Class: 370 | Series: 4
| Part Number | Description | Associated Systems |
|---|---|---|
| 370-4003 | Rear Power Input Filler Panel Front Power Input Filler Panel Rear Empty Drawer Filler Panel Front Empty Drawer Filler Panel cPCI Filler Panel (replaced by 340-7367 and 340-7368) cPCI Rear Filler Panel (fails EMI - use 370-4003) cPCI Front Filler Panel (fails EMI - use 370-4003) | Sun Netra CT 410 Sun Netra CT 810 |
| 370-4011 | 90° IEC 320 - no description available, Japan | |
| 370-4012 | Sun Fire E20K Assy, E20K-BASE-2 Rev 50 (see 602-3043) Sun Fire E25K Assy, E25K-BASE-2 Rev 50 (see 602-3044) Sun Fire E20K Assy, E20K-BASE-2 Rev 51 (see 602-3291) * Sun Fire E25K Assy, E25K-BASE-2 Rev 51 (see 602-3292) * System Expander Assembly System Expander Board FRU ** System Expander Board FRU System Expander DIMM Front Door Rear Door Power Cabinet Assembly Dual AC Input 48 Volt Output Power Supply Logic Centerplane Logic Centerplane Fan Tray Frame Manager Frame Manager Extension, 250 mm, | Racks Sun Fire 12K / 15K |
| 370-4031 | Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973) | Sun Fire 280R |
| 370-4032 | 9840 Media, Option SG-XMED9840-20 9840 Media 20 Pack | Removable Media Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L6000 Sun StorEdge L7 Sun StorEdge L700 |
| 370-4033 | 9840 Cleaning Cartridge, Option SG-XMED9840CL-5 9840 Cleaning Cartridge 5 Pack | Removable Media Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L6000 Sun StorEdge L7 Sun StorEdge L700 |
| 370-4034 | 9840 Media Magazine, holds 5 cartridges (Option SG-XMEDCART-1MAG) | Sun StorEdge L180 Sun StorEdge L7 Sun StorEdge L700 |
| 370-4035 | StorEdge Network FC Switch-8 and StorEdge Network FC Switch-16 products installed in a Storage Area Network (SAN) configuration must have the proper level of firmware installed for proper operation. All switches in the SAN must contain matching firmware versions. Failure to verify and install the correct switch firmware when installing or replacing switches in a SAN can cause the switch to fail. It is important that the firmware of existing switches in a SAN and any replacement switch be checked for compatibility when installing a new switch into the SAN configuration. | Fibre Channel Sun StorEdge 3900/6900 Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4035-01 | StorEdge Network FC Switch-8 and StorEdge Network FC Switch-16 products installed in a Storage Area Network (SAN) configuration must have the proper level of firmware installed for proper operation. All switches in the SAN must contain matching firmware versions. Failure to verify and install the correct switch firmware when installing or replacing switches in a SAN can cause the switch to fail. | Sun StorEdge 3900/6900 |
| 370-4035-02 | User logins to a freshly installed SANSurfer GUI on November 25, 2001 or later may fail. The login for a pre-installed GUI might also fail after that date if no changes have been made to the user account. When customers are unable to login to the SANSurfer application, then the immediate impact is that they will not be able to use any SAN management utilities. Here is the failure message which displays on the console: "Login Failed" - Login Failure as user expires on 11/25/01. | Sun StorEdge 3900/6900 |
| 370-4035-03 | User logins to a freshly installed SANSurfer GUI on November 25, 2001 or later may fail. The login for a pre-installed GUI might also fail after that date if no changes have been made to the user account. When customers are unable to login to the SANSurfer application, then the immediate impact is that they will not be able to use any SAN management utilities. Here is the failure message which displays on the console: "Login Failed" - Login Failure as user expires on 11/25/01. | Sun StorEdge 3900/6900 |
| 370-4038 | Netra xt 600 DC FRU/Option 996 Netra xt 600 DC Chassis 8-Slot 5.0V 32-Bit PCI Backplane DC Input Power Supply PCI SIC Connector Board Host to Expansion Chassis Cable PCI HIC Host Board Wago DC Connector (×4) Wago DC Connector Strain Relief (×4) Wago DC Connector Opening Lever 19" Rack Mount Kit PCI Filler Panel | |
| 370-4039 | Netra t 1405 AC Chassis Assembly Netra t 1400 DC Chassis Assembly 125 Watt DC-DC Converter with Fan Ultra 80 System Board Fan Assembly Ultra 80 System Board Shroud Assembly Chassis Assembly Removable Media SCSI Adapter Fan Fan Control Board Power Distribution Backplane Assembly LED/Alarm Cable LED/Motherboard Cable Power Switch and Cable LED Board Switch and LED Cover Disk Bay Assembly (1.0" or 1.6" height) Disk Bay Power Cable Removable Media Mounting Bracket Fan Cover Removable Media Cover PCI Slot Filler Panel Removable Media SCSI Cable Removable Media Power Cable Top Cover | Sun Netra t 1400 Sun Netra t 1400/1405 Sun Netra t 1405 Server |
| 370-4040 | Netra t 1405 AC Chassis Assembly Netra t 1400 DC Chassis Assembly 125 Watt DC-DC Converter with Fan Ultra 80 System Board Fan Assembly Ultra 80 System Board Shroud Assembly Chassis Assembly Removable Media SCSI Adapter Fan Fan Control Board Power Distribution Backplane Assembly LED/Alarm Cable LED/Motherboard Cable Power Switch and Cable LED Board Switch and LED Cover Disk Bay Assembly (1.0" or 1.6" height) Disk Bay Power Cable Removable Media Mounting Bracket Fan Cover Removable Media Cover PCI Slot Filler Panel Removable Media SCSI Cable Removable Media Power Cable Top Cover | Sun Netra t 1400 Sun Netra t 1400/1405 Sun Netra t 1405 Server |
| 370-4041 | CPU Fan Tray Assembly 120 mm Fan (×3) (replaced 370-2292) | Sun Enterprise 450 |
| 370-4045 | Enterprise Services FDDI/S 5.0 FRU Network Peripherals FDDI/S SAS Fiber Card 1 Network Peripherals FDDI/S DAS Fiber Card 2 | Communication Sun Ultra 2 |
