30 Watt Power Supply LED Cable #4-40M/2-56F Jackscrew Base AssemblyDisk (external)
501-2791Tape Enclosure FRU without Tape Drive Tape Enclosure without Tape Drive Lockbox Tape Drive Cover Assembly M3 × 6 mm Screw Tape Drive Power Supply Assembly M3 × 25 mm Screw (obsolete) M3 × 25 mm Pan-Head Screw Fan Tape Drive DC Power Cable Tape Drive SCSI Interface Card Address Select Cable Address Select Cable M4 × 10 mm Screw M4 Nut 30 Watt Power Supply LED Cable #4-40M/2-56F Jackscrew Base AssemblyRemovable Media
501-2794Order Number SMC1000E-614-460 SPARCserver 1000E SPARCstorage Array (Single-Ended SCSI) 2.1GB 7200 RPM Disk Drive FRU Assembly SCSI Interconnect Board Assembly/FRU SCSI Interconnect Board SCSI Interconnect Daughter Board SWIS/S Option 1063 (×6) SunATM-155/MFiber 2.0 Option 1060 (×4) External SCSI Cable, HD68 to HD68, 80 cmCommunication
MediaCenter
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-2794-08SunATM-155 SBus board replacement may render interface unrecognizable.Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-2795SunATM-155/UTP5 1.0 SunATM-155/UTP5 2.0 RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4MCommunication
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-2795-06SunATM-155 SBus board replacement may render interface unrecognizable.Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-2798501-2802
501-2799501-2803
501-2802501-2811
501-2803501-2799
501-2805128MB
501-280632MB
501-2811501-2802
501-2815501-2816
501-2816501-2815
501-2836501-2854
501-2854501-2855
501-2855501-2994
501-2857SPARCstorage Array Model 210 Chassis Differential SCSI Array Controller (110MHz) Fibre Channel Optical Module Battery Module Differential SCSI to Fibre Channel Adapter Power Supply Assembly/FRUFibre Channel
Sun SPARCstorage Array
501-2860501-2861
501-2861501-2862
501-2861-02YesMonitor
Sun-4 Architecture (Generic)
501-2862501-3002
501-2864SunATM-155/MFiber 2.0/2.1/4.0 SunATM-155/MFiber 2.0/2.1/4.0 SunATM-622/MFiber 2.1/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15MCommunication
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-28716-Slot BackplaneDisk (external)
501-2872Configured Array Controller, Light Grey Filler Panel Fibre Channel Optical Module Battery Module Array Controller, Light Grey (110MHz microSPARC II)Fibre Channel
Sun SPARCstorage Array
501-2872-02Not releasedFirmware
501-2872-03525-1437-03Firmware
501-2872-04525-1437-04Firmware
501-2872-05525-1437-05Firmware
501-2872-06525-1437-07Firmware
501-287516MB SIMM Option SPRN-EC-RAM16 16MB SIMMMemory
Printers
501-289516MB SIMM Option SPRN-E-RAM16 16MB SIMMMemory
Printers
501-289632MB SIMM Option SPRN-E-RAM32 32MB SIMMMemory
Printers
501-289912-Slot BackplaneDisk (external)
501-2900Fan Controller Assembly (Fan Tray Assembly) Fan Controller
501-2902256MB
501-29054MB SIMMMemory
Printers
501-29130MB Sun-4/10 CPU FRU with OBP 2.20SPARCclassic
Sun-4m Architecture
501-2919Order Number SMC-A14-167-500 Ultra 2 Model 2170 SPARCstorage MultiPack, Option 5503 (×2) Single-Ended Forced Perfect Terminator, HD68 SWIS/S, Option 1063 (×2) SunATM-155/MFiber 2.0, Option 1060 SunFastEthernet 2.0, Option 1059 External SCSI Cable, HD68 to HD68, 80 cm 4.2GB 5400 RPM Disk Drive AssemblyEthernet
MediaCenter
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-2922TurboGX 8-Bit Frame BufferSun Enterprise 3000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6000
Sun Enterprise 6500
Sun Ultra 2
Systems Enterprise 4000
Systems Enterprise 5000
501-2924SS20 CPU SS20 CPU SS20 CPU 1Sun-4 Architecture (Generic)
501-2925SM71 SuperSPARC 2.4.5 SM71 SuperSPARC 2.3 SM71 SuperSPARC 2.4.3Sun-4 Architecture (Generic)
501-2928501-2590
501-2928-02YesMonitor
Sun-4 Architecture (Generic)
501-2929Order Number SMC1000E-614-475 SPARCserver 1000E SPARCstorage Array (Single-Ended SCSI) 2.1GB 7200 RPM Disk Drive FRU Assembly SCSI Interconnect Board Assembly/FRU SCSI Interconnect Board SCSI Interconnect Daughter Board SWIS/S Option 1063 (×6) SunFastEthernet Option 1056 SunFastEthernet Option 1059 External SCSI Cable, HD68 to HD68, 80 cmMediaCenter
501-29394-Slot Backplane (1.0" or 1.6" height disk)Sun Enterprise 3000
501-2940SM71 SuperSPARC 2.4.5 SM71 SuperSPARC 2.3 SM71 SuperSPARC 2.4.3Sun-4 Architecture (Generic)
501-2941167MHz UltraSPARC Module (512KB Cache Blackbird)Sun Enterprise 3000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6000
