Class: 501 | Series: 4
| Part Number | Description | Associated Systems |
|---|---|---|
| 501-4101 | 128MB | |
| 501-4117 | 64MB | |
| 501-4118 | 64MB | |
| 501-4119 | 64MB | |
| 501-4121 | 512MB | |
| 501-4123 | 128MB | |
| 501-4127 | Creator Series 1 (FFB) 24-Bit Frame Buffer | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-4128 | PCI I/O Riser Board (3.3V) | I/O Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4134 | 501-4358 | |
| 501-4143 | 0MB FRU (SCHIZO <=2.1) | Boot PROMs Sun-4u Architecture |
| 501-4143-15 | If the Emulex FC HBA card is placed on the same PCI Bus with any other PCI card which causes the Schizo chip to attempt a 64-bit PIO, a system panic would most likely result. The problem will not occur if the Emulex HBA card is installed alone on a PCI Bus. UltraSparc-III platforms utilizing the Schizo 2.1 or 2.2 ASIC may experience panics due to address parity errors on the PCI Bus. The problem has been seen on the Sun Fire 280R with the Emulex FC HBA card in combination with a PGX32 card installed on the same PCI Bus. This condition occurs when a card on the PCI Bus detects a 64-bit parity address error on the PCI Bus while another card on the same PCI Bus is performing a 64-bit PIO. The following error messages are displayed prior to a system panic: WARNING: pcisch-0: PCI fault log start: PCI SERR PCI error occurred on device #6 dwordmask=0 bytemask=0 PCI primary error (0): pcisch-0: PCI secondary error (0): pcisch-0: PBM AFAR 0.00000000: pcisch-0: PCI config space error status (4280): signaled system error. pcisch-0: PCI fault log end. panic[cpu1]/thread=2a10000bd40: pcisch-0: PCI bus 2 error(s)! | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V880 Sun Netra 20 |
| 501-4144 | 64MB | |
| 501-4145 | 256MB | |
| 501-4148 | 4-Slot SCSI Disk Backplane | Sun Enterprise 450 Sun Ultra 45 |
| 501-4148-04 | Systems with the 4 or 8 disk backplane may have other disk drives go offline when another disk drive is hot-plugged. IBM drives do not appear to be affected by this problem. | Sun Enterprise 450 |
| 501-4155 | Audio Module | |
| 501-4158 | The revision level printed on the labels for the 7-slot Backplane and the 11-slot Backplane for the A5000, A5100, and A5200 array are different than the revision levels that are dynamically reported by the arrays. | Sun StorEdge A5200 |
| 501-4158-03 | StorEdge A5200 with 11 slot HDA (501-4158-03) may fail LBF test in Stortools, and experience various SCSI Errors that are captured in the syslog file (/var/adm/messages). Examples of errors that might be seen are: SCSI Parity CRC SCSI Transport SCSI Transport Reject errors | Sun StorEdge A5200 |
| 501-4158-04 | When replacing either disk, R10 or F10, in slot 10 of an StorEdge A5200 array, a large amount of OFFLINE/ONLINE conditions occur and all disks of the A5200 become inaccessible. When the disk is re-inserted the connectivity is back but time consuming maintenance procedures are necessary. | Sun StorEdge A5200 |
| 501-4168 | 4.2 GB Wide SCSI Disk Card with 4x 2.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 2.1GB 7200 RPM Disk Drive FRU 2.1GB Disk Drive, Seagate ST32550WC 2.1GB Disk Drive, IBM DFHS-32160 2.1GB 7200 RPM Disk Drive FRU 2.1GB Disk Drive, Seagate ST32171WC 2.1GB Disk Drive, Quantum VK22J05 | SCSI |
| 501-4169 | PCI I/O Riser Board (5V) | I/O Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4172 | Creator3D Series 2 (FFB2) | Sun Ultra 30 Sun Ultra 60 |
| 501-4173 | Creator3D Series 2 (FFB2) 24-Bit Frame Buffer | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-4174 | Creator Series 2 (FFB2) | Sun Ultra 30 Sun Ultra 60 |
| 501-4178 | 250MHz UltraSPARC II Module (1MB Cache Blackbird) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4188 | Sun-4 Architecture (Generic) | |
| 501-4189 | 8-Slot SCSI Disk Backplane Dual Single-Ended Ultra/Wide SCSI (PCI) | Sun Enterprise 450 Sun Ultra 45 |
| 501-4189-04 | Systems with the 4 or 8 disk backplane may have other disk drives go offline when another disk drive is hot-plugged. IBM drives do not appear to be affected by this problem. | Sun Enterprise 450 |