| 370-4046 | Enterprise Services FDDI/S 5.0 FRU Network Peripherals FDDI/S SAS Fiber Card 1 Network Peripherals FDDI/S DAS Fiber Card 2 | Communication Sun Ultra 2 |
| 370-4055 | Processor Cabinet Logo Side Panel Sun Side Panel Power Supply Chassis Power Centerplane Fan Backplane Carrier, System Controller/Centerplane Support Carrier, System Controller/Centerplane Support (July 2004) Carrier, Slots 1 2 3 6 7 8 10 11 12 15 16 17 Carrier, Slots 0 9 Carrier, Slots 4 5 13 14 Top Honeycomb Filter Front Honeycomb Filter Left Door Trim Panel Right Door Trim Panel DC Cover Top Rear Trim Panel Air Filter Cover Lower Trim Panel Top Front Trim Panel Air Filter (×6) Kick Plate Rear Plenum Panel Front Plenum Panel | Racks Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E25K |
| 370-4064 | 365-1399 [F] | Monitor |
| 370-4065 | 365-1400 | Monitor |
| 370-4066 | Left Side Door Lock and Key | Disk (external) |
| 370-4068 | High Speed Serial Interface (HSI/P) 2M 80-Pin 4-Port DB37 RS449 Breakout Cable (obsolete) 2M 80-Pin 4-Port DB37 RS449 Breakout Cable 2M 80-Pin 4-Port DB37 RS449 Breakout Cable 2M 80-Pin 4-Port DB37 RS449 Breakout Cable Data Cable (not included and not sold) NEBS Level-3 80-Pin 4-Port DB37 RS449 Breakout Cable | Communication |
| 370-4069 | Serial Asychronous Interface (SAI/P) 8-Port I/O Panel and 78-Pin Cable Data Cable (not included and not sold) NEBS Level-3 8-Port I/O Panel and 78-Pin Cable, Option X1001A | Communication |
| 370-4072 | SunVideo Plus | Graphics Sun Blade 1000 Sun Blade 2000 Sun Fire V480 Sun Fire V880 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 370-4076 | Air Filter, Option 7163 | Systems Telco Netra ct 800 |
| 370-4080 | Air Filter, Option 7162 | Systems Telco Netra ct 400 |
| 370-4081 | LED Board and Cable FRU LED Board Backplane to LED Board Cable | Disk (external) |
| 370-4082 | Backplane Daughter Board Backplane Daughter Board Bracket | Disk (external) |
| 370-4083 | Blank DDS-4 Tape | Removable Media |
| 370-4085 | Internal SCSI Cable Ferrite | Removable Media |
| 370-4086 | Type-6 Mouse, 4800 Baud | Input Device |
| 370-4096 | 128MB Memory Board FRU 256MB Memory Board Assembly/FRU 256MB Memory Board FRU 256MB Memory Board 512MB Memory Board Assembly/FRU 512MB Memory Board FRU | Memory Sun Netra t1 Systems Telco Netra ct 400 Systems Telco Netra ct 800 |
| 370-4099 | Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet Rear Panel AC Line Filter AC Power Cable AC Ground Cable Ultra 60 System Board Mounting Tray Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973) | Sun Enterprise 220R Sun Enterprise 420R Sun StorEdge N8200 |
| 370-4101 | 1/2-Height Peripheral Filler Panel Kit Internal 1/2-Height Peripheral Filler Panel External 1/2-Height Peripheral Filler Panel | Sun Ultra 10 Sun Ultra 5 |
| 370-4114 | A31 Technical Compute Farm RJ45 Cable, CPI-IWF1PE RJ45 Cable, CPI-IWF2PE Cisco AS2511-RJ Access Server Cisco WS-C3524-XL-EN 24-Port Gigabit Ethernet Switch Cisco WS-C3508G-XL-EN 8-Port Gigabit Ethernet Switch Cisco WS-G5484 1000BASE-SX Multimode GBIC Serial Port Adapter Arcom NX-7T 10BASE-T AUI Transceiver Arcom PX88BK-10 Ethernet Cable | Cables Data Cables by Type Cables External Data Cables by Type |
| 370-4115 | A31 Technical Compute Farm RJ45 Cable, CPI-IWF1PE RJ45 Cable, CPI-IWF2PE Cisco AS2511-RJ Access Server Cisco WS-C3524-XL-EN 24-Port Gigabit Ethernet Switch Cisco WS-C3508G-XL-EN 8-Port Gigabit Ethernet Switch Cisco WS-G5484 1000BASE-SX Multimode GBIC Serial Port Adapter Arcom NX-7T 10BASE-T AUI Transceiver Arcom PX88BK-10 Ethernet Cable | |
| 370-4116 | 111179 | Sun Blade 100 |
| 370-4116-01 | OBP 4.0 Version 31 | Boot PROMs Sun-4u Architecture |
| 370-4116-02 | OBP 4.0 Version 34 | Boot PROMs Sun-4u Architecture |
| 370-4116-03 | OBP 4.0 Version 37 | Boot PROMs Sun-4u Architecture |
| 370-4116-04 | OBP 4.0 Version 41 (MAC address 00:03:BA support) | Boot PROMs Sun-4u Architecture |
| 370-4116-05 | OBP 4.0 Version 45 + POST 1.2.6 | Boot PROMs Sun-4u Architecture |
| 370-4116-07 | OBP 4.3 Version 2 + POST 1.2.6 | Boot PROMs Sun-4u Architecture |
| 370-4116-09 | OBP 4.5 Version 9 + POST 2.0.1 (-08 was not released) | Boot PROMs Sun-4u Architecture |
| 370-4119 | Diagnostic Cable Kit | T3 |
| 370-4126 | 1/2-Height Peripheral Filler Panel Kit Internal 1/2-Height Peripheral Filler Panel External 1/2-Height Peripheral Filler Panel | Sun Ultra 10 Sun Ultra 5 |
| 370-4134 | 375-0064 | |
| 370-4149 | 128MB (1 × 128MB SDRAM DIMM) | Memory Sun Blade 100 Sun Blade 150 |
| 370-4149-01 | Early Sun Blade 150 systems were manufactured with incorrectly labeled DIMMs. | Sun Blade 150 |
| 370-4150 | 256MB (1 × 256MB SDRAM DIMM) | Memory Sun Blade 100 Sun Blade 150 |
| 370-4150-01 | Early Sun Blade 150 systems were manufactured with incorrectly labeled DIMMs. | Sun Blade 150 |
| 370-4151 | 512MB (1 × 512MB SDRAM DIMM) | Memory Sun Blade 100 Sun Blade 150 |
| 370-4151-01 | Early Sun Blade 150 systems were manufactured with incorrectly labeled DIMMs. | Sun Blade 100 Sun Blade 150 |
| 370-4152 | 48X EIDE CD-ROM [standard configuration] | Removable Media Sun Blade 100 Sun Blade 150 |
| 370-4153 | 12X DVD-ROM / 40X CD-ROM | Sun Blade 100 |
| 370-4154 | Seagate ST315310A (15.3GB 7200 RPM Ultra ATA/100) | Disks by Part Number Sun Blade 100 T3 |
| 370-4155 | cPCI 256MB Mezzanine Memory | Memory Sun Netra t1 |
| 370-4161 | If other than SUN cables are used on IEEE 1394 Camera, the pins on the cable do not fully engage to allow the function of the camera. | Input Device Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 |
| 370-4166 | 18.1" FPD Power Supply (AC-DC Converter, 100-240Vac Input, 14Vdc Output) | Monitor |
