594-2001S2.0 Daughterboard Assembly w/ 2× 2.8GHz CPU and VRMs E4 Stepping
594-20212N Power Supply for 8 Robot ArmsSun StorEdge L8500 Tape Library
594-2022Power Supply For 4-8 Robot ArmsSun StorEdge L8500 Tape Library
594-20232N Power Supply For 4-8 Robot ArmsSun StorEdge L8500 Tape Library
594-2082RAID Fibre Channel Controller, 2GB memory, 4 host ports, LSun StorageTek 6140 Array, RoHS:YL
594-21164GB Short Wave SFP Transceiver, Option XSFP-SW-4GB 4GB Short Wave SFP Transceiver 4-Pack, Option XSFP-SW-4GB-4PK 4GB Short Wave SFP Transceiver,Switches
594-2278Option SG-XTAPDAT72-D2 4 mm DAT 72 Desktop Assembly/FRU: 4 mm DAT 72 Tape Drive Enclosure Power Supply US Power Cord 1 TerminatorSCSI
594-2281Option SG-XTAPDAT72-R-2 1U SCSI Rackmount Tray Assembly, 4 mm DAT 72 Tape Drive, US Power Cord 1 Mounting Rail KitSCSI
594-2282Option SG-XTAPLTO2-D-2 LTO Cleaning Tape LTO2 MediaSCSI
594-2283Option SG-XTAPLTO3-D-2 LTO Cleaning Cartridge LTO3 Media Power CordSCSI
594-2295594-2296Switches
594-2296594-2295Switches
594-23004GB Short Wave SFP Transceiver, Option XSFP-SW-4GB 4GB Short Wave SFP Transceiver 4-Pack, Option XSFP-SW-4GB-4PK 4GB Short Wave SFP Transceiver,Switches
594-2337F371-0875Switches
594-2338594-2339Switches
594-2339594-2340Switches
594-2340594-2339Switches
594-2341594-2342Switches
594-2342594-2341Switches
594-2381S2.0 Daughterboard Assembly w/ 2× 2.4GHz CPU and VRMs E4 Stepping
594-2382Half-Height LTO2 Desktop, Option SG-XTAPLTO2V-D, LTO2 Desktop Assembly/FRU, Half Height Enclosure, HP DW014-60019 LTO2V Drive, HP DW014-60041 US Power Cord, HP 8120-1378 Internal SCSI Cable, HP 0000-0082 Internal ID Cable, HP C7369-61004 Cleaning Cartridge, HP C7978-60001 Data Cartridge, HP C7972-60001Removable Media
594-2383Half-Height LTO2 Rackmount, Option SG-XTAPLTO2V-R, 1U SCSI Rackmount Tray Assembly, LTO2 Drive,Removable Media
594-2384Half-Height LTO2 Drive, Option SG-XTAPLTO2VR-B2, LTO2 Drive,Removable Media
594-24146632 To 8360 Slot Expansion Module (with end rails), L
594-24158360 To 10088 Slot Expansion Module (with end rails), L
594-24166632 To 8360 Slot Expansion Module (without end rails), L
594-2431L500-24 Cartridge SDLT Base Library (Option SG-XLIBL500M-BASE), LSun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
594-2432L500 SDLT 18 Cartridge Upgrade (Option SG-XL500M-18UP)Sun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
594-2433L500 SDLT 44 Cartridge Upgrade (Option SG-XL500M-44UP), LSun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
594-2434L500 SDLT 33 Cartridge Upgrade (Option SG-XL500M-33UP)Sun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
594-2435L500 SDLT Cartridge Expansion Module (CEM)/(Option SG-XL500M-CARTEXP), LSun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
594-2436L500 SDLT Drive Expansion Module (DEM) (Option SG-XL500M-DREXP), LSun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
594-2437L500 SDLT 4 Cartridge Magazine, LRemovable Media
594-2438Robot Arm Assembly (Set of 4)
594-2466375-3383 [F]Sun Enterprise 10000