Sun Enterprise 6500
Systems Enterprise 4000
Systems Enterprise 5000
501-2942167MHz UltraSPARC ModuleSun Ultra 2
501-2942-01New Flash PROM firmware allows mixing of differing 167MHz UltraSPARC 2. Otherwise, when an UltraSPARC 2, 167MHz CPU module with CPU revision 2.2, and an UltraSPARC 2, 167MHz CPU module with CPU revision 4.0, are installed in the same Ultra 2 system having an OpenBoot firmware version of 3.1.2 or lower, the default CPU speed reverts to 148MHz.Sun Ultra 2
501-2942-02New Flash PROM firmware allows mixing of differing 167MHz UltraSPARC 2. Otherwise, when an UltraSPARC 2, 167MHz CPU module with CPU revision 2.2, and an UltraSPARC 2, 167MHz CPU module with CPU revision 4.0, are installed in the same Ultra 2 system having an OpenBoot firmware version of 3.1.2 or lower, the default CPU speed reverts to 148MHz.Sun Ultra 2
501-2947Interconnect Board Assembly Vertical Interconnect Board Horizontal Interconnect BoardSun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
501-2948Interconnect Board Assembly Vertical Interconnect Board Horizontal Interconnect BoardSun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
501-2948-06525-1691-02Firmware
501-2948-07525-1691-03Firmware
501-2948-08525-1691-04Firmware
501-2948-09525-1691-05Firmware
501-2948-10525-1691-06Firmware
501-2948-11525-1691-07Firmware
501-2948-12525-1691-08Firmware
501-2951Configured Interface Board FC-AL GBIC Optical Module Interface BoardSun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
501-2951-04525-1689-04Firmware
501-2951-05525-1689-06Firmware
501-2951-06525-1689-07Firmware
501-2951-09525-1689-08Firmware
501-2951-10525-1689-08Firmware
501-2951-11525-1689-09Firmware
501-2951-12525-1689-10Firmware
501-2951-13525-1689-11Firmware
501-2955TurboGXplus 8-Bit Frame BufferSun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Ultra 2
501-2959167MHz UltraSPARC Module (1MB Cache Blackbird)Sun Enterprise 3000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6000
Sun Enterprise 6500
Systems Enterprise 4000
Systems Enterprise 5000
501-2960501-2326SPARCclassic
501-2961SS20 CPU SS20 CPU SS20 CPU 1Sun-4 Architecture (Generic)
501-296664MB
501-2967128MB
501-2968128MB
501-2976CPU/Memory Board - 0MB FRU w/o Module, 83MHz Gigaplane (2MB cache per module)
501-2977n/aSun Enterprise 3000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6000
Sun Enterprise 6500
Systems Enterprise 4000
Systems Enterprise 5000
501-29788-Slot CenterplaneSun Enterprise 4000
Sun Enterprise 5000
Systems Enterprise 4000
Systems Enterprise 5000
501-29808.4 GB Wide SCSI Disk Card with 4x 2.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 2.1GB 7200 RPM Disk Drive FRU #6-32 x 3/16" Button Screw, Torx or 0.096-6 Bristol 2.1GB Disk Drive, IBM DFHS-32160-S2S 2.1GB Disk Drive, Seagate ST32550WC Drive Mounting Bracket Single-Ended Forced Perfect Terminator, HD68MediaCenter
SCSI
501-2981Order Number SMC20-712-330 SPARCstation 20 Model 712 8.4GB Multi-Disk Pack Option 739 (×2) External Active Terminator, HD50 MediaCenter 20 Nameplate Fast SCSI/EThernet FSBE/S Option 1053 (×2) Fast SCSI/EThernet FSBE/S Option 1053 (×2) SunATM-155/MFiber 2.0 Adapter Option 1060 External SCSI Cable, HD50 to HD50, 45 cmEthernet
MediaCenter
Sun Enterprise 10000
Sun Enterprise 3000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6000
Sun Enterprise 6500
Sun Ultra 2
Systems Enterprise 4000
Systems Enterprise 5000
501-2982Configured Array Controller, Light Grey Filler Panel Fibre Channel Optical Module Battery Module Array Controller, Light Grey (110MHz microSPARC II)Fibre Channel
Sun SPARCstorage Array
501-2988Interconnect Board Assembly ( 501-2951 + 370-2303 )Sun StorEdge A5000
501-2989-03540-2989 370-2303 501-3060Sun StorEdge A5200
501-2989-04540-2989 370-2303 501-5202Sun StorEdge A5200
501-2989-05540-2989 370-2303 501-5266Sun StorEdge A5200
501-2994501-2855
501-299564MB
501-2996There is confusion about the front panel status LEDs on Ultra 450 and Enterprise 450 blinking differently on some systems. The NVRAM variable mfg-options sets these systems up as a workstation or server, which controls the front panel LEDs, the system name displayed in the banner, energystar, and watchdog-enable.Boot PROMs
Sun Enterprise 450
Sun-4u Architecture
501-29980MB
501-29990MB