| 501-4196 | Ultra 2 Model 1300 UPA Bus Terminator Module recommended on uni-processor models. An unterminated UPA bus may exhibit noise problems in very high intensity UPA bus activity applications. Symptoms may include CPU ECache data parity errors, ECC errors, asynch data errors or hangs. | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-4216 | Sun-4 Architecture (Generic) | |
| 501-4230 | SunPC 133-MHz 5x86 | |
| 501-4231 | 501-4232 | Graphics |
| 501-4232 | 501-4231 | Graphics |
| 501-4244 | 128MB | |
| 501-4249 | 250MHz UltraSPARC II Module (4MB Cache Blackbird) SRAM 100-5528 | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4266 | SBus I/O Board with SOC+ | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4266-05 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-4266-08 | In some configurations, after a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging of the FC cable at the FC hub, the SOC+ HBA might intermittently take the FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) received on an idle port of a SOC+ HBA can disrupt I/O activity on the second port of that HBA. | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 501-4270 | Removable Media Tray Assembly 2 Tray Assembly Floppy Data Cable, 7 cm Floppy Power Cable Keyswitch Assembly with Key 250-1317 LED Cable LED PCB Removable Media Tray Bezel SCSI Power Cable SCSI Data Cable, 39 cm RMA Door Hinge Assembly | Sun Enterprise 450 Sun Ultra 45 |
| 501-4271 | Configured Array Controller, Medium Grey Filler Panel Fibre Channel Optical Module Battery Module Array Controller, Medium Grey (110MHz microSPARC II) | Fibre Channel Sun SPARCstorage Array |
| 501-4271-01 | 525-1437-04 | Firmware |
| 501-4271-02 | 525-1437-05 | Firmware |
| 501-4271-03 | 525-1437-07 | Firmware |
| 501-4272 | Configured Array Controller, Medium Grey Filler Panel Fibre Channel Optical Module Battery Module Array Controller, Medium Grey (110MHz microSPARC II) | Fibre Channel Sun SPARCstorage Array |
| 501-4278 | 250MHz UltraSPARC II Module | Sun Enterprise 450 Sun Ultra 30 |
| 501-4287 | SBus I/O Board | Sun Enterprise 3000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6000 Sun Enterprise 6500 Systems Enterprise 4000 Systems Enterprise 5000 |
| 501-4288 | Graphics I/O Board | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4291 | 501-4677 | |
| 501-4300 | Motherboard | |
| 501-4302 | Quad Ethernet (QEC/S) Quad FastEthernet 1.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4308 | System Controller System Controller | Sun Netra 150 / E150 Sun Netra 150 / Ultra Enterprise 150 |
| 501-4312 | CPU/Memory Board - 0MB FRU w/o Module, 83MHz Gigaplane (2MB cache per module) | |
| 501-4321 | 501-4322 | |
| 501-4322 | 501-4323 | |
| 501-4323 | 501-4324 | |
| 501-4324 | 501-4323 | |
| 501-4325 | PCI I/O Board | I/O Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4327 | 4-8GB 1/4" SLR FlexiPack 25-50GB 1/4" MLR FlexiPack, Light Grey Half-Height Peripheral Cover Half-Height Filler Panel 48 Watt Power Supply, Type A120 Half-Height 16-Bit SCSI I/O Board SLR Address Select Cable MLR Adapter Ship Kit HD50-HD68-Pin Adapter Board Address Cable | Removable Media |
| 501-4340 | 128MB | |
| 501-4341 | 512MB | |
| 501-4345 | E10000 Control Board | |
| 501-4345-04 | E10000 hang created by control board going into a continuous reset mode. | Sun Enterprise 10000 |
| 501-4345-05 | E10000 hang created by control board going into a continuous reset mode. | Sun Enterprise 10000 |
| 501-4346 | Centerplane Support Board | |
| 501-4347 | E10000 System Board | |
| 501-4347-09 | Early life failures on the E10000 system board could cause system to crash. | Sun Enterprise 10000 |
| 501-4348 | Centerplane | |
| 501-4349 | Installation of certain SBus cards in slot 1 of E10000 having older I/O Mezzanine Boards has been found to cause unpredictable behavior, including resets, offlines, and undetected data corruption. | I/O Sun Enterprise 10000 |
| 501-4351 | E10000 Memory Board | Memory Sun Enterprise 10000 |
