Class: 540 | Series: 5
| Part Number | Description | Associated Systems |
|---|---|---|
| 540-5007 | Rack Kit Assembly | Sun Fire E4900 |
| 540-5010 | System Status Panel | Sun Netra CT 810 |
| 540-5011 | System Status Panel | Sun Netra CT 410 |
| 540-5012 | 540-5470 | Graphics |
| 540-5014 | Internal Slimline 8X DVD-ROM | Removable Media Sun Fire V120 Sun Netra t1 |
| 540-5016 | ESM (Environment Services Module) with Canister - Low Voltage Differential SCSI Controller Assembly | Sun StorEdge D2 |
| 540-5022 | Front Door Assembly | Sun StorEdge D2 |
| 540-5023 | Fan Assembly, 80mm (PSU) | Sun Netra 20 |
| 540-5025 | 8-Slot cPCI Drawer Assembly/FRU 8-Slot cPCI Backplane | Sun Netra CT 810 |
| 540-5026 | 5-Slot cPCI Diskfull Drawer Assembly/FRU 1 3U Mounting Bar 5-Slot cPCI Backplane Extension Board for Front CPU Termination Board Drawer Assembly | Sun Netra CT 410 |
| 540-5028 | Option X9653B Rack Mount Kit Universal Rack Bracket (×2) Tray #10-32 × 1/2" Screw (×16) 10×14×.04375 Screw (×4) | Sun StorEdge A1000 |
| 540-5044 | 36.4GB 10000 RPM Disk Drive Assembly/FRU 1.6" Spud Mounting Bracket | Disk (external) Disk (internal) |
| 540-5046 | Left Front Door with logo | Sun Fire 12K / 15K Sun Fire 15K |
| 540-5048 | Air Filter Kit Power Supply Filter (×6) Large Air Filter for Filter Assembly 540-3527 (×2) Small Air Filter for Filter Assembly 540-3528 (×1) | Systems Telco Netra ft 1800 |
| 540-5051 | Sun Fire 15K/12K failure logs must be returned with defective FRUs to ensure correct problem diagnosis and FRU repair. When returning F15K and F12K FRUs which have functionally failed, the appropriate files must be captured and sent to this alias: F15K_F12K_RMA@sun.com | Sun Fire 12K / 15K |
| 540-5051-02 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-5051-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5051-04 | Sun Fire 3800/4800/4810/6800 with 5.13.3 firmware gives warning message when USIII+ processors are installed on System Boards with Late_Write Ecache DIMMs. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5052 | Sun Fire 15K/12K failure logs must be returned with defective FRUs to ensure correct problem diagnosis and FRU repair. When returning F15K and F12K FRUs which have functionally failed, the appropriate files must be captured and sent to this alias: F15K_F12K_RMA@sun.com | Sun Fire 12K / 15K |
| 540-5052-02 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-5052-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5063 | System Control Switch/Power Button Cable | Sun Fire V480 Sun Fire V490 |
| 540-5064 | CPU Fan Tray (0) Left/Right Front Dress Panel, 18 × 218 mm Front Fan Tray Cable w/ Bracket 340-7241 | Sun Fire V480 Sun Fire V490 |
| 540-5077 | Left Rear Door with EMI | Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E25K |
| 540-5078 | 512MB B100s Blade w/ 30GB Disk, Option 7501 1GB B100s Blade w/ 30GB Disk, Option 7502 2GB B100s Blade w/ 30GB Disk, Option 7503 | Sun Fire B1600 Blade System Chassis |
| 540-5079 | 512MB B100s Blade w/ 30GB Disk, Option 7501 1GB B100s Blade w/ 30GB Disk, Option 7502 2GB B100s Blade w/ 30GB Disk, Option 7503 | Sun Fire B1600 Blade System Chassis |
| 540-5082 | 16-Slot Chassis Assembly/FRU | Sun Fire B1600 Blade System Chassis |
| 540-5084 | 256MB SDRAM DIMM | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-5085 | 512MB SDRAM DIMM, L | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-5086 | 4 GB (4 × 1GB SDRAM DIMMs) * | Memory Sun Fire 12K / 15K Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Netra 20 |
| 540-5088 | Enclosure Assembly Fan Tray with 3× 120 mm Fans Fan Tray, Option 9820 (replaced 540-4434 10/01) Power Supply Filler Panel Security Switch Lock DC Power Signal Cable DC Power Cable Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable FC-AL and RMA Power Cable (-04 required) FC-AL Cable 8-Bit SCSI Cable I 2 C Cable Control Cable | Sun Enterprise 220R Sun Enterprise 420R Sun Fire 280R |
| 540-5088-02 | Some Sun Fire 280R A35-AA ATO systems do not need fan tray upgrades when migrating to 900MHz or 1050MHz processors. | Sun Fire 280R |