594-2470Sun Rack 900-38, w/o Power Distribution, Option SR9-2XKL038A-IP, [S] Sun Rack 900-38, w/o Power Distribution, Option SR9-2KL038A-IP, [S] Sun Rack 900-38, w/ Power Distribution, Option SR9-2XKM038A-IP, [S] Sun Rack 900-38, w/ Power Distribution, Option SR9-2KM038A-IP, [S] Sun Rack 900-38, w/o Power Distribution, SR-2938A, [S]Racks
594-2471Sun Rack 1000-38, w/o Power Distribution, Option SRK-2XBC038A-IP [S] Sun Rack 1000-38, w/o Power Distribution, Option SRK-2BC038A-IP [S] Sun Rack 1000-38, w/ Power Distribution, Option SRK-2XRS038A-IP [S] Sun Rack 1000-38, w/ Power Distribution, Option SRK-2RS038A-IP [S] Sun Rack 1000-38, w/o Power Distribution, Option SR-21038A [S]Racks
594-2474594-0609Switches
594-2481Sun Rack 1000-42, w/ 32A Power Distribution, Option SR2-1042-X32TPL Sun Rack 1000-42, w/ 32A Power Distribution, Option SR2-1042-32TPL Sun Rack 1000-42, w/ 60A Power Distribution, Option SR2-1042-X60TPL Sun Rack 1000-42, w/ 60A Power Distribution, Option SR2-1042-60TPL Sun Rack 1000-42, w/o Power Distribution, Option SR2-1042A Sun Rack 1000-42, w/ 24A Power Distribution, Option SR2-1042-XPDS Sun Rack 1000-42, w/ 24A Power Distribution, Option SR2-1042-PDSRacks
594-25042GB Compact Flash Option XCP3000-CF-2GB 2GB Compact Flash 2GB Memory Option XCP3020-MEM-2GB [S] 1GB DIMM 4GB Memory Option XCP3020-MEM-4GB 2GB DIMMSystems Telco Netra CP3020
594-25052GB Compact Flash Option XCP3000-CF-2GB 2GB Compact Flash 2GB Memory Option XCP3020-MEM-2GB [S] 1GB DIMM 4GB Memory Option XCP3020-MEM-4GB 2GB DIMMSystems Telco Netra CP3020
594-25062GB Memory Option XCP3010-MEM-2GB 1GB DIMMSystems Telco Netra CP3010
594-250740GB PMC Disk Drive Option X4010A [S] 40GB PMC Disk Drive Assembly 73GB 10000 RPM SAS Disk Drive Option X4013A [S] 73GB 10000 RPM SAS Disk Drive Assembly Fujitsu 73GB 10000 RPM SAS Disk Drive Seagate 73GB 10000 RPM SAS Disk Drive 73GB 10000 RPM SAS Disk Drive Assembly Seagate 73GB 10000 RPM SAS Disk Drive Hitachi 73GB 10000 RPM SAS Disk DriveSystems Telco Netra CP3010
Systems Telco Netra CP3020
594-251240GB PMC Disk Drive Option X4010A [S] 40GB PMC Disk Drive Assembly 73GB 10000 RPM SAS Disk Drive Option X4013A [S] 73GB 10000 RPM SAS Disk Drive Assembly Fujitsu 73GB 10000 RPM SAS Disk Drive Seagate 73GB 10000 RPM SAS Disk Drive 73GB 10000 RPM SAS Disk Drive Assembly Seagate 73GB 10000 RPM SAS Disk Drive Hitachi 73GB 10000 RPM SAS Disk DriveSystems Telco Netra CP3020
594-2526Sun Rack 900-38, w/o Power Distribution, Option SR9-2XKL038A-IP, [S] Sun Rack 900-38, w/o Power Distribution, Option SR9-2KL038A-IP, [S] Sun Rack 900-38, w/ Power Distribution, Option SR9-2XKM038A-IP, [S] Sun Rack 900-38, w/ Power Distribution, Option SR9-2KM038A-IP, [S] Sun Rack 900-38, w/o Power Distribution, SR-2938A, [S]Racks
Sun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
Sun StorageTek L500 Tape Library, RoHS:YL
594-2527Sun Rack 900-36N, w/o Power Distribution, Option SR9-2XMD036A-IP [S] Sun Rack 900-36N, w/o Power Distribution, Option SR9-2MD036A-IP [S] Sun Rack 900-36N, w/ Power Distribution, Option SR9-2XBM036A-IP [S] Sun Rack 900-36N, w/ Power Distribution, Option SR9-2BM036A-IP [S] Sun Rack 900-36N, w/o Power Distribution, Option SR-2936NA, [S]Racks