| 501-4356 | DLT4000 FlexiPack, Light Grey DLT4000 FlexiPack, Medium Grey Full-Height Tape Drive Cover, Light Grey Full-Height Tape Drive Cover, Medium Grey 48 Watt Power Supply, Type A120 Full-Height 8-Bit SCSI I/O Board Address Select Cable | Removable Media |
| 501-4357 | DLT7000 FlexiPack, Light Grey DLT7000 FlexiPack, Medium Grey DLT8000 FlexiPack, Medium Grey Full-Height Tape Drive Cover, Light Grey Full-Height Tape Drive Cover, Medium Grey 48 Watt Power Supply, Type A120 Full-Height 16-Bit SCSI I/O Board Address Select Cable | Removable Media |
| 501-4358 | 501-5403 | |
| 501-4359 | SunFastEthernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-4362 | 0MB 501-4362 8 × 4MB Ecache w/o USIII | |
| 501-4363 | Configuring 336 MHz CPU modules into a Enterprise 10000 system. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4365 | Fan Tray Centerplane | Sun Enterprise 10000 |
| 501-4366 | Sun Quad FastEthernet Sun Quad FastEthernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-4366-04 | When one or more PCI QFE cards are plugged into 33MHz slot(s), the Ultra 30 does not come out of reset when powered up. | Sun Ultra 30 |
| 501-4372 | The revision level printed on the labels for the 7-slot Backplane and the 11-slot Backplane for the A5000, A5100, and A5200 array are different than the revision levels that are dynamically reported by the arrays. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-4373 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 501-4375 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-4379 | Ultra 10 will hang running SunVTS with either an AFB or FFB2 video card installed. | Sun Ultra 10 |
| 501-4380 | 512MB | |
| 501-4381 | 1GB | |
| 501-4404 | PCI I/O Assembly (8 slot) | I/O Sun Fire 4800 Sun Fire 6800 |
| 501-4405 | 6 Slot System Centerplane (Factory Installed) | Sun Fire 6800 |
| 501-4406 | 3 Slot System Centerplane (4800), Factory Installed | Sun Fire 4800 |
| 501-4440 | 12 Slot SCSI Disk Backplane | Sun StorEdge A1000 Sun StorEdge Array Controller D1000 |
| 501-4450 | 0MB Ultra 60 System Board | Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-4450-08 | Ultra 60 system may hang when attempting to update flashPROM via patch 106455-03. When attempting to update the flashPROM from OBP 3.11 version 25 (525-1701-08) to OBP 3.11 version 26 (525-1701-09) the system will hang during the ERASURE procedure. Once this happens, the flashPROM has the OBP half erased and is unable to boot. | Sun Ultra 60 |
| 501-4450-10 | Ultra 60 systems with the 501-4450-11 motherboard (or the 501-4450-10 with Deviation sticker WO_14997) and 1 GB of memory installed have a high probability of experiencing undetectable data corruption. This could lead to corrupted application results and unstable system operation. | Sun Ultra 60 |
| 501-4450-11 | System Board (501-4450-10/11) | Allgemein / Unbekannt Sun Ultra 60 |
| 501-4450-13 | Ultra 60 systems shipped out of Sun UK may experience crystal reliability issues which results in mutliple failure types. | Sun Ultra 60 |
| 501-4477 | 270MHz UltraSPARC IIi Module | Sun Ultra 5 |
| 501-4478 | SBus I/O Board | I/O Sun Enterprise 10000 |
| 501-4489 | 512MB (4 × 128MB SDRAM DIMMs) | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 501-4489-06 | Sun Blade 1000 workstations with 128MB DIMMs may have intermittant Single Bit Correctable Errors. | Sun Blade 1000 Sun Blade 2000 |
| 501-4560 | 8 Slot SCSI Disk Backplane | |
| 501-4586 | Drive Bay Assembly w/ Backplane Drive Bracket FC-AL Backplane Assembly FC-AL Backplane FC-AL Cable | |
| 501-4633 | 1GB | |
| 501-4634 | 512MB | |
| 501-4637 | SIMM | Memory |
| 501-4639 | SIMM | Memory |
| 501-4669 | Alarm Module Alarm Module | Communication Systems Telco Netra t 1100 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-4670 | Chassis Assembly with 2 Removable Media Bays Chassis PCI Filler Panel Disk Drive Bay Assembly (1.0" or 1.6" height) SCSI Cable and Backplane Assembly Top Cover Front Panel Assembly Fan Filter Ground Strap Drive Cover Power Switch LED PCB/Cable Assembly LED Module LED Cable 12V Fan Assembly | Systems Telco Netra t 1100 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-4676 | 501-2486 | |