| 370-4169 | A31 Technical Compute Farm RJ45 Cable, CPI-IWF1PE RJ45 Cable, CPI-IWF2PE Cisco AS2511-RJ Access Server Cisco WS-C3524-XL-EN 24-Port Gigabit Ethernet Switch Cisco WS-C3508G-XL-EN 8-Port Gigabit Ethernet Switch Cisco WS-G5484 1000BASE-SX Multimode GBIC Serial Port Adapter Arcom NX-7T 10BASE-T AUI Transceiver Arcom PX88BK-10 Ethernet Cable | |
| 370-4170 | A31 Technical Compute Farm RJ45 Cable, CPI-IWF1PE RJ45 Cable, CPI-IWF2PE Cisco AS2511-RJ Access Server Cisco WS-C3524-XL-EN 24-Port Gigabit Ethernet Switch Cisco WS-C3508G-XL-EN 8-Port Gigabit Ethernet Switch Cisco WS-G5484 1000BASE-SX Multimode GBIC Serial Port Adapter Arcom NX-7T 10BASE-T AUI Transceiver Arcom PX88BK-10 Ethernet Cable | Sun StorEdge 3900/6900 Sun StorEdge 6900 series |
| 370-4171 | Slave Controller | Sun StorEdge L20 / L40 / L60 |
| 370-4172 | Vertical Lift Assembly | Sun StorEdge L20 / L40 / L60 |
| 370-4173 | DLT Empty Magazine (See part # 380-0516 for LTO Empty Magazine) | Sun StorEdge L20 / L40 / L60 |
| 370-4174 | L20 Library Controller Assembly (370-4174-01) L20 Remote Mgmt Card (370-4175-02) L20 Picker/Translate Assembly (370-4177-01) | Sun StorEdge L20 / L40 / L60 |
| 370-4174-01 | When replacing certain FRUs in a Sun StorEdge L20/L40/L60 Tape Library, failure to update the firmware may result in the tape library becoming non-functional. This problem is triggered by a firmware mismatch between different components in the library. The affected FRUs which may contain conflicting versions of firmware are: 370-4177-xx Picker/Translator Assembly 370-4174-xx Library Controller 370-4175-xx RMC (Remote Management Control) Card All three of these components must contain the same version of firmware. When a new FRU is installed with a different version, the library may display a "Partial-availability error" or "Firmware update needed" and there will appear to be a hardware problem. The library may be non-functional. | Sun StorEdge L20 / L40 / L60 |
| 370-4175 | L20 Library Controller Assembly (370-4174-01) L20 Remote Mgmt Card (370-4175-02) L20 Picker/Translate Assembly (370-4177-01) | Sun StorEdge L20 / L40 / L60 |
| 370-4175-02 | When replacing certain FRUs in a Sun StorEdge L20/L40/L60 Tape Library, failure to update the firmware may result in the tape library becoming non-functional. This problem is triggered by a firmware mismatch between different components in the library. The affected FRUs which may contain conflicting versions of firmware are: 370-4177-xx Picker/Translator Assembly 370-4174-xx Library Controller 370-4175-xx RMC (Remote Management Control) Card All three of these components must contain the same version of firmware. When a new FRU is installed with a different version, the library may display a "Partial-availability error" or "Firmware update needed" and there will appear to be a hardware problem. The library may be non-functional. | Sun StorEdge L20 / L40 / L60 |
| 370-4176 | Display Assembly | Sun StorEdge L20 / L40 / L60 |
| 370-4177 | L20 Library Controller Assembly (370-4174-01) L20 Remote Mgmt Card (370-4175-02) L20 Picker/Translate Assembly (370-4177-01) | Sun StorEdge L20 / L40 / L60 |
| 370-4177-01 | When replacing certain FRUs in a Sun StorEdge L20/L40/L60 Tape Library, failure to update the firmware may result in the tape library becoming non-functional. This problem is triggered by a firmware mismatch between different components in the library. The affected FRUs which may contain conflicting versions of firmware are: 370-4177-xx Picker/Translator Assembly 370-4174-xx Library Controller 370-4175-xx RMC (Remote Management Control) Card All three of these components must contain the same version of firmware. When a new FRU is installed with a different version, the library may display a "Partial-availability error" or "Firmware update needed" and there will appear to be a hardware problem. The library may be non-functional. | Sun StorEdge L20 / L40 / L60 |
| 370-4178 | L20 / L40 / L60 Power Supply | Sun StorEdge L20 / L40 / L60 |
| 370-4183 | 380-0343 [F] and 380-0500 [F] for 600-6808 [F] 380-0500 [F] and 600-6808 [F] for 380-0343 [F] 380-0343 [F] and 600-6808 [F] for 380-0500 [F] | Sun Ray |
| 370-4185 | Right Drive Board Kit, 375-0108 + 375-0109 * | Sun StorEdge L11000 |
| 370-4186 | Left Drive Board Kit, 375-0106 + 375-0107 * | Sun StorEdge L11000 |
| 370-4188 | Sun Ray 1 Assembly/FRU without Stand (380-0299-06 or later) 100 MHz microSPARC IIep System Board Power Supply Note: 600-6166 includes stand 370-3918 | Sun Ray |
| 370-4188-01 | Sun Ray 1 (380-0299-06 or less) | Sun Ray |
| 370-4189 | A31 Technical Compute Farm RJ45 Cable, CPI-IWF1PE RJ45 Cable, CPI-IWF2PE Cisco AS2511-RJ Access Server Cisco WS-C3524-XL-EN 24-Port Gigabit Ethernet Switch Cisco WS-C3508G-XL-EN 8-Port Gigabit Ethernet Switch Cisco WS-G5484 1000BASE-SX Multimode GBIC Serial Port Adapter Arcom NX-7T 10BASE-T AUI Transceiver Arcom PX88BK-10 Ethernet Cable | |
| 370-4190 | A31 Technical Compute Farm RJ45 Cable, CPI-IWF1PE RJ45 Cable, CPI-IWF2PE Cisco AS2511-RJ Access Server Cisco WS-C3524-XL-EN 24-Port Gigabit Ethernet Switch Cisco WS-C3508G-XL-EN 8-Port Gigabit Ethernet Switch Cisco WS-G5484 1000BASE-SX Multimode GBIC Serial Port Adapter Arcom NX-7T 10BASE-T AUI Transceiver Arcom PX88BK-10 Ethernet Cable | |
| 370-4206 | Mitac 200 Watt Power Supply | Power Supplies Sun Blade 100 |
| 370-4207 | Fan Assembly | Sun Blade 100 Sun Blade 150 |
| 370-4208 | PCI Riser Board | |
| 370-4209 | Cable Service Kit Power Switch and LED Cable Internal Smart Card Reader Cable Floppy Power Cable Floppy Data Cable IDE (Disk and CD/DVD) Power Cable Primary IDE Cable Secondary IDE Cable | Sun Blade 100 Sun Blade 150 |