| 540-5089-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5092 | Left Bracket Assembly, | Sun Fire V890 |
| 540-5093 | Right Bracket Assembly, | Sun Fire V890 |
| 540-5094 | Sun Fire CPU/Memory Uniboard with 2 UltraSPARC III Cu 900MHZ, 8MB Ecache each, & 4GB Memory | |
| 540-5094-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5095 | Sun Fire CPU/Memory Uniboard with 2 UltraSPARC III Cu 900MHZ, 8MB Ecache each, & 8GB Memory | |
| 540-5095-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5145 | N09-F Front Access DC Chassis Assembly Din-8 to DB-25 Serial Cable Chassis Assembly/FRU Rear DC Connector Cover Front Access DC Input Cable Chassis Assembly DC Input Filter Assembly | Systems Telco Netra ct 1600 (N09) |
| 540-5146 | N09-AR Rear Access AC Chassis Assembly AC Chassis Assembly Front Power Input Filler Panel AC Chassis Assembly Chassis Assembly AC Assembly/FRU | Systems Telco Netra ct 1600 (N09) |
| 540-5148 | N09-AR Rear Access AC Chassis Assembly AC Chassis Assembly Front Power Input Filler Panel AC Chassis Assembly Chassis Assembly AC Assembly/FRU | Systems Telco Netra ct 1600 (N09) |
| 540-5149 | SCSI LED Assembly | Sun Fire E2900 Sun Fire V1280 Sun Netra 1280 Server |
| 540-5150 | Sun Fireplane Interconnect Power Cabinet Assembly (replaced 540-4812) | Sun Fire 12K / 15K Sun Fire 15K |
| 540-5151 | Processor Cabinet (replaced 540-3985-07 - 09/01) | Sun Fire 12K / 15K Sun Fire 15K |
| 540-5151-01 | n/a | Sun Fire 12K / 15K Sun Fire 15K |
| 540-5158 | 12- Drive Chassis Assembly with Power Supply Empty Chassis Assembly 12-Slot SCSI Disk Backplane | Sun StorEdge D2 |
| 540-5160 | Empty 1.0" Disk Drive Slot Filler 9.1GB 10000 RPM Disk Drive FRU, NEBS Level 3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 | Sun StorEdge A1000 Sun StorEdge Array Controller D1000 T3 |
| 540-5178 | 36.4GB - 15000 RPM FC-AL, Disk Assembly with 1 bracket, and 1 of the following plates, and 1 of the following disks: | Disks by Part Number Sun StorEdge A5200 T3 |
| 540-5178-01 | Seagate ST336752FC (36.4GB) disk drives should not be installed into non-RAID configurations. Seagate ST336752FC (36GB) disk drives should only be installed into configurations which use Veritas Volume Manager or SDS RAID software, or hardware RAID configurations. | Sun StorEdge 3900/6900 Sun StorEdge A5200 T3 |
| 540-5179 | 36.4GB - 15000 RPM FC-AL, Disk Assembly with one bracket and one of the following disks: | Disk (internal) Disks by Part Number Sun StorEdge 3900/6900 Sun StorEdge 6900 series T3 |
| 540-5179-01 | Seagate ST336752FC (36.4GB) disk drives should not be installed into non-RAID configurations. Seagate ST336752FC (36GB) disk drives should only be installed into configurations which use Veritas Volume Manager or SDS RAID software, or hardware RAID configurations. | Sun StorEdge 3900/6900 Sun StorEdge A5200 T3 |
| 540-5183 | N09-AR Rear Access AC Chassis Assembly AC Chassis Assembly Front Power Input Filler Panel AC Chassis Assembly Chassis Assembly AC Assembly/FRU | Systems Telco Netra ct 1600 (N09) |
| 540-5185 | Switch and System Controller (SSC) Assembly/FRU | Sun Fire B1600 Blade System Chassis Switches |
| 540-5186 | Enclosure | Sun Fire B1600 Blade System Chassis |
| 540-5187 | Lower Plastic w Board and Cable | Sun Fire V1280 Sun Netra 1280 Server |
| 540-5191 | Left Door | Sun Fire V1280 Sun Netra 1280 Server |
| 540-5192 | Right Door | Sun Fire V1280 Sun Netra 1280 Server |
| 540-5193 | Single Fan Assembly/FRU (×8) (gold/tin or tin/tin connectors) | Sun Fire E2900 Sun Fire V1280 Sun Netra 1280 Server |
| 540-5198 | Chassis Assembly PCI Blank Panel PCI Mounting Bracket Rear Dual Fan Assembly Top Cover | Sun Fire V120 Sun Netra 120 |
| 540-5199 | Vicom Virtualization Engine 24-Port Ethernet Hub, 3-Com SuperStack 3C16441A RJ45M/F Roll-Over Adapter RJ45 to RJ45 Panel Mount Adapter DB-9F to RJ45F Adapter USB Panel Mount Extension Cable RJ45 to RJ45 Xover Cable, Xmt to Rcv, 10M 8-Port FC-AL Switch FRU Assembly 8-Port FC-AL Switch, Ancor/QLogic 16-Port FC-AL Switch FRU Assembly 16-Port FC-AL Switch, Ancor/QLogic Netra X1 Service Processor (600-7296) FRU StorEdge 3900/6900 72-inch Cabinet Front Door | Sun StorEdge 3900/6900 Sun StorEdge 6900 series |