594-2532S3.0 Daughterboard Assembly w/2× 2.4GHz CPU and VRMs E6 Stepping, L
594-2534Sun Rack 1000-42, w/o Power Distribution, Option SR-21042A, [S] Sun Rack 1000-42, w/ Power Distribution, Option SRK-2AZ042A-IP [S] Sun Rack 1000-42, w/ Power Distribution, Option SRK-2XAZ042A-IP [S]Racks
Sun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
Sun StorageTek L500 Tape Library, RoHS:YL
594-2535Sun Rack 1000-38, w/o Power Distribution, Option SRK-2XBC038A-IP [S] Sun Rack 1000-38, w/o Power Distribution, Option SRK-2BC038A-IP [S] Sun Rack 1000-38, w/ Power Distribution, Option SRK-2XRS038A-IP [S] Sun Rack 1000-38, w/ Power Distribution, Option SRK-2RS038A-IP [S] Sun Rack 1000-38, w/o Power Distribution, Option SR-21038A [S]Racks
Sun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
Sun StorageTek L500 Tape Library, RoHS:YL
594-2556Sun Rack 900-36N, w/o Power Distribution, Option SR9-2XMD036A-IP [S] Sun Rack 900-36N, w/o Power Distribution, Option SR9-2MD036A-IP [S] Sun Rack 900-36N, w/ Power Distribution, Option SR9-2XBM036A-IP [S] Sun Rack 900-36N, w/ Power Distribution, Option SR9-2BM036A-IP [S] Sun Rack 900-36N, w/o Power Distribution, Option SR-2936NA, [S]Racks
594-2558Filler Panel Kit, Option X6826A-2, [S] 1RU Filler Panel, 2RU Filler Panel, 4RU Filler Panel,Racks
Sun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
Sun StorageTek L500 Tape Library, RoHS:YL
594-2564Sun Rack 1000-42 HVAC Air Duct, Option/FRU X9422A-2 HVAC InstallationRacks
594-2565Sun Rack 1000-38, w/ 32A Power Distribution, Option SR2-21038-X32TPL [S] Sun Rack 1000-38, w/ 16/20A Power Distribution, Option SR2-21038-XPDS [S] Sun Rack 1000-38, w/ 32A Power Distribution, Option SR2-21038-32TPL Sun Rack 1000-38, w/ 60A Power Distribution, Option SR2-21038-X60TPL [S] Sun Rack 1000-38, w/ 60A Power Distribution, Option SR2-21038-60TPL Sun Rack 1000-38, w/ 16/20A Power Distribution, Option SR2-21038-PDS [S] Sun Rack 1000-38, w/o Power Distribution, Option SR2-21038A [S]Racks
594-2566Sun Rack 1000-42, w/ 32A Power Distribution, Option SR2-21042-X32TPL, [S] Sun Rack 1000-42, w/ 32A Power Distribution, Option SR2-21042-32TPL, [S] Sun Rack 1000-42, w/ 60A Power Distribution, Option SR2-21042-X60TPL, [S] Sun Rack 1000-42, w/ 60A Power Distribution, Option SR2-21042-60TPL [S] Sun Rack 1000-42, w/o Power Distribution, Option SR2-21042A, [S] Sun Rack 1000-42, w/o Dual 60A Power, SR2-21042-X60A60, [S] Sun Rack 1000-42, w/o Dual 60A Power, SR2-21042-60A60, [S]Racks
594-2567StorEdge A1000/D1000 Mounting Kit, Option X6838A-2, [S] Left Rail, Right Rail, Tray, Adapter Rail, A1000/D1000 Rack Mount Installation ManualRacks
594-2568StorEdge D240 Mounting Kit, Option X6839A-2, [S] Left Rail, Right Rail, Adapter, Front Mounting Bracket, D240 Rack Mount Installation ManualRacks