| 370-4210 | Cable Service Kit Power Switch and LED Cable Internal Smart Card Reader Cable Floppy Power Cable Floppy Data Cable IDE (Disk and CD/DVD) Power Cable Primary IDE Cable Secondary IDE Cable | Sun Blade 100 Sun Blade 150 |
| 370-4211 | Triple Density Floppy [standard configuration] | Sun Blade 100 Sun Blade 150 |
| 370-4212 | New speaker design implemented in Ultra 5 to resolve harmonic noise issue is not backward compatible. All Ultra 5 systems have been shipping with newly designed speakers since May 2000. The new speaker is not backward compatible with the old style speaker. | Sun Ultra 5 |
| 370-4213 | 2GB Memory Option for AXmp+ | |
| 370-4214 | 256MB Memory Module for System Controller | Memory Sun Fire 12K / 15K Sun Fire 15K |
| 370-4215 | 370-4214 | Memory |
| 370-4224 | F6800 20MB Fire Link I/O Assembly, Option X4141A cPCI Filler Panel 20MB Fire Link I/O Assembly w Optical Module cPCI Fire Link Optical Module (Paroli) (×2) 20MB Fire Link I/O Assembly/FRU 10MB DIMM (×2) Fire Link I/O Assembly/FRU | I/O Sun Fire 12K / 15K Switches |
| 370-4227 | Ultra 10 Cable Service Kit/FRU Serial B and Parallel Cable Assembly CD-ROM Cable (removed from 370-3267-03) CD-ROM Cable with Ferrite Filter 1 EIDE Disk Cable (replaced 370-3205) Floppy Cable Audio Cable | Sun Ultra 10 Sun Ultra 5 |
| 370-4228 | A31 Technical Compute Farm RJ45 Cable, CPI-IWF1PE RJ45 Cable, CPI-IWF2PE Cisco AS2511-RJ Access Server Cisco WS-C3524-XL-EN 24-Port Gigabit Ethernet Switch Cisco WS-C3508G-XL-EN 8-Port Gigabit Ethernet Switch Cisco WS-G5484 1000BASE-SX Multimode GBIC Serial Port Adapter Arcom NX-7T 10BASE-T AUI Transceiver Arcom PX88BK-10 Ethernet Cable | Cables Data Cables by Type Cables External Data Cables by Type |
| 370-4229 | A31 Technical Compute Farm RJ45 Cable, CPI-IWF1PE RJ45 Cable, CPI-IWF2PE Cisco AS2511-RJ Access Server Cisco WS-C3524-XL-EN 24-Port Gigabit Ethernet Switch Cisco WS-C3508G-XL-EN 8-Port Gigabit Ethernet Switch Cisco WS-G5484 1000BASE-SX Multimode GBIC Serial Port Adapter Arcom NX-7T 10BASE-T AUI Transceiver Arcom PX88BK-10 Ethernet Cable | |
| 370-4231 | A31 Technical Compute Farm RJ45 Cable, CPI-IWF1PE RJ45 Cable, CPI-IWF2PE Cisco AS2511-RJ Access Server Cisco WS-C3524-XL-EN 24-Port Gigabit Ethernet Switch Cisco WS-C3508G-XL-EN 8-Port Gigabit Ethernet Switch Cisco WS-G5484 1000BASE-SX Multimode GBIC Serial Port Adapter Arcom NX-7T 10BASE-T AUI Transceiver Arcom PX88BK-10 Ethernet Cable | |
| 370-4232 | 380-0343 [F] and 380-0500 [F] for 600-6808 [F] 380-0500 [F] and 600-6808 [F] for 380-0343 [F] 380-0343 [F] and 600-6808 [F] for 380-0500 [F] | Sun Ray |
| 370-4233 | MicroPayflex smart cards with Sun artwork, pack of 25 | Sun Blade 1000 Sun Blade 2000 Sun Ray |
| 370-4234 | MicroPayflex smart cards, white, no artwork, pack of 25 | Sun Ray |
| 370-4237 | 256 MB SDRAM DIMM | Memory Sun Fire V100 Sun Fire V120 Sun Netra t1 |
| 370-4251 | Option 3682 1394 Camera Camera Base Kit Camera Base Camera Base 3.0M 1394 Cable Visual Collaboration Kit 1.0 | Input Device |
| 370-4252 | Option 3682 1394 Camera Camera Base Kit Camera Base Camera Base 3.0M 1394 Cable Visual Collaboration Kit 1.0 | Input Device |
| 370-4253 | Option 3682 1394 Camera Camera Base Kit Camera Base Camera Base 3.0M 1394 Cable Visual Collaboration Kit 1.0 | Input Device |
| 370-4262 | Empty DLT Tape Magazine | Sun StorEdge L7 Sun StorEdge L9 |
| 370-4272 | Fan Board | Graphics Sun Enterprise 450 Sun Fire 6800 |
| 370-4273 | Enterprise System Interface (ESI/P) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 370-4276 | StorEdge Network FC Switch-8 and StorEdge Network FC Switch-16 products installed in a Storage Area Network (SAN) configuration must have the proper level of firmware installed for proper operation. All switches in the SAN must contain matching firmware versions. Failure to verify and install the correct switch firmware when installing or replacing switches in a SAN can cause the switch to fail. It is important that the firmware of existing switches in a SAN and any replacement switch be checked for compatibility when installing a new switch into the SAN configuration. | Fibre Channel Sun StorEdge 3900/6900 Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4276-01 | Some StorEdge Network FC Switch-16 units were assembled and shipped from the vendor with their mounting brackets reversed. This could potentially result in these switches being installed backwards in the 72-inch StorEdge Expansion Cabinet. This improper installation may cause the inlet temperature of the switch to exceed its recommended range and this could affect the performance and the life of the switch. In addition, the connecting fibre cables might be damaged by hitting the rear cabinet door and may require replacement. | Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 370-4276-02 | User logins to a freshly installed SANSurfer GUI on November 25, 2001 or later may fail. The login for a pre-installed GUI might also fail after that date if no changes have been made to the user account. When customers are unable to login to the SANSurfer application, then the immediate impact is that they will not be able to use any SAN management utilities. Here is the failure message which displays on the console: "Login Failed" - Login Failure as user expires on 11/25/01. | Sun StorEdge 3900/6900 |
| 370-4278 | Internal CD-ROM Drive Kit CD-ROM Drive Assembly 24X CD-ROM Drive CD-ROM Cable/Board Assembly CD-ROM Paddle Board Assembly CD-ROM Data Cable Assembly | Removable Media Sun Fire V100 Sun Fire V120 Sun Netra t1 |
| 370-4281 | 512MB Registered/Buffered DIMM 1GB Registered/Buffered DIMM 30GB IDE Disk Drive 30GB IDE Disk Drive System Board 650MHz UltraSPARC IIi 650MHz UltraSPARC IIi Memory Riser Enclosure | Memory Sun Fire V100 Sun Fire V120 Sun Netra t1 |