| 540-5204 | 181.5GB - 7200 RPM FC-AL, Disk Assembly with one bracket and one of the following disks: | Disk (internal) Disks by Part Number Sun StorEdge 3900/6900 Sun StorEdge 6900 series T3 |
| 540-5205 | Sun Fire Link Switch Option X4170A Sun Fire Link Switch Option 4170A AC Power Cord cPCI Filler Panel Tested Switch Assembly System Controller WCIX Module Switch Assembly 150W Power Supply Fan Tray Switch Chassis Assembly Chassis Backplane + AC Harness + AC Module | I/O Sun Fire 12K / 15K Sun Fire 6800 Switches |
| 540-5207 | Sun OC48 Pack0et Over Sonet SRP Cable Kit Cable, External Copper, SRP Data, 50cm Cable, Internal Coaxial, SRP Clock | Sun Fire V880 |
| 540-5208 | 72-inch Cabinet Assembly IEC 320 C13 to IEC 320 C14 Power Cord, 2.5M Power Sequencer (×2) Rear Door Assembly 2x1U Power Sequence Cover 2x1U Power Sequence Rear Mounting Bracket Ethernet Cable, Category 5, RJ45 to RJ45, 1M LC-LC Fibre Optical Cable, 2M Master MPT to Fanout Cable MTP-MTP Fanout Cable 2U FC-AL Switch Vent Panel Curved Front Door, Option EXP-FRTDR-070 Patch Panel Assembly Panel Mount MPO/MPO FC Coupler Panel Mount LC Adapter 72-inch Cabinet | Racks Sun StorEdge 3900/6900 Sun StorEdge 6130 Array Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge 6920 |
| 540-5221 | Curved Front Bezel Assembly, Iridescent Purple | Sun Blade 2000 |
| 540-5222 | I/O Fan (gold/tin or tin/tin connectors) | I/O Sun Fire V1280 |
| 540-5229 | Top Cover | Sun Fire V440 |
| 540-5237 | Left Cover Assembly, Charcoal Grey Left Cover Assembly, Iridescent Purple (Limited Edition) | Sun Blade 2000 |
| 540-5238 | SB2000 Torque Tool Assembly Fixed 5 In/Lb Torque Wrench, #2 Square Bit | Sun Blade 2000 |
| 540-5245 | CPU/Memory UniBoard w/ 4× US III Cu 2.3 900MHz, 8GB | |
| 540-5258 | PCI Fan Tray Assembly | Sun Fire V440 |
| 540-5267 | Capacity On Demand (COD) Uniboard bundle with 4 unlicensed UltraSPARC III CU 1050MHz, 8MB Ecache, & 8GB Memory. Note: COD Right-To-Use (RTU) licenses must be ordered separately to activate. | |
| 540-5267-01 | Sun Fire 3800/4800/4810/6800 with 5.13.3 firmware gives warning message when USIII+ processors are installed on System Boards with Late_Write Ecache DIMMs. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5267-02 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5268 | Sun Fire CPU/Memory Uniboard with 4 UltraSPARC III Cu 1050MHZ, 8MB Ecache each, & 16GB Memory | |
| 540-5268-02 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5269 | Sun Fire CPU/Memory Uniboard with 4 UltraSPARC III Cu 1050MHZ, 8MB Ecache each, & 32GB Memory | |
| 540-5269-02 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5271 | Sun Fire CPU/Memory Uniboard with 2 UltraSPARC III Cu 1050MHz, 8MB Ecache each, & 2GB Memory | |
| 540-5272 | Sun Fire CPU/Memory Uniboard with 2 UltraSPARC III Cu 1050MHz, 8MB Ecache each, & 4GB Memory | |
| 540-5273 | Sun Fire CPU/Memory Uniboard with 2 UltraSPARC III Cu 1050MHz, 8MB Ecache each, & 8GB Memory | |
| 540-5274 | Sun Fire CPU/Memory Uniboard with 4UltraSPARC III Cu 1050MHz, 8MB Ecache each, & 4GB Memory | |
| 540-5275 | Sun Fire CPU/Memory Uniboard with 4 UltraSPARC III Cu 1050MHZ, 8MB Ecache each, & 8GB Memory | |
| 540-5278 | Disk Drive Slot Filler | Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6920 |
| 540-5285 | CPU/Memory Board Cage Assembly | Sun Netra 440 Server |
| 540-5287 | DVD Bezel Assembly | Sun Fire V480 |
| 540-5288 | Chassis Assembly Chassis Assembly Chassis Housing Assembly Chassis Front Chassis Rear I/O Panel Peripheral Bay Shelf Receiving Chassis Shroud CPU Shroud Shroud Cover CPU Shroud Cover Processor Module Slot Filler Panel | Sun Blade 2000 |
| 540-5289 | Left Cover Assembly, Charcoal Grey Left Cover Assembly, Iridescent Purple (Limited Edition) | Sun Blade 2000 |
| 540-5290 | PCI I/O Board and System Controller (IB_SSC) | Sun Fire V1280 |