594-2569Sun Rack 1000-38, w/ 32A Power Distribution, Option SR2-21038-X32TPL [S] Sun Rack 1000-38, w/ 16/20A Power Distribution, Option SR2-21038-XPDS [S] Sun Rack 1000-38, w/ 32A Power Distribution, Option SR2-21038-32TPL Sun Rack 1000-38, w/ 60A Power Distribution, Option SR2-21038-X60TPL [S] Sun Rack 1000-38, w/ 60A Power Distribution, Option SR2-21038-60TPL Sun Rack 1000-38, w/ 16/20A Power Distribution, Option SR2-21038-PDS [S] Sun Rack 1000-38, w/o Power Distribution, Option SR2-21038A [S]Racks
594-2570Netra t 1400 Mounting Kit, Option X6846A-2 [S] Front Bracket Rear Bracket Nut Plate Bracket Left Adapter Bracket Right Adapter bRACKET Rack Slide Netra t 1400 Rack Mount Installation ManualRacks
594-2590Sun Rack 1000-42, w/ 32A Power Distribution, Option SR2-21042-X32TPL, [S] Sun Rack 1000-42, w/ 32A Power Distribution, Option SR2-21042-32TPL, [S] Sun Rack 1000-42, w/ 60A Power Distribution, Option SR2-21042-X60TPL, [S] Sun Rack 1000-42, w/ 60A Power Distribution, Option SR2-21042-60TPL [S] Sun Rack 1000-42, w/o Power Distribution, Option SR2-21042A, [S] Sun Rack 1000-42, w/o Dual 60A Power, SR2-21042-X60A60, [S] Sun Rack 1000-42, w/o Dual 60A Power, SR2-21042-60A60, [S]Racks
594-2604Sun Rack 1000-42 Rear Door with Fan, Option X9421A-2, Sun Rack 1000-42 Rear Door with Fan, Option 9421A-2, 10A 90° IEC 320 C13 to 90° IEC 320 Sheet E Power Cord, Door Frame, Chimney, Fan Module, Sun Rack Fan Door Installation and ServiceRacks
594-26172.4GHz Dual Core Opteron 180 Socket 939,Sun Ultra 2
594-2624Sun Rack 1000-38, w/ 32A Power Distribution, Option SR2-21038-X32TPL [S] Sun Rack 1000-38, w/ 16/20A Power Distribution, Option SR2-21038-XPDS [S] Sun Rack 1000-38, w/ 32A Power Distribution, Option SR2-21038-32TPL Sun Rack 1000-38, w/ 60A Power Distribution, Option SR2-21038-X60TPL [S] Sun Rack 1000-38, w/ 60A Power Distribution, Option SR2-21038-60TPL Sun Rack 1000-38, w/ 16/20A Power Distribution, Option SR2-21038-PDS [S] Sun Rack 1000-38, w/o Power Distribution, Option SR2-21038A [S]Racks
594-2626594-2627 3Switches
594-2627852-2339 4Switches
594-2628594-2629 2Switches
594-2629594-2116Switches
594-2630371-4576 2Switches
594-2632594-2633Switches
594-2633594-2639Switches
594-2639594-2633Switches
594-2640594-3995Switches
594-2650Option SG-XSWM6140-ZP-Z, L 0-Port 6140 SwitchSwitches
594-2651Option SG-XSWM6140-RKZP-Z, L Domestic Fabricenter Rack with 0-Port 6140 SwitchSwitches
594-2652Option SG-XSWM6140-RKZI-Z, L International Fabricenter Rack with 0-Port 6140 SwitchSwitches
594-2653Option SG-XSWMD-MOD-2G-Z, L [S] 4-Port Fibre Module w/o SFP, LSwitches
594-2654McDATA Eclipse 1620, Option SG-XSWMD1620-12-Z McDATA Eclipse 1620 Switch Assembly/FRU, L Ship Kit Rack Mount KitSwitches
594-26552.6GHz Dual Core Opteron 285 Option,
594-26562.4GHz Dual Core Opteron 280 Option,
594-26572.2GHZ Dual Core Opteron 275 Option,
594-26582.8GHz Opteron 254 Option,
594-26592.4GHz Opteron 250 Option,
594-26602.0GHz Opteron 246 Option,
594-26668-Slot LTO2 Autoloader Base, Option SG-XAUTO8LTO2-C2 8-Slot LTO2 Autoloader FRU, Quantum EC-LF7CA-HW 8-Slot LTO2 Autoloader Base, Quantum EC-LL7AA-HW Ultra-320 SCSI Cable, 2M, Quantum 17-80192-01 Power Cord, 1.9M, Quantum 17-80187 1 LVD/SE Terminator, Quantum 0455213 Rackmount Kit, Quantum 70-87053-01 2Systems StorEdge C2 Tape Autoloader