| 370-4282 | PCMCIA Modem (in 370-5568, Slot 1) | Sun StorEdge 6320 System Sun StorEdge 6920 |
| 370-4283 | Chassis Assembly PCI Blank Panel PCI Mounting Bracket Top Cover Rear Cooling Fan Assembly | Sun Fire V120 Sun Netra 120 Sun Netra t1 |
| 370-4284 | Chassis Assembly PCI Blank Panel PCI Mounting Bracket Top Cover Rear Cooling Fan Assembly | Sun Netra t1 |
| 370-4285 | U2006 U2006 U13 U13 U13 U13 U2706 U2706 U2706 U3104 U3008 U48 U48 U2101 J3601 SCCR SCCR SCCR U25 SCCR U25 SCCR U25 SCCR U2101 U2101 U1804 U4618 U0205 U2501 U2106 ID Board | IDPROM Sun Fire V100 Sun Fire V120 Sun Netra 120 Sun Netra t1 |
| 370-4286 | Genie Lift with Straddle Base | |
| 370-4289 | 128MB REG/BUFF DIMM | Memory Sun Fire V100 |
| 370-4290 | LED/System Configuration Card Reader | Sun Fire V120 Sun Netra 120 Sun Netra t1 |
| 370-4293 | Speaker and Cable Assembly | Sun Blade 100 Sun Blade 150 |
| 370-4294 | SunPCi IIpro 128MB memory expansion | Memory |
| 370-4295 | SunPCi IIpro 256MB memory expansion | Memory |
| 370-4317 | Netra 20 DC Power Distribution Board PEX802 Board FRU Assembly | Power Supplies Sun Netra 20 |
| 370-4320 | 256MB Memory Option for AXe | |
| 370-4325 | POWER SUPPLY 200W ULTRA 5 (370-3162-02) POWER SUPPLY 250W ULTRA 10 (370-3171-02) POWER SUPPLY 200W A-PFC (370-4326-01) POWER SUPPLY 250W A-PFC (370-4325-01) | Power Supplies Sun Ultra 10 Sun Ultra 5 |
| 370-4325-01 | This FIN is to notify the field of a part change on the Sun Ultra 5 or Ultra10 Power Supply Unit. Effective Jan/01/2001, the PSU part number will change from 370-3162-xx/370-3171-xx to 370-4326-xx/370-4325-xx respectively. The new Ultra 5/U10 PSU (370-4326-xx/370-4325-xx) is backward compatible. However, the old PSU (P/N# 370-3162-xx/370-3171-xx) is not forward compatible. Both PSU's will be carried as FRU's. | Sun Ultra 10 Sun Ultra 5 |
| 370-4326 | POWER SUPPLY 200W ULTRA 5 (370-3162-02) POWER SUPPLY 250W ULTRA 10 (370-3171-02) POWER SUPPLY 200W A-PFC (370-4326-01) POWER SUPPLY 250W A-PFC (370-4325-01) | Power Supplies Sun Ultra 10 Sun Ultra 5 |
| 370-4326-01 | This FIN is to notify the field of a part change on the Sun Ultra 5 or Ultra10 Power Supply Unit. Effective Jan/01/2001, the PSU part number will change from 370-3162-xx/370-3171-xx to 370-4326-xx/370-4325-xx respectively. The new Ultra 5/U10 PSU (370-4326-xx/370-4325-xx) is backward compatible. However, the old PSU (P/N# 370-3162-xx/370-3171-xx) is not forward compatible. Both PSU's will be carried as FRU's. | Sun Ultra 10 Sun Ultra 5 |
| 370-4327 | Seagate ST320414A (20.1GB - 7200 RPM Ultra ATA/100) Barracuda ATA III | Disks by Part Number Sun Blade 100 Sun Ultra 10 Sun Ultra 5 |
| 370-4327-01 | Mirrored 20GB disk drives on Ultra 10 and Sun Blade 100 systems may be exposed to a drive compatibility issue when replacing a failed drive. | Sun Blade 100 Sun Ultra 10 |
| 370-4327-02 | 370-4327-03 | T3 |
| 370-4327-03 | 370-5560 | T3 |
| 370-4328 | Payflex smart cards with Sun artwork, pack of 25, | Sun Ray |
| 370-4333 | Payflex smart cards, white, no artwork, pack of 25, | Sun Ray |
| 370-4342 | Rack Stabilizer FRU Kit | Racks |
| 370-4344 | CD-ROM Cable and Paddleboard | Sun Fire E2900 Sun Fire V120 Sun Fire V1280 Sun Netra 120 Sun Netra 1280 Server Sun Netra t1 |
| 370-4347 | Plenum Air Filter (×6) (used in assembly 540-3985) | |
| 370-4348 | n/a | Sun Blade 100 Sun Ultra 10 Sun Ultra 5 |
| 370-4352 | CPU Fan | Sun Netra t1 |
| 370-4353 | 48X EIDE CD-ROM [standard] | Removable Media Sun Ultra 10 Sun Ultra 5 |
| 370-4356 | CPUSET-1P-1GB 1GB Memory 1× 300MHz Module 64MB 501-2480 64MB 370-4389 300MHz 501-4849 | |
| 370-4357 | 19-inch Slide Adapter Kit Assembly 10-32×1/2" screws (×8) M4×8mm screws (×20) M4×10mm screws (×4) M5×10mm screws (×6) Telescopic slide rail (×2) Chassis handle, 4U (×2) Chassis flange (×2) Front bracket [t 140 x ] (×2) Rear bracket [t 140 x ] (×2) Slide flange (×2) Mounting bracket (×2) Chassis handle, straight (×2) Fixings Kit | Racks Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 370-4360 | Fan Assembly, 127mm (CPU) | Sun Netra 20 |
| 370-4361 | 370-4353 [F] | Sun Ultra 10 Sun Ultra 5 |
| 370-4362 | PGX64 8/24-Bit Color Frame Buffer | Graphics Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 370-4363 | 80W AC Input Power Supply | Sun Fire V100 |
| 370-4364 | Processor Cabinet Left Logo Side Panel, Right Logo Side Panel, Power Supply Chassis, L Power Supply Chassis, L ** Power Centerplane, L Fan Backplane * Fan Backplane, L Frame Manager, L Frame Manager Extension, 250 mm, Carrier, System Controller/Centerplane Support, Carrier, Slots 1 2 3 6 7 8 10 11 12 15 16 17, Carrier, Slots 0 9, Carrier, Slots 4 5 13 14, Top Honeycomb Filter, Front Honeycomb Filter, Left Door Trim Panel, Right Door Trim Panel, DC Cover, Top Rear Trim Panel, Wireway Cover, Air Filter Cover, Lower Trim Panel, Top Front Trim Panel, Air Filter, Kick Plate, Rear Plenum Panel, Front Plenum Panel, | Racks |
| 370-4365 | Seagate ST320413A (20GB - 5400 RPM - IDE Disk) | Disks by Part Number |
| 370-4366 | Chassis | |
| 370-4370 | Memory | |
| 370-4379 | FC-AL Short Wave GBIC | Fibre Channel Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Switches |
| 370-4380 | Mediatray Assembly/FRU w/o Front Bezel 1 2 3 4 Motherboard (-02 = GEM200) (-04 = GEM359) 1 3 Motherboard (GEM200) 2 Disk Drive Adapter Board 1 3 Disk Drive Adapter Board 2 SCSI Loop LED Board 1 3 SCSI Loop LED Board 2 SCSI Loop Cable Power/Fault LED Cable 80-Pin, 9" Ribbon Cable 80-Pin, 4" Ribbon Cable Disk Drive Power LED Cable Chassis Assembly | Sun StorEdge D2 |