| 540-5292 | Chassis Assembly Chassis Assembly Chassis Housing Assembly Chassis Front Chassis Rear I/O Panel Peripheral Bay Shelf Receiving Chassis Shroud CPU Shroud Shroud Cover CPU Shroud Cover Processor Module Slot Filler Panel | Sun Blade 2000 |
| 540-5299 | CPU Fan with Air Duct | Sun Fire V120 Sun Netra 120 |
| 540-5300 | 4RU Chassis Subassembly, L | Sun Fire V440 |
| 540-5301 | Chassis Assembly w/o Power Supply | Sun Fire V440 |
| 540-5304 | Sun Fire E20K Assy, E20K-BASE-2 Rev 50 (see 602-3043) Sun Fire E25K Assy, E25K-BASE-2 Rev 50 (see 602-3044) Sun Fire E20K Assy, E20K-BASE-2 Rev 51 (see 602-3291) * Sun Fire E25K Assy, E25K-BASE-2 Rev 51 (see 602-3292) * System Expander Assembly System Expander Board FRU ** System Expander Board FRU System Expander DIMM Front Door Rear Door Power Cabinet Assembly Dual AC Input 48 Volt Output Power Supply Logic Centerplane Logic Centerplane Fan Tray Frame Manager Frame Manager Extension, 250 mm, | Racks Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E25K |
| 540-5305 | Disk Drive Door Assembly | Sun Fire V440 |
| 540-5306 | Power Supply Door Assembly | Sun Fire V440 |
| 540-5309-01 | Sunon fans used in the SunCobalt RaQ3 and RaQ4 products have proven to have a high failure rate due to fans spinning intermittently, or not at all. | |
| 540-5318 | Array Chassis and Midplane | |
| 540-5322 | 36.4GB - 15000 RPM FC-AL, Disk assembly with 1 SPUD bracket and 1 of the following disks: | Disk (internal) Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6920 T3 |
| 540-5328 | Rear I/O EMI Assembly | Sun Fire V440 |
| 540-5330 | 73.4GB - 10000 RPM FC-AL, Disk assembly with 1 SPUD bracket and 1 of the following disks: | Disk (internal) Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6920 T3 |
| 540-5349 | Filler Panel Kit, Option X6826A 1RU Filler Panel 2RU Filler Panel 4RU Filler Panel | Racks |
| 540-5350 | Filler Panel Kit, Option X6826A 1RU Filler Panel 2RU Filler Panel 4RU Filler Panel | Racks |
| 540-5351 | Filler Panel Kit, Option X6826A 1RU Filler Panel 2RU Filler Panel 4RU Filler Panel | Racks |
| 540-5352 | Cabinet Assembly Key T-Wrench 1/4" × 50 mm #3 Phillips Bit 13 mm / 19 mm Wrench 3 mm Allen Wrench 6 mm Allen Wrench 5 mm Allen Wrench Top Panel Assembly Backlight Assembly | Racks |
| 540-5372 | 512MB Registered/Buffered DIMM 1GB Registered/Buffered DIMM 30GB IDE Disk Drive 30GB IDE Disk Drive System Board 650MHz UltraSPARC IIi 650MHz UltraSPARC IIi Memory Riser Enclosure | |
| 540-5383 | CPU Fan Tray Assembly | Sun Fire V440 |
| 540-5384 | Array Interconnect Card (loop card) Assembly | Fibre Channel Sun StorEdge 6020/6120 Array |
| 540-5390 | 5-Slot cPCI Diskless Drawer Assembly/FRU 2 5-Slot cPCI Backplane Extension Board for Front CPU Termination Board Drawer Assembly | Sun Netra CT 410 |
| 540-5392 | Blank Blade | Sun Fire B1600 Blade System Chassis |
| 540-5393 | Tape Drive Filler Panel, Option X1093A | Sun Fire E2900 Sun Fire V1280 Sun Netra 1280 Server |
| 540-5396 | 0MB FRU with 2 400MHz Modules | |
| 540-5397 | 2GB FRU with 2 400MHz Modules | |
| 540-5400 | 0MB FRU with 1 400MHz Module | |
| 540-5402 | CPU/Memory UniBoard w/ 4× US III Cu 2.3 900MHz, 32GB | |
| 540-5404 | Network 2GB FC Switch-16 AC Y Power Cord (Option X319YA) 1U Mounting Rail (replaced by 565-1735) 2U Vented Panel Switch Assembly/FRU Slide Bracket 16-Port Switch Rack Mount Kit 2GB Switch Power Supply 2GB Switch Fan | Fibre Channel Sun StorEdge 3510 Sun StorEdge 3511 FC Array Sun StorEdge 3900/6900 Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Sun StorEdge L500 Sun StorEdge L8500 Tape Library Switches T3 |
| 540-5406 | 560-2744 [F] | Sun Fire E2900 Sun Fire V1280 Sun Netra 1280 Server |
| 540-5407 | 560-2743 [F] | Sun Fire E2900 Sun Fire V1280 Sun Netra 1280 Server |
| 540-5408 | 18.2GB 10000 RPM Disk Drive Assembly/FRU 36.4GB 10000 RPM Disk Drive Assembly/FRU 73.4GB 10000 RPM Disk Drive Assembly/FRU 73.4GB 10000 RPM Disk Drive Assembly/FRU | Disk (external) Disk (internal) Disks by Part Number Sun Blade 2000 Sun Fire 280R Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 T3 |