| 501-4677 | 501-4291 | |
| 501-4681 | Failure to remove power cables from E250 system board may result in NVRAM corruption. The NVRAM of an E250 (location U2706) will lose data (hostid, ethernet address, ...) if the NVRAM chip is changed (swapped) while the system is OFF but still plugged into an outlet and the power cable connectors on the mother board have NOT been disconnected. | Sun Enterprise 250 |
| 501-4681-09 | -08 | Boot PROMs Sun-4u Architecture |
| 501-4682 | Disk Drive Backplane Assembly 6-Slot SCSI Disk Backplane | Sun Enterprise 250 |
| 501-4683 | DC Power Distribution Board | Power Supplies Sun Enterprise 250 |
| 501-4707 | 128MB | |
| 501-4708 | 256MB | |
| 501-4709 | 256MB | |
| 501-4732 | Flash SIMM | Memory |
| 501-4733 | Flash SIMM | Memory |
| 501-4743 | CPUSET-1P-1GB 1GB Memory 1× 300MHz Module 64MB 501-2480 64MB 370-4389 300MHz 501-4849 | Memory Sun Enterprise 420R Sun Enterprise 450 Sun Ultra 80 |
| 501-4747 | Rear Cover Assembly Lockbox M3 × 8 mm Screw #4-40 Jack Screw 6-Slot Ultra SCSI Backplane M3 × 14 mm Screw | Disk (external) |
| 501-4772 | (ECO released 12/97, not manufactured) | |
| 501-4776 | E10000 Memory Board | Memory Sun Enterprise 10000 |
| 501-4777 | PCI I/O Riser Board (3.3V) PCI I/O Riser Board (5V) | I/O Sun Enterprise 10000 |
| 501-4778 | PCI I/O FRU Assembly 500-5126 3.3V Riser Kit 565-1474 | I/O Sun Enterprise 10000 |
| 501-4781 | 360MHz UltraSPARC II Module 4MB Cache Sapphire-Black | Sun Enterprise 220R Sun Ultra 60 |
| 501-4786 | E10000 System Board | |
| 501-4786-01 | Early life failures on the E10000 system board could cause system to crash. | Sun Enterprise 10000 |
| 501-4788 | Creator3D Series 3 (FFB2+) | Graphics Sun Blade 1000 Sun Blade 2000 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 501-4788-05 | Systems with FFB2+ installed may experience right shift of horizontal lines that contain the cursor and/or border line curves toward the mouse pointer when the mouse pointer is placed close to the left border of a cmdtool window. This can be easily seen when you set the FFB resolution to 960x680x112s with cmdtool's foreground color set to black and background to white. | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 501-4789 | Creator Series 3 (FFB2+) | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 501-4789-05 | Systems with FFB2+ installed may experience right shift of horizontal lines that contain the cursor and/or border line curves toward the mouse pointer when the mouse pointer is placed close to the left border of a cmdtool window. This can be easily seen when you set the FFB resolution to 960x680x112s with cmdtool's foreground color set to black and background to white. | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 501-4790 | Creator3D Series 3 (FFB2+) 24-Bit Frame Buffer | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-4791 | 200MHz UltraSPARC Module | Sun Ultra 2 |
| 501-4791-02 | Ultra 2 200MHz UltraSPARC CPU modules fail with SRAM and writeback data parity errors. | Sun Ultra 2 |
| 501-4799 | 5-Slot Centerplane | |
| 501-4799-02 | Manufacturing has determined that the Centerplane of the E3500 has a reliability problem that could result in a system shutdown. A VCC via and a ground pad are located in close proximity, and a capacitor (C0884) overlaps the via, creating a potential for a short between VCC and ground. | Sun Enterprise 3500 |
| 501-4818 | Remote System Control Board and Cable Remote System Control Cable | Sun Enterprise 250 |
| 501-4820 | FC-AL Interface Board Kit | Fibre Channel Sun Enterprise 3500 |
| 501-4823 | Disk Drive Enclosure FRU without Disk Drive Disk Drive Enclosure without Disk Drive Lockbox Disk Drive Cover Assembly M3 × 6 mm Screw Disk Drive Power Supply Assembly M3 × 25 mm Screw (obsolete) M3 × 25 mm Pan-Head Screw Fan Disk Drive DC Power Cable Disk Drive Ultra SCSI Interface Card M4 × 10 mm Screw M4 Nut 30 Watt Power Supply LED Cable #4-40M/2-56F Jackscrew Base Assembly | Disk (external) |
