Class: 501 | Series: 3
| Part Number | Description | Associated Systems |
|---|---|---|
| 501-3001 | SM71 SuperSPARC 2.4.5 SM71 SuperSPARC 2.3 SM71 SuperSPARC 2.4.3 | Sun-4 Architecture (Generic) |
| 501-3002 | 501-2862 | |
| 501-3002-02 | Yes | Monitor Sun-4 Architecture (Generic) |
| 501-3008 | 501-3009 | |
| 501-3008-03 | Yes | Monitor Sun-4 Architecture (Generic) |
| 501-3009 | 501-3010 | |
| 501-3010 | 501-3009 | |
| 501-3019 | SunVideo Board | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-3021 | SPARCstorage Array Model 210 Chassis Differential SCSI Array Controller (110MHz) Fibre Channel Optical Module Battery Module Differential SCSI to Fibre Channel Adapter Power Supply Assembly/FRU | Fibre Channel Sun SPARCstorage Array |
| 501-3021-02 | Not released | Firmware |
| 501-3021-03 | 525-1437-03 | Firmware |
| 501-3021-04 | 525-1437-04 | Firmware |
| 501-3021-05 | 525-1437-05 | Firmware |
| 501-3021-06 | 525-1437-07 | Firmware |
| 501-3023 | 501-4325 | I/O |
| 501-3024 | Configured Array Controller Filler Panel Fibre Channel Optical Module Battery Module Differential Array Controller (110MHz microSPARC II) | Fibre Channel Sun SPARCstorage Array |
| 501-3025 | 501-2585 | |
| 501-3025-02 | Yes | Monitor Sun-4 Architecture (Generic) |
| 501-3027 | SunATM-155/UTP 3.0/4.0 SunATM-155/MFiber 3.0/4.0 SunATM-622/MFiber 3.0/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3028 | SunATM-155/UTP 3.0/4.0 SunATM-155/MFiber 3.0/4.0 SunATM-622/MFiber 3.0/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3029 | SunATM-155/UTP 3.0/4.0 SunATM-155/MFiber 3.0/4.0 SunATM-622/MFiber 3.0/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3034 | 256MB | |
| 501-3035 | 256MB | |
| 501-3036 | 128MB | |
| 501-3037 | 512MB | |
| 501-3038 | 128MB | |
| 501-3039 | 256MB | |
| 501-3041 | 200MHz UltraSPARC Module | Sun Ultra 2 |
| 501-3041-05 | Ultra 2 200MHz UltraSPARC CPU modules fail with SRAM and writeback data parity errors. | Sun Ultra 2 |
| 501-3050 | 16-Slot Backplane (obsolete) 16-Slot Backplane | Sun Enterprise 6000 |
| 501-3051 | 64MB | |
| 501-3052 | 256MB | |
| 501-3059 | 501-3103 | |
| 501-3060 | Configured FC-AL SBus Card <=501-2989-03 FC-AL GBIC Optical Module FC-AL SBus Card | Fibre Channel Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-3060-02 | 525-1690-01 | Firmware |
| 501-3060-03 | 525-1690-01 | Firmware |
| 501-3060-04 | 525-1690-02 | Firmware |
| 501-3060-05 | 525-1690-04 | Firmware |
| 501-3060-06 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 |
| 501-3081 | Cardcage Assembly Cardcage Chassis Backplane Spacer Assembly | Sun Netra 150 / E150 |
| 501-3082 | 0MB Ultra Enterprise 1 Model 170 System Board | Sun Netra 150 / E150 |
| 501-3089 | System Controller System Controller | Sun Netra 150 / E150 Sun Netra 150 / Ultra Enterprise 150 |
| 501-3100 | DC Power Distribution Board | Power Supplies Sun Enterprise 450 Sun Ultra 45 |
| 501-3103 | 501-3059 | |
| 501-3104 | System Board to Controller Board Adapter | Sun Netra 150 / E150 |
| 501-3107 | 256MB | |
| 501-3108 | Tape Enclosure FRU without Tape Drive Lower Enclosure, Dark Purple Lockbox Tape Drive Cover Assembly, Medium Grey M3 × 6 mm Screw Tape Drive Power Supply Assembly M3 × 25 mm Screw (obsolete) M3 × 25 mm Pan-Head Screw Fan Tape Drive DC Power Cable Tape Drive SCSI Interface Card Address Select Cable M4 × 10 mm Screw M4 Nut 30 Watt Power Supply LED Cable #4-40M/2-56F Jackscrew Base Assembly | Removable Media |
| 501-3109 | 501-3111 | Monitor Sun-4 Architecture (Generic) |
| 501-3111 | 501-3134 | |
| 501-3113 | 18.2 GB Wide SCSI Disk Card with 2x 9.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 9.1GB 7200 RPM Disk Drive FRU 9.1GB Disk Drive, IBM DDRS-39130 9.1GB Disk Drive, Fujitsu MAB3091SC 9.1GB Disk Drive, Seagate ST39173WC 9.1GB Disk Drive, Fujitsu MAE3091LC 9.1GB Disk Drive, IBM DNES-309170 | SCSI Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-3113-02 | At system power up, the disk board (501-3113-02) does not turn on. This problem may be seen in the field if one of the following two scenario's occur: (1) a disk board is added to a system with a pre-existing disk board or (2) a system is upgraded by adding other modules (CPU, I/O boards, etc). POST will fail with 'SCSI_VDD' error message in DIAG mode. | Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-3128 | Removable Media Backplane | Sun Enterprise 450 |
| 501-3129 | Creator3D Series 1 (FFB) 24-Bit Frame Buffer | Firmware Sun Ultra 2 |
| 501-3132 | Various disk related errors, including SCSI timeouts, drive offline, and trap 31. The failures are due to the coupled mode/activity dip problem on the KSS crystal. | Sun Ultra 2 |
| 501-3132-11 | A tilted second SBus connector on some Ultra 1 and Ultra 2 systems does not allow installation of SBus cards. | Sun Ultra 2 |
| 501-3132-12 | Ultra 2 Model 1300 UPA Bus Terminator Module recommended on uni-processor models. An unterminated UPA bus may exhibit noise problems in very high intensity UPA bus activity applications. Symptoms may include CPU ECache data parity errors, ECC errors, asynch data errors or hangs. | Sun Ultra 2 |
| 501-3132-13 | Auto-eject floppy drive may not eject a diskette from the drive when issued from the "OK" prompt on 200MHz or faster systems. | Sun Ultra 2 |
| 501-3134 | 501-3111 | Monitor Sun-4 Architecture (Generic) |
| 501-3136 | 64MB SIMM 32MB SIMM 128MB SIMM 64MB SIMM | Memory Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun StorEdge N8200 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-3137 | 128MB | |
| 501-3139 | 0MB Ultra 30 System Board | Systems Telco Netra t 1100 |
| 501-3141 | 0MB CPU FRU | |
| 501-3142 | Load Board (required in all unused slots) | Sun Enterprise 6000 Sun Enterprise 6500 |
| 501-3142-01 | Ultra Enterprise E6000 & E6500 system Load Boards can be susceptible to fatal resets. | Sun Enterprise 6500 |
| 501-3809 | System Board Bracket with Fan | Systems Telco Netra t 1120 Systems Telco Netra t 1125 |