| 540-5409 | Upper Plastic, | Sun Fire V1280 Sun Netra 1280 Server |
| 540-5410 | 8-Fan Tray Subassembly | Sun Fire E2900 Sun Fire V1280 Sun Netra 1280 Server |
| 540-5411 | DVD-ROM Assembly | Removable Media Sun Fire V1280 |
| 540-5412 | Right Door Air Filter, | Sun Fire E2900 Sun Fire E2900, RoHS:YL Sun Fire V1280 Sun Netra 1280 Server Sun Netra 1280 Server, RoHS:YL Sun Netra 1290, RoHS:YL |
| 540-5413 | Left Door Air Filter, | Sun Fire E2900 Sun Fire E2900, RoHS:YL Sun Fire V1280 Sun Netra 1280 Server Sun Netra 1280 Server, RoHS:YL Sun Netra 1290, RoHS:YL |
| 540-5418 | Motherboard Assembly (August 2003) | |
| 540-5419 | 36GB - 10000 RPM, Disk Drive | SPARCstation LX |
| 540-5420 | 72GB - 10000 RPM, Disk Drive | SPARCstation LX |
| 540-5423 | ASSY,SINGLE 256MB DIMM | SPARCstation LX |
| 540-5425 | ASSY,SINGLE 512MB DIMM | SPARCstation LX |
| 540-5427 | ASSY,SINGLE 1GB DIMM | SPARCstation LX |
| 540-5429 | Power Supply, 250W | SPARCstation LX |
| 540-5430 | Fan Module (5 unitized fans) | SPARCstation LX |
| 540-5431 | Front Bezel | SPARCstation LX |
| 540-5432 | Floppy Drive/CD-ROM Combo Unit | SPARCstation LX |
| 540-5433 | Bracket Set | SPARCstation LX |
| 540-5436 | System Board, no CPU, no memory | SPARCstation LX |
| 540-5438 | 1.4GHz Processor | SPARCstation LX |
| 540-5438-01 | LX50 systems may fail DOA with solid Amber LED. | SPARCstation LX |
| 540-5439 | Cable Kit (cables inside server chassis) | SPARCstation LX |
| 540-5440 | Sun LX50 Server CRU with system board, without major CRUs (no CPUs, memory, disks, or floppy/CD-ROM combo unit) | SPARCstation LX |
| 540-5451 | Empty 1.0" Disk Drive Slot Filler 9.1GB 10000 RPM Disk Drive FRU, NEBS Level 3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 | Disk (internal) Disks by Part Number Sun StorEdge A1000 Sun StorEdge Array Controller D1000 T3 |
| 540-5454 | 512MB B100s Blade w/ 30GB Disk, Option 7501 1GB B100s Blade w/ 30GB Disk, Option 7502 2GB B100s Blade w/ 30GB Disk, Option 7503 | Sun Fire B1600 Blade System Chassis |
| 540-5455 | 36.4GB 10000 RPM NEBS Disk Drive Assembly/FRU 73.4GB 10000 RPM NEBS Disk Drive Assembly/FRU 3 73.4GB 10000 RPM NEBS Disk Drive Assembly/FRU 3 73.4GB 15000 RPM NEBS Disk Drive Assembly/FRU 4 | Disk (internal) Disks by Part Number Sun Fire E2900 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V250 Server Sun Netra CT 410 Sun Netra CT 810 Sun StorEdge A1000 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge S1 T3 |
| 540-5456 | 73GB 10000 RPM Disk Drive Option Assembly ( Option X5886A [S] ) 73GB 10000 RPM Disk Drive Assembly/FRU 73GB 10000 RPM Disk Drive Assembly (replaced 599-2652 in 3/03) Media Tray Sled 73GB 10000 RPM Disk Drive Assembly | Disk (internal) Disks by Part Number Sun Blade 2500 Sun Fire V440 Sun StorEdge D2 T3 |
| 540-5459 | 146GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: | Disk (internal) Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 T3 |
| 540-5462 | 36.4GB - 10000 RPM, Disk Assembly with 1 SPUD bracket, and 1 of the following disks: | Disk (internal) Disks by Part Number Sun Fire V440 T3 |
| 540-5464 | Disk Drive Slot Filler | Sun StorEdge 6920 |
| 540-5467 | 559-0070 540-5849 | |
| 540-5470 | XVR-4000 Graphics Accelerator | Graphics Sun Fire V880 |
| 540-5471 | 146GB - 10000 RPM FC-AL, Disk assembly with 1 SPUD bracket and 1 of the following disks: | Disk (internal) Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6920 T3 |
| 540-5474 | Capacity On Demand (COD) Uniboard bundle with 4 unlicensed UltraSPARC III Cu 900MHz, 8MB Ecache, & 8GB Memory. Note: COD Right-To-Use (RTU) licenses must be ordered separately to activate. | |
| 540-5475 | Capacity On Demand (COD) Uniboard bundle with 4 unlicensed UltraSPARC III Cu 1050MHz, 8MB Ecache, & 8GB Memory. Note: COD Right-To-Use (RTU) licenses must be ordered separately to activate. | |
| 540-5476 | XVR-1000 Graphics Accelerator (FFB3) | Graphics Sun Blade 1000 Sun Blade 2000 Sun Ultra 60 Sun Ultra 80 |