| 370-4384 | Mediatray Assembly/FRU w/o Front Bezel 1 2 3 4 Motherboard (-02 = GEM200) (-04 = GEM359) 1 3 Motherboard (GEM200) 2 Disk Drive Adapter Board 1 3 Disk Drive Adapter Board 2 SCSI Loop LED Board 1 3 SCSI Loop LED Board 2 SCSI Loop Cable Power/Fault LED Cable 80-Pin, 9" Ribbon Cable 80-Pin, 4" Ribbon Cable Disk Drive Power LED Cable Chassis Assembly | Sun StorEdge D2 |
| 370-4388 | Back Panel Status LED Assembly, L | Sun Fire V480 Sun Fire V490 |
| 370-4389 | CPUSET-2P-512MB 512MB Memory 2× 300MHz Modules 64MB 501-2480 64MB 370-4389 300MHz 501-4849 | |
| 370-4393 | Sun Fire Link Switch Option X4170A Sun Fire Link Switch Option 4170A AC Power Cord cPCI Filler Panel Tested Switch Assembly System Controller WCIX Module Switch Assembly 150W Power Supply Fan Tray Switch Chassis Assembly Chassis Backplane + AC Harness + AC Module | I/O Sun Fire 12K / 15K Sun Fire 6800 Switches |
| 370-4394 | Sun Fire V1280 DC Power Distribution Board | Power Supplies Sun Fire V1280 |
| 370-4395 | Brocade 2400 8-port FCAL switch | Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4395-01 | This FIN will explain the field procedure for the installation of Brocade 8 and 16 port switches into a Sun rack. There is no downtime and little customer impact as a result of this issue. | Sun StorEdge 9910/9960 Sun StorEdge A3500 Sun StorEdge A5200 T3 |
| 370-4396 | Brocade 16 port FCAL switch Brocade 16 port switch | Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4396-01 | This FIN will explain the field procedure for the installation of Brocade 8 and 16 port switches into a Sun rack. There is no downtime and little customer impact as a result of this issue. | Sun StorEdge 9910/9960 Sun StorEdge A3500 Sun StorEdge A5200 T3 |
| 370-4406 | Low Voltage Differential Terminator, VHDCI68 | Cables Data Cables by Type SCSI Sun StorEdge D2 |
| 370-4411 | Remote Management Card | Sun StorEdge L9 |
| 370-4412 | ATAPI/IDE Interface Toshiba SD-C2512 Slimline 1/2" Height FRU w/o Bkt or Cable | Removable Media Sun Fire V1280 Sun Fire V440 Sun Fire V480 Sun Fire V490 |
| 370-4419 | Western Digital WD400BB (40.0GB - 7200 RPM - IDE Disk) | Disk (internal) Disks by Part Number Sun Fire V100 T3 |
| 370-4419-01 | Supplier misformatted 40GB disk drive X-Options for Netra X1 systems as either 5GB or 7GB. | |
| 370-4422 | AC Input Connector Assembly | Sun Fire E2900 Sun Fire V1280 |
| 370-4427 | 4-Post Rack Kit (370-4427-02 = 27") - discontinued June 2002 (370-4427-03 = 25") - obsolete (370-4427-04 = 25") - add slide kit | Sun Fire V440 Sun Fire V480 Sun Fire V490 |
| 370-4427-02 | 370-4427 42 43 [F] | Sun Fire V440 Sun Fire V480 Sun Fire V490 |
| 370-4427-03 | 370-4427 42 43 [F] | Sun Fire V440 Sun Fire V480 Sun Fire V490 |
| 370-4427-04 | 370-4427 42 43 [F] | Sun Fire V440 Sun Fire V480 Sun Fire V490 |
| 370-4427-06 | 2009-03-11 | |
| 370-4430 | SunPCi IIpro 512MB memory expansion | Memory |
| 370-4435 | U2006 U2006 U13 U13 U13 U13 U2706 U2706 U2706 U3104 U3008 U48 U48 U2101 J3601 SCCR SCCR SCCR U25 SCCR U25 SCCR U25 SCCR U2101 U2101 U1804 U4618 U0205 U2501 U2106 ID Board | IDPROM Sun Netra 20 |
| 370-4439 | 16X DVD-ROM / 48X CD-ROM | Sun Blade 100 Sun Blade 150 |
| 370-4440 | Seagate ST340016A (40.8GB - 7200 RPM Ultra ATA/100) Barracuda ATA IV | Disk (internal) Disks by Part Number Sun Blade 150 T3 |
| 370-4504 | SW2400 Switch/FRU Professional Services Option | Switches |
| 370-4505 | SG-SNFCS44 Switch 380-0669 StorEdge 9900 Option | Switches |
| 370-4510 | Brocade SilkWorm 6400 64-Port Switch No FRU Available | Switches |
| 370-4511 | Short Wave GBIC, Option XT8-XBR-000025 Short Wave GBIC | Switches |
| 370-4512 | Long Wave GBIC, Option XT8-XBR-000011 Long Wave GBIC | Switches |
| 370-4517 | FCI-1063-N.P [S] | |
| 370-4518 | FC64-1063-N.P [S] | |
| 370-4519 | JNI 64Bit PCI Adapter Non OFC S/ W Interface | Fibre Channel |
| 370-4520 | 595-6072 370-5007 [F] | Switches |
| 370-4521 | 595-6073 370-5008 [F] | Switches |
| 370-4524 | 595-6076 | Switches |
| 370-4525 | 596-3154 | Switches |
| 370-4526 | 596-3155 | Switches |
| 370-4527 | 596-3156 | Switches |
| 370-4528 | 595-6080 | Switches |
| 370-4529 | 595-6081 | Switches |
| 370-4560 | 5502396-A | |
| 370-4569 | 5502383-A | |
| 370-4570 | SH185-B | |
| 370-4578 | XT8-JZ-050SS100PC | Cables Data Cables by Type |
| 370-4580 | T8-JZ-050SS025PC | |
| 370-4596 | IPO807-4 | |
| 370-4601 | 5502391-A [S] | |
| 370-4602 | 5502393-A | |
| 370-4603 | 5509138-B | |
| 370-4604 | 5509141-A | |
| 370-4606 | 5509143-A | |
| 370-4609 | 5509145-A | |
| 370-4610 | 5509143-C | |
| 370-4616 | 5509371-A | |
| 370-4617 | Empty 12-Drive Chassis/Midplane FRU | Sun StorEdge D2 |
| 370-4626 | JNI 64 bit PCI dual channel | Fibre Channel |
| 370-4627 | JNI 1 Gb Emerald, 64Bit SBus Non OFC | Fibre Channel |
| 370-4656 | XT8-JZ-050SL025PC | Cables Data Cables by Type |
| 370-4657 | XT8-JZ-GARY050LL025PC | Cables Data Cables by Type |
| 370-4666 | Smart Card Reader (single-sided) | Sun Blade 1000 Sun Blade 150 Sun Blade 2000 |
| 370-4666-01 | Solaris 8 patches required for Smart Card Reader operation on Sun Blade 100, 1000, and 2000 systems. | Sun Blade 100 Sun Blade 1000 Sun Blade 2000 |
| 370-4669 | 5509146-H | |
| 370-4682 | POWER SUPPLY,18.1",LCD MONITOR,A/D (can be substituted with 370-4166 [C] ) | Monitor |
| 370-4684 | Vicom Virtualization Engine 24-Port Ethernet Hub, 3-Com SuperStack 3C16441A RJ45M/F Roll-Over Adapter RJ45 to RJ45 Panel Mount Adapter DB-9F to RJ45F Adapter USB Panel Mount Extension Cable RJ45 to RJ45 Xover Cable, Xmt to Rcv, 10M 8-Port FC-AL Switch FRU Assembly 8-Port FC-AL Switch, Ancor/QLogic 16-Port FC-AL Switch FRU Assembly 16-Port FC-AL Switch, Ancor/QLogic Netra X1 Service Processor (600-7296) FRU StorEdge 3900/6900 72-inch Cabinet Front Door | Sun StorEdge 3900/6900 Sun StorEdge 6900 series |
| 370-4685 | Chassis | Sun Fire V100 |