594-266716-Slot LTO2 Autoloader Base, Option SG-XAUTO16LTO2-C2 16-Slot LTO2 Autoloader Base, Quantum EC-L27AA-HW Ultra-320 SCSI Cable, 2M, Quantum 17-80192-01 Power Cord, 1.9M, Quantum 17-80187 1 LVD/SE Terminator, Quantum 0455213 Rackmount Kit, Quantum 70-87053-01 2Systems StorEdge C2 Tape Autoloader
594-26688-Slot SDLT600 Autoloader, Option SG-XAUTO8SDLT6-C2Z 8-Slot SDLT600 Autoloader FRU, Quantum EC-SF2CA-HW 8-Slot SDLT600 Autoloader Base, Quantum EC-SF2CA-HW 8-Slot SDLT600 Autoloader Base, Quantum ER-SF2CA-HW Ultra-320 SCSI Cable, 2M, Quantum 17-80192-01 Power Cord, 1.9M, Quantum 17-80187 1 LVD/SE Terminator, Quantum 0455213 Rackmount Kit, Quantum 70-87053-01 2Systems StorEdge C2 Tape Autoloader
594-266916-Slot SDLT600 Autoloader, Option SG-XAUTO16SDL6-C2Z 16-Slot SDLT600 Autoloader Base Ultra-320 SCSI Cable, 2M, Quantum 17-80192-01 Power Cord, 1.9M, Quantum 17-80187 1 LVD/SE Terminator, Quantum 0455213 Rackmount Kit, Quantum 70-87053-01 2Systems StorEdge C2 Tape Autoloader
594-2676Option SG-XTAPSDLT600-D-Z HD68 LVD/SE Terminator Power Cord SDLT Cleaning Tape SDLT2 Media SDLT600 FRU Assembly, Enclosure SCSI ID Switch LVD/SE Host Bezel, Quantum SDLT600 DriveRemovable Media
594-2682Wago DC Connector Set (10 pack),
594-2683Air Filter 10-Pack,
594-26862 GB (2 × 1GB DDR1-400 Registered ECC DIMMs), L
594-26874 GB (2 × 2GB DDR1-400 Registered ECC DIMMs), L
594-2705Cabinet Hold Down Kit,Sun Fire E20K, RoHS:YL
Sun Fire E25K
594-2706Cable Management Kit,Sun Fire E20K, RoHS:YL
Sun Fire E25K
594-2802DAT 72 Tape Drive ( Option X5882AZ [S] ) 36-72GB 4 mm DAT 72 Assembly/FRU Media Tray Sled 36-72GB 4 mm DAT 72Sun StorEdge D2
594-2804DVD-ROM Assembly/FRU ( Option X5883AZ [S] ) DVD-ROM Assembly Media Tray Sled 16x ATAPI DVD-ROM, Medium GreySun StorEdge D2
594-2863594-2864Switches
594-2864594-2863Switches
594-2928XSFP-LW-4GB-Z 2 4Gbps 4KM Long Wave SFP,Switches
594-2929XSFP-LW-4GB-4PK-Z 2 4Gbps 4KM Long Wave SFP,Switches
594-2930XSFP-ELW-4GB-Z 2 4Gbps 10KM Long Wave SFP,Switches
594-2941S3.0 Daughterboard Assembly w/2× 2.4GHz CPU and VRMs E4 Stepping, L
594-2942S3.0 Daughterboard Assembly w/2× 2.6GHz CPU and VRMs E4 Stepping, L
594-2943S3.0 Daughterboard Assembly w/2× 2.8GHz CPU and VRMs E4 Stepping, L
594-2944S3.0 Daughterboard Assembly w/2× 3.0GHz CPU and VRMs E4 Stepping, L
594-2946S3.0 Daughterboard Assembly w/2× Dual Core 2.6GHz CPU and VRMs E6 Stepping, L
594-2971Option SG-XTAPSDLT6-R-Z 300-600GB SDLT600 Tape Drive FRU, 2U Enclosure FRU, 230 Watt Power Supply Dummy Tape Drive US Power Cord Mounting Rail Kit HD68 LVD/SE Terminator Data Cartridge Cleaning Cartridge SDLT600 Documentation CD , Quantum 81-81210-03 2U Rackmount Documentation CD , Quantum 81-81342-01Removable Media
594-2972Option SG-XTAPLTO3-R-Z 400-800GB LTO3 Tape Drive FRU, 2U Enclosure FRU, 230 Watt Power Supply Dummy Tape Drive US Power Cord Mounting Rail Kit HD68 LVD/SE Terminator Data Cartridge Cleaning Cartridge LTO3 Documentation CD , HP Q1530-11001 2U Rackmount Documentation CD , Quantum 81-81342-01Removable Media