| 540-5477 | Fire Link Optical Module, Option X4175A 1 Fire Link Optical Module (Paroli) Assembly cPCI Fire Link Optical Module (Paroli) | I/O Sun Fire 12K / 15K Sun Fire 6800 Switches |
| 540-5478 | Front Door Kit, Option X6825A [S] Hinge Pin Latch Bracket Front Door Front/Rear Door (added November 2003) Front/Rear Door w/o EMI (added August 2004) Logo Holder Assembly Front Door Installation Manual | Racks |
| 540-5479 | Cabinet Assembly w/ Power Distribution, Cabinet Assembly w/o Power Distribution, Top Panel Assembly/FRU, Backlight Assembly Cabinet Frame Side Panel, 42U × 800 mm Extension Side Panel, 42U × 200 mm Shipping Bolt Down Bracket Leveler Foot Antitip Bar Heavy Duty Caster Front/Rear Door, | Racks |
| 540-5482 | RAID Controller Slot Filler | Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6920 |
| 540-5489 | Level 2 Repeater Assembly | |
| 540-5521 | Level 2 Repeater Assembly | |
| 540-5522 | 36.4GB - 10000 RPM, Disk Assembly with 1 of the following disks: | Disk (internal) Disks by Part Number Sun StorEdge 3310 T3 |
| 540-5526 | 1GB B200x Blade w/ 30GB Disk, Option X7521A 512MB DDR1 DIMM (×2) 30GB IDE Disk Drive System Board I/O Board Enclosure | Sun Fire B1600 Blade System Chassis |
| 540-5527 | 2GB B200x Blade w/ 30GB Disk, Option X7522A 1GB DDR1 DIMM (×2) 30GB IDE Disk Drive System Board I/O Board Enclosure | Sun Fire B1600 Blade System Chassis |
| 540-5528 | 4GB B200x Blade w/ 30GB Disk, Option X7523A 1GB DDR1 DIMM (×4) 30GB IDE Disk Drive System Board I/O Board Enclosure | Sun Fire B1600 Blade System Chassis |
| 540-5547 | Sun Blade B100x w/ 512MB memory (1 × 512MB) | Sun Fire B1600 Blade System Chassis |
| 540-5548 | 1GB B100x Blade w/ 30GB Disk, Option X7512A 512MB DDR1 DIMM (×2) 30GB IDE Disk Drive System Board Memory Riser Enclosure | Sun Fire B1600 Blade System Chassis |
| 540-5549 | 2GB B100x Blade w/ 30GB Disk, Option X7513A 1GB DDR1 DIMM (×2) 30GB IDE Disk Drive System Board Memory Riser Enclosure | Sun Fire B1600 Blade System Chassis |
| 540-5554 | Network 2GB FC Switch-8 AC Y Power Cord (Option X319YA) Mounting Tray Right Mounting Rail (replaced by 565-1735) Left Mounting Rail (replaced by 565-1735) Tray Adapter Bracket Rear Bracket 2U Vented Panel Switch Assembly/FRU Hub Retainer 8-Port Switch Rack Mount Kit | Fibre Channel Sun StorEdge 3511 FC Array Sun StorEdge 3900/6900 Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Sun StorEdge L500 Sun StorEdge L8500 Tape Library Switches T3 |
| 540-5555 | Service Processor Accessory (SPA) Tray | Sun StorEdge 6320 System Sun StorEdge 6920 |
| 540-5558 | Service Processor Panel Assembly (Top) | Sun StorEdge 6320 System |
| 540-5559 | Sun StorEdge 6120/6920 RAID Controller Assembly | Fibre Channel Sun StorEdge 6020/6120 Array Sun StorEdge 6920 |
| 540-5559-03 | 3.0.3 | Firmware |
| 540-5559-04 | 3.0.7 | Firmware |
| 540-5560 | SCSI Backplane Mounting Bracket Assembly, L | Sun Fire V440 |
| 540-5562 | 36.4GB - 15000 RPM (Lucent), Disk Assembly with one of the following disks: | Disk (internal) Sun StorEdge 3310 T3 |
| 540-5563 | 73.4GB - 10000 RPM, Disk Assembly with 1 of the following disks: | Disk (internal) Sun StorEdge 3310 T3 |
| 540-5564 | 540-5565 | Sun Fire V1280 |
| 540-5565 | I/O Board and System Controller (IB_SSC) | I/O Sun Fire V1280 |
| 540-5591 | Option TA-EXPCAB-060 Ethernet Hub Brackets 340-7657/340-7658/340-7660 10/100 Ethernet Hub Expansion I/O Panel Main I/O Panel Assembly Panel Mount RJ45 Connector Main I/O Panel MPO/MPO FC Coupler LC Adapter DB9M to DB9F Adapter | Racks Sun StorEdge 6320 System |
| 540-5592 | I/O Panel Assembly (Bottom) | Sun StorEdge 6320 System |
| 540-5593 | Sun Fire B10n Option X8080A Sun Fire B10n Assembly/CRU Enclosure System Board Riser 512MB Memory | Sun Fire B1600 Blade System Chassis |
| 540-5596 | 8X DVD-ROM Drive Assembly, L | Removable Media Sun Fire V440 |
| 540-5603 | CPU/Memory Uniboard w/ 4× US III Cu 1.2GHz, 16GB | |
| 540-5604 | CPU/Memory Uniboard w/ 4× US III Cu 1.2GHz, 32GB | |
| 540-5605 | CPU/Memory Uniboard w/ 4× US III Cu 1.2GHz, 0MB | |