| 370-4686 | FC/9000 24 Port Base System, Option T8-10-138 FC/9000 24 Port Base System (no FRU) | Switches |
| 370-4688 | 595-6228 370-5005 [F] | Switches |
| 370-4689 | 595-6229 | Switches |
| 370-4690 | 5502384-A | |
| 370-4691 | 5502385-A | |
| 370-4692 | 5502386-A | |
| 370-4693 | 5502387-A | |
| 370-4694 | 5502388-A | |
| 370-4695 | 5502389-A | |
| 370-4696 | 5502390-A | |
| 370-4697 | 5502394-A | |
| 370-4698 | 5502395-A | |
| 370-4699 | 5502402-A | |
| 370-4700 | 5502402-B | |
| 370-4701 | 5502402-C | |
| 370-4702 | 5502402-D | |
| 370-4703 | 5502402-E | |
| 370-4704 | 5502402-F | |
| 370-4705 | 5502402-G | |
| 370-4706 | 5502402-H | |
| 370-4707 | 5502402-J | |
| 370-4708 | 5502402-K | |
| 370-4709 | 5502402-L | |
| 370-4710 | 5502402-M | |
| 370-4711 | 5502402-N | |
| 370-4712 | 5502402-P | |
| 370-4713 | 5502402-Q | |
| 370-4714 | 5502402-R | |
| 370-4715 | 5502403-A | |
| 370-4716 | 5502403-B | |
| 370-4717 | 5502403-C | |
| 370-4718 | 5502403-D | |
| 370-4719 | 5502403-E | |
| 370-4720 | 5502403-F | |
| 370-4721 | 5502403-G | |
| 370-4722 | 5502403-H | |
| 370-4723 | 5502403-J | |
| 370-4724 | 5502403-K | |
| 370-4725 | 5502403-L | |
| 370-4726 | 5502403-M | |
| 370-4727 | 5502403-N | |
| 370-4728 | 5502403-P | |
| 370-4729 | 5502403-Q | |
| 370-4730 | 5502403-R | |
| 370-4731 | 5505147-A | |
| 370-4733 | 5509117-A | |
| 370-4734 | 5509118-A | |
| 370-4735 | 5509119-A | |
| 370-4736 | 5509120-A | |
| 370-4737 | 5509121-A | |
| 370-4738 | 5509121-B | |
| 370-4739 | 5509122-A | |
| 370-4741 | 5509140-B | |
| 370-4742 | 5509116-A | |
| 370-4743 | 5509125-A | |
| 370-4744 | BAT - CTR | |
| 370-4745 | 5509127-A | |
| 370-4746 | 5509128-A | |
| 370-4747 | 5509130-A | |
| 370-4748 | 5509131-A | |
| 370-4749 | Brocade Silkworm 12000 Switch with 64 Ports, option comes wth rack mount kit | Sun StorEdge 3510 Sun StorEdge 3511 FC Array Sun StorEdge 9990 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L8500 Tape Library T3 |
| 370-4750 | 5509133-A | |
| 370-4751 | 5509134-A | |
| 370-4752 | 5509135-A | |
| 370-4753 | 5509135-B | |
| 370-4754 | 5509136-A | |
| 370-4755 | 5509137-A | |
| 370-4756 | 5509137-B | |
| 370-4762 | 5509146-A | |
| 370-4763 | 5509146-B | |
| 370-4764 | 5509146-C | |
| 370-4765 | 5509146-D | |
| 370-4766 | 5509146-E | |
| 370-4767 | 5509146-F | |
| 370-4768 | 5509146-G | |
| 370-4770 | 5509146-J | |
| 370-4771 | 5509146-K | |
| 370-4772 | 5509146-L | |
| 370-4773 | 5509146-M | |
| 370-4774 | 5509146-N | |
| 370-4775 | 5509146-P | |
| 370-4776 | 5509146-Q | |
| 370-4777 | 5509146-R | |
| 370-4778 | 5509233-A | |
| 370-4779 | 5509233-B | |
| 370-4780 | 5509233-C | |
| 370-4781 | 5509233-D | |
| 370-4782 | 5509233-E | |
| 370-4783 | 5509233-F | |
| 370-4784 | 5509233-G | |
| 370-4785 | 5509233-H | |
| 370-4786 | 5509233-J | |
| 370-4787 | 5509233-K | |
| 370-4788 | 5509233-L | |
| 370-4789 | 5509233-M | |
| 370-4790 | 5509233-N | |
| 370-4791 | 5509233-P | |
| 370-4792 | 5509233-Q | |
| 370-4793 | 5509233-R | |
| 370-4794 | 5509129-A | |
| 370-4795 | 5509188-A | |
| 370-4796 | 5510657-A | |
| 370-4797 | 5510506-A | |
| 370-4798 | 5510507-A | |
| 370-4799 | 5510508-A | |
| 370-4800 | 5510510-A | |
| 370-4801 | 5510510-C | |
| 370-4802 | 5510510-D | |
| 370-4803 | 5510510-E | |
| 370-4804 | 5510510-F | |
| 370-4805 | 5510510-G | |
| 370-4806 | 5510510-H | |
| 370-4828 | FC/9000 128 Port Base System, Option T8-10-139 FC/9000 128 Port Base System FRU w 48 Ports | Switches |
| 370-4829 | High Availability Kit, Option T8-10-142 High Availability Kit FRU | Switches |
| 370-4830 | FC/9000 Server w/ Management SW, Option T8-10-143 FC/9000 Server w/ Management SW FRU | Switches |
| 370-4834 | 002-002212-110 | |
| 370-4843 | 3026.P | |
| 370-4856 | CPU/Memory Slot Clutched Pinion, | Sun Fire E2900 Sun Fire E2900, RoHS:YL Sun Fire V1280 Sun Netra 1280 Server Sun Netra 1280 Server, RoHS:YL Sun Netra 1290, RoHS:YL |
| 370-4857 | L2 Repeater Slot Clutched Pinion, | Sun Fire E2900 Sun Fire E2900, RoHS:YL Sun Fire V1280 Sun Netra 1280 Server Sun Netra 1280 Server, RoHS:YL Sun Netra 1290, RoHS:YL |
| 370-4858 | I/O System Controller Slot Clutched Pinion, | Sun Fire E2900 Sun Fire E2900, RoHS:YL Sun Fire V1280 Sun Netra 1280 Server Sun Netra 1280 Server, RoHS:YL Sun Netra 1290, RoHS:YL |
| 370-4861 | NiMH Battery Pack (install on 300-1562) | Sun StorEdge 6020/6120 Array Sun Storage[TM] Array Battery Life Cycle |
| 370-4863 | Brocade SilkWorm 2250 16-Port FC Switch (6 of these make up the Brocade 6400) | Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4865 | 5509141-B | |
| 370-4866 | 5510510-B | |
| 370-4867 | 5509143-B | |
| 370-4868 | 5509145-B | |
| 370-4869 | 5509123-C | |
| 370-4872 | Mitac X-250/PG -- 250 Watts | Power Supplies Sun Blade 150 |
| 370-4873 | PCI Riser Board | |
| 370-4874 | 512MB Registered/Buffered DIMM 1GB Registered/Buffered DIMM 30GB IDE Disk Drive 30GB IDE Disk Drive System Board 650MHz UltraSPARC IIi 650MHz UltraSPARC IIi Memory Riser Enclosure | Memory Sun Fire V120 Sun Netra t1 |
| 370-4897 | Vicom Virtualization Engine 24-Port Ethernet Hub, 3-Com SuperStack 3C16441A RJ45M/F Roll-Over Adapter RJ45 to RJ45 Panel Mount Adapter DB-9F to RJ45F Adapter USB Panel Mount Extension Cable RJ45 to RJ45 Xover Cable, Xmt to Rcv, 10M 8-Port FC-AL Switch FRU Assembly 8-Port FC-AL Switch, Ancor/QLogic 16-Port FC-AL Switch FRU Assembly 16-Port FC-AL Switch, Ancor/QLogic Netra X1 Service Processor (600-7296) FRU StorEdge 3900/6900 72-inch Cabinet Front Door | Sun StorEdge 3900/6900 Sun StorEdge 6900 series |
| 370-4898 | StorEdge Remote Response (595-6264 and 595-6279) RJ45 to RJ45 Cable, .38M Terminal Concentrator Modem (not included with 595-6279) International AC Power Adapter Kit RJ45 to DB25 Modem Adapter RJ45 to RJ45 Cable, 4M Category 5, Back-to-Back, RJ45 to RJ45, 1.0M RJ45 to RJ45 Rollover Cable Terminal Concentrator Rack Mount Kit | Ethernet |