| 501-4826 | (ECO released 12/97, not manufactured) | |
| 501-4830 | PCI I/O Board | I/O Sun Enterprise 10000 |
| 501-4833-01 | In some configurations, after a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging of the FC cable at the FC hub, the SOC+ HBA might intermittently take the FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) received on an idle port of a SOC+ HBA can disrupt I/O activity on the second port of that HBA. | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 501-4836 | 250MHz UltraSPARC II Module (4MB Cache Blackbird) SRAM 100-5528 | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4837 | Quad Ethernet (QEC/S) Quad FastEthernet 1.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-4837-02 | The installation of the QFE Sbus Card (X1049A) on an E10000 domain running Solaris 2.5.1 or 2.6HW2 will require 'special instructions' to successfully complete the installation. These instructions are unnecessary if the Enterprise 10000 is running Solaris 2.6 HW3/98 or later. | Sun Enterprise 10000 |
| 501-4839 | E10000 Control Board | |
| 501-4844 | 501-4845 | |
| 501-4845 | 501-4348 | |
| 501-4849 | CPUSET-2P-512MB 512MB Memory 2× 300MHz Modules 64MB 501-2480 64MB 370-4389 300MHz 501-4849 | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 45 Sun Ultra 60 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-4857 | 250MHz UltraSPARC II Module | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 30 |
| 501-4860 | Elite3D-m6/FRU 501-5201 + 501-5058 | Graphics Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 501-4868 | cPCI I/O Assembly (4 slot) | I/O Sun Fire 4800 Sun Fire 6800 |
| 501-4881 | 501-4926 | I/O |
| 501-4882 | CPU/Memory Board - 0MB FRU w/o Module, 83MHz Gigaplane (2MB cache per module) | |
| 501-4883 | SBus I/O Board with SOC+ | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4883-02 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-4884 | Graphics I/O Board with SOC+ | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4884-02 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-4884-07 | In some configurations, after a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging of the FC cable at the FC hub, the SOC+ HBA might intermittently take the FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) received on an idle port of a SOC+ HBA can disrupt I/O activity on the second port of that HBA. | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 501-4901 | Remote System Control (RSC) Card | Sun Fire 280R |
| 501-4903 | E10000 System Board | |
| 501-4903-01 | Clarification of patches (patch matrix) needed to operate E10000 system boards. | Sun Enterprise 10000 |
| 501-4926 | PCI I/O Board | I/O Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4936 | Sun Fire E20K Assy, E20K-BASE-2 Rev 50 (see 602-3043) Sun Fire E25K Assy, E25K-BASE-2 Rev 50 (see 602-3044) Sun Fire E20K Assy, E20K-BASE-2 Rev 51 (see 602-3291) * Sun Fire E25K Assy, E25K-BASE-2 Rev 51 (see 602-3292) * System Expander Assembly System Expander Board FRU ** System Expander Board FRU System Expander DIMM Front Door Rear Door Power Cabinet Assembly Dual AC Input 48 Volt Output Power Supply Logic Centerplane Logic Centerplane Fan Tray Frame Manager Frame Manager Extension, 250 mm, | Racks Sun Fire 12K / 15K |
| 501-4944 | 8-Slot Centerplane | |
| 501-4946 | Clock Board - 83/90/100MHz Gigaplane (1:2, 1:3, 1:4 clock ratios) | |
| 501-4953 | Level 2 Repeater Board | Sun Fire 4800 Sun Fire 6800 |
| 501-4970 | 3 Slot System Centerplane (4810), Factory Installed | Sun Fire 4800 |
| 501-4995 | 400MHz UltraSPARC II (4MB Cache Sapphire-Black) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 |
| 501-4999 | 600MHz UltraSPARC III Module | Sun Blade 1000 |
| 501-4999-02 | Service procedures for replacement of early-release UltraSPARC III modules with pre-fetch pipeline problems. | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R |
| 501-4999-07 | Service procedures for replacement of early-release UltraSPARC III modules with pre-fetch pipeline problems. | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R |