| 540-5621 | Chassis Subassembly | Sun Fire E2900 Sun Fire V1280 Sun Netra 1280 Server |
| 540-5623 | Sun Fire CPU/Memory Uniboard with 2 UltraSPARC III Cu 1050MHz, 8MB Ecache each, & 0MB Memory | |
| 540-5626 | 146GB - 10000 RPM FC-AL, Disk Assembly with one of the following disks: | Disk (internal) Sun StorEdge 3510 T3 |
| 540-5628 | 36.4GB - 15000 RPM FC-AL, Disk Assembly with one of the following disks: | Disk (internal) Sun StorEdge 3510 T3 |
| 540-5629 | 73.4GB - 10000 RPM FC-AL, Disk Assembly with one of the following disks: | Disk (internal) Sun StorEdge 3510 T3 |
| 540-5652 | 73GB 10000 RPM Disk Drive Option Assembly ( Option X5886A [S] ) 73GB 10000 RPM Disk Drive Assembly/FRU 73GB 10000 RPM Disk Drive Assembly (replaced 599-2652 in 3/03) Media Tray Sled 73GB 10000 RPM Disk Drive Assembly | Disk (internal) Sun StorEdge D2 T3 |
| 540-5661 | Chassis Assembly | Sun Netra 1280 Server |
| 540-5662 | CPU/Memory Uniboard w/ 4× US IV 1.05GHz, 16GB | |
| 540-5663 | CPU/Memory Uniboard w/ 4× US IV 1.05GHz, 32GB | |
| 540-5664 | 0MB FRU 4 × 1050MHz USIV 0MB 501-6520 November 2003 Jaguar 1050 | |
| 540-5665 | System Configuration Card Reader Assembly | Sun Fire E2900 Sun Fire V1280 Sun Netra 1280 Server |
| 540-5682 | CPU/Memory Uniboard w/ 2× US III Cu 1.2GHz, 4GB | |
| 540-5684 | CPU/Memory Uniboard w/ 4× US III Cu 1.2GHz, 4GB | |
| 540-5685 | CPU/Memory Uniboard w/ 4× US III Cu 1.2GHz, 8GB | |
| 540-5691 | CPU/Memory Uniboard w/ 2× US III Cu 1.2GHz, 0MB | |
| 540-5693 | 36.4GB - 10000 RPM, Disk Assembly (NEBS Level 3) with 1 bracket, and 1 of the following disks: | Disk (internal) Disks by Part Number Sun Netra t 1400 Sun Netra t 1405 Server T3 |
| 540-5694 | 73.4GB - 10000 RPM FC-AL, Disk Assembly (NEBS) with 1 bracket, 1 of the following plates, and 1 of the following disks: | Disk (internal) Disks by Part Number Sun Netra 20 T3 |
| 540-5698 | 36.4GB - 10000 RPM FC-AL, Disk Assembly (NEBS) with 1 bracket, 1 of the following plates, and 1 of the following disks: | Disk (internal) Disks by Part Number Sun Netra 20 T3 |
| 540-5699 | DVD-ROM Assembly/FRU ( Option X5883A [S] ) DVD-ROM Assembly (replaced 599-2396 in 3/03) Media Tray Sled 10x SCSI DVD-ROM, Medium Grey (540-5699-01) 6 16x ATAPI DVD-ROM, Medium Grey (540-5699-02) 6 | Removable Media Sun StorEdge D2 |
| 540-5699-01 | 595-5473 [F] 540-5699 340-6476 390-0025 390-0161 | Sun StorEdge D2 |
| 540-5699-02 | Toshiba SD-M1712 ATAPI/IDE Interface 1 5/8" Height Medium Grey Bezel | Removable Media Sun StorEdge D2 |
| 540-5699-03 | V890 Assembly/FRU No Option DVD 390-0287 Bracket 541-1325 | Removable Media |
| 540-5700 | 20-40GB 4 mm DDS-4 Assembly/FRU ( Option X5881A [S] ) 20-40GB 4 mm DDS-4 Assembly (replaced 599-2397 in 3/03) Media Tray Sled 20-40GB 4 mm DDS-4, Medium Grey | Removable Media Sun StorEdge D2 |
| 540-5701 | 18GB 10000 RPM Disk Drive Assembly/FRU ( Option X5880A [S] ) 18GB 10000 RPM Disk Drive Assembly (replaced 599-2398 in 3/03) Media Tray Sled 18GB 10000 RPM Disk Drive Assembly | Disk (internal) Sun StorEdge D2 T3 |
| 540-5702 | 36GB 10000 RPM Disk Drive Assembly/FRU ( Option X5884A [S] ) 36GB 10000 RPM Disk Drive Assembly (replaced 599-2593 in 3/03) Media Tray Sled 36GB 10000 RPM Disk Drive Assembly | Disk (internal) Sun StorEdge D2 T3 |
| 540-5703 | 73GB 10000 RPM Disk Drive Option Assembly ( Option X5886A [S] ) 73GB 10000 RPM Disk Drive Assembly/FRU 73GB 10000 RPM Disk Drive Assembly (replaced 599-2652 in 3/03) Media Tray Sled 73GB 10000 RPM Disk Drive Assembly | Disk (internal) Sun StorEdge D2 T3 |
| 540-5704 | Printed Circuit Board 541-1402 L | Sun Fire 12K / 15K Sun Fire 15K |
| 540-5708 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Switches |
| 540-5715 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Sun StorEdge 6920 Switches |
| 540-5718 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Sun StorEdge 6920 Switches |
| 540-5729 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Sun StorEdge 6920 Switches |
| 540-5730 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Sun StorEdge 6920 Switches |