| 370-4900 | StorEdge Remote Response (595-6264 and 595-6279) RJ45 to RJ45 Cable, .38M Terminal Concentrator Modem (not included with 595-6279) International AC Power Adapter Kit RJ45 to DB25 Modem Adapter RJ45 to RJ45 Cable, 4M Category 5, Back-to-Back, RJ45 to RJ45, 1.0M RJ45 to RJ45 Rollover Cable Terminal Concentrator Rack Mount Kit | Ethernet Sun StorEdge 6920 |
| 370-4902 | StorEdge Remote Response (595-6264 and 595-6279) RJ45 to RJ45 Cable, .38M Terminal Concentrator Modem (not included with 595-6279) International AC Power Adapter Kit RJ45 to DB25 Modem Adapter RJ45 to RJ45 Cable, 4M Category 5, Back-to-Back, RJ45 to RJ45, 1.0M RJ45 to RJ45 Rollover Cable Terminal Concentrator Rack Mount Kit | Cables Data Cables by Type Cables External Data Cables by Type Ethernet Sun StorEdge 3900/6900 Sun StorEdge 6900 series |
| 370-4903 | Vicom Virtualization Engine 24-Port Ethernet Hub, 3-Com SuperStack 3C16441A RJ45M/F Roll-Over Adapter RJ45 to RJ45 Panel Mount Adapter DB-9F to RJ45F Adapter USB Panel Mount Extension Cable RJ45 to RJ45 Xover Cable, Xmt to Rcv, 10M 8-Port FC-AL Switch FRU Assembly 8-Port FC-AL Switch, Ancor/QLogic 16-Port FC-AL Switch FRU Assembly 16-Port FC-AL Switch, Ancor/QLogic Netra X1 Service Processor (600-7296) FRU StorEdge 3900/6900 72-inch Cabinet Front Door | Cables Data Cables by Type Cables External Data Cables by Type Sun StorEdge 3900/6900 Sun StorEdge 6900 series |
| 370-4904 | Vicom Virtualization Engine 24-Port Ethernet Hub, 3-Com SuperStack 3C16441A RJ45M/F Roll-Over Adapter RJ45 to RJ45 Panel Mount Adapter DB-9F to RJ45F Adapter USB Panel Mount Extension Cable RJ45 to RJ45 Xover Cable, Xmt to Rcv, 10M 8-Port FC-AL Switch FRU Assembly 8-Port FC-AL Switch, Ancor/QLogic 16-Port FC-AL Switch FRU Assembly 16-Port FC-AL Switch, Ancor/QLogic Netra X1 Service Processor (600-7296) FRU StorEdge 3900/6900 72-inch Cabinet Front Door | Sun StorEdge 3900/6900 Sun StorEdge 6900 series |
| 370-4906 | 5502397-A [S] | |
| 370-4907 | 5513742-A | |
| 370-4908 | SSRR Power Adapter Kit | |
| 370-4910 | 24.1 AM-TFT-LCD MONITOR Power Supply Cable Kit 13W3/13W3 Video Cable DVI-D/DVI-D Video Cable 13W3/HD15 Video Cable S-Video Cable C-Video Cable USB Cable | Monitor |
| 370-4914 | JNI Host Bus Adapter (cPCI) | Fibre Channel |
| 370-4915 | JNI 2 Gb PCI Emerald 4, Host Bus Adapter (PCI) | Fibre Channel |
| 370-4916 | JNI 2 Gb SBus Emerald 4, Host Bus Adapter (SBus) | Fibre Channel |
| 370-4917 | VHDCI-68 LVD SCSI Terminator (Option XTA-3310-SC-TERM) | Cables Data Cables by Type Cables External Data Cables by Type Sun StorEdge 3310 |
| 370-4921 | XT8-JZ-050SL050PC | Cables Data Cables by Type |
| 370-4923 | XT8-JZ-050LL050PC | Cables Data Cables by Type |
| 370-4924 | XT8-JZ-050LL100PC | Cables Data Cables by Type |
| 370-4934 | Network Terminal Concentrator, comes with preconfigured software | Communication Sun StorEdge 3900/6900 Sun StorEdge 6900 series |
| 370-4939 | 1GB B200x Blade w/ 30GB Disk, Option X7521A 512MB DDR1 DIMM (×2) 30GB IDE Disk Drive System Board I/O Board Enclosure | Memory Sun Blade 1500 Sun Blade 2500 Sun Fire B1600 Blade System Chassis Sun Fire V210 Sun Fire V240 Sun Fire V440 |
| 370-4940 | 2GB B200x Blade w/ 30GB Disk, Option X7522A 1GB DDR1 DIMM (×2) 30GB IDE Disk Drive System Board I/O Board Enclosure | Memory Sun Blade 1500 Sun Blade 2500 Sun Fire B1600 Blade System Chassis Sun Fire V210 Sun Fire V240 Sun Fire V440 |
| 370-4944 | Ultra 10 Cable Service Kit/FRU Serial B and Parallel Cable Assembly CD-ROM Cable (removed from 370-3267-03) CD-ROM Cable with Ferrite Filter 1 EIDE Disk Cable (replaced 370-3205) Floppy Cable Audio Cable | Sun Ultra 10 |
| 370-4946 | Power Distribution System, Option X6849A [S] (after 9/11/03) 1 4 Power Distribution System, Option 6849A [S] (after 9/11/03) 1 2 3 4 Dual Input, 24 Output AC Power Sequencer Dual Input, 24 Output AC Power Strip AC Inlet Power Panel Upper Power Cords, Inlet 180-2056 (×2) + Outlet 180-2045 Lower Power Cords, Inlet 180-2057 (×2) + Outlet 180-2046 10A 90° IEC 320 Sheet E to IEC 320 C13 Power Cord, 1.0M, (×10) 10A 90° IEC 320 Sheet E to IEC 320 C13 Power Cord, 2.5M, (×10) Power Distribution System Installation Guide | Racks |
| 370-4948 | Power Distribution System, Option X6849A [S] 5 (before 9/11/03) Power Distribution System, Option 6849A [S] 5 (before 9/11/03) Dual Input, 24 Output AC Power Sequencer Dual Input, 24 Output AC Power Strip AC Inlet Power Panel Upper Power Cords, Inlet 180-2043 (×2) + Outlet 180-2045 4 Lower Power Cords, Inlet 180-2044 (×2) + Outlet 180-2046 4 10A 90° IEC 320 Sheet E to IEC 320 C13 Power Cord, 1M, (×10) 10A 90° IEC 320 Sheet E to IEC 320 C13 Power Cord, 2.5M, (×10) Power Distribution System Installation Guide | Racks |
| 370-4949 | Brocade 3800 2GB 16-Port Switch Short Wave SFP Long Wave SFP Short Wave SFP Long Wave SFP Loopback plug, 50/125 multimode Loopback plug, 9/125 multimode Power Supply Fan | Sun StorEdge 3510 Sun StorEdge 3511 FC Array Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 9990 Sun StorEdge L100 Tape Library Sun StorEdge L180 Sun StorEdge L25 Tape Library Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L8500 Tape Library Switches T3 |
| 370-4949-01 | This FIN will explain the field procedure for the installation of Brocade 8 and 16 port switches into a Sun rack. There is no downtime and little customer impact as a result of this issue. | Sun StorEdge 9910/9960 Sun StorEdge A3500 Sun StorEdge A5200 T3 |
| 370-4997 | CPU Fan | Sun Fire V440 |
| 370-4998 | PCI Fan | Sun Fire V440 |
| 370-4999 | FSW 10-101, InRange 1010566-001-00 | Switches |