| 540-5732 | CPU/Memory Uniboard w/ 4× US III Cu 1.2GHz, 8GB | |
| 540-5735 | 146.8GB - 10000 RPM, Disk Assembly with 1 of the following disks: | Disk (internal) Sun StorEdge 3310 Sun StorEdge 5210 NAS T3 |
| 540-5736 | Carrier Plate (Slots 4, 5, 13, 14) | |
| 540-5737 | Processor Cabinet (replaced 540-3985-09 - 02/03) | Sun Fire 12K / 15K Sun Fire 15K |
| 540-5740 | CPU/Memory Uniboard w/ 4× US III Cu 1.2GHz, 16GB | |
| 540-5741 | Sun Fire B10p Option X8025A Sun Fire B10p Assembly/CRU Enclosure System Board 512MB Memory | Sun Fire B1600 Blade System Chassis |
| 540-5755 | Fan Assembly | Sun Fire V60x |
| 540-5758 | Delta DPS-350PB -- 350 Watts | Power Supplies Sun Fire V60x |
| 540-5762 | Cable Kit | Sun Fire V60x |
| 540-5763 | 2U Cable Kit | Sun Fire V65x |
| 540-5764 | Compute Grid Base Assembly, Option A51-AA V60x Accessory Kit PS/2 Y Cable V60x Bezel Cable Harness Assembly Ethernet Cable Bundle Serial Cable Bundle Terminal Server to Switch Ethernet Cable Console Access to Switch Cable Sun Rack 900 EMI Containment Kit Sun Rack 900 Front Door Kit Sun Rack 900 with AC Power Distribution * | Sun Fire V60x Systems Sun Fire V60x Compute Grid |
| 540-5765 | 2U Bezel Assembly | Sun Fire V65x |
| 540-5767 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Sun StorEdge 6920 Switches |
| 540-5768 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Sun StorEdge 6920 Switches |
| 540-5768-05 | 2010-08-23 | Sun StorEdge 6920 |
| 540-5769 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Power Supplies Sun StorEdge 6920 Switches |
| 540-5770 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Sun StorEdge 6920 Switches |
| 540-5771 | 36.4GB 10000 RPM NEBS Disk Drive Assembly/FRU 73.4GB 10000 RPM NEBS Disk Drive Assembly/FRU 3 73.4GB 10000 RPM NEBS Disk Drive Assembly/FRU 3 73.4GB 15000 RPM NEBS Disk Drive Assembly/FRU 4 | Disk (internal) Sun Fire V120 Sun Netra 120 Sun Netra 1280 Server Sun Netra CT 410 Sun Netra CT 810 T3 |
| 540-5775 | Rack Bracket Spacer | Sun Fire B1600 Blade System Chassis |
| 540-5780 | CPU/Memory Uniboard w/ 4× US III Cu 1050MHz, 16GB | |
| 540-5784 | 1GB B100x Blade w/ 30GB Disk, Option X7512A 512MB DDR1 DIMM (×2) 30GB IDE Disk Drive System Board Memory Riser Enclosure | |
| 540-5786 | USB Relay Module Assembly | Sun StorEdge 6320 System Sun StorEdge 6920 |
| 540-5787 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Switches |
| 540-5788 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Switches |
| 540-5789 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Sun StorEdge 6920 Switches |
| 540-5790 | PSX-1000 Option SG-XPSX16A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip GBIC Kit Short Wave GBIC FRU Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU | Switches |
| 540-5792 | PSX-1000 Option SG-XPSX32A-2GB MIC Assembly/FRU SFC Assembly/FRU SIO FC8 Assembly/FRU Front Filler Assembly Rear Filler Assembly Chassis w Midplane Assembly/FRU SRC2 2GB Memory Assembly/FRU AC Power Supply Tray Assembly/FRU Fan Tray Assembly/FRU Accessory Kit IEC 320 to NEMA 5-15 AC Power Cord CAT5 Ethernet Cable DB9F to DB9F Null Modem Cable 19-inch Mounting Bracket Kit Cable Management Clip Flash Card Kit PCMCIA Flash Card 128MB PCMICA ATA FLASH FRU GBIC Kit Short Wave GBIC FRU | Switches |
| 540-5795 | CPU/Memory Uniboard w/ 2× US III Cu 1050MHz, 0MB | |
| 540-5796 | CPU/Memory Uniboard w/ 2× US III Cu 1050MHz, 2GB | |
| 540-5797 | CPU/Memory Uniboard w/ 2× US III Cu 1050MHz, 4GB | |
| 540-5798 | CPU/Memory Uniboard w/ 2× US III Cu 1050MHz, 8GB | |
| 540-5799 | CPU/Memory Uniboard w/ 4× US III Cu 1050MHz, 0MB | |
| 540-5800 | CPU/Memory Uniboard w/ 4× US III Cu 1050MHz, 4GB | |
| 540-5801 | CPU/Memory Uniboard w/ 4× US III Cu 1050MHz, 8GB | |
| 540-5803 | CPU/Memory Uniboard w/ 4× US III Cu 1050MHz, 32GB | |
| 540-5819 | CPU/Memory Uniboard w/ 4× US III Cu 1050MHz, 8GB | |
| 540-5820 | CPU/Memory Uniboard w/ 4× US III Cu 1050MHz, 16GB | |
| 540-5821 | CPU/Memory Uniboard w/ 2× US III Cu 900MHZ, 0MB | |
| 540-5822 | CPU/Memory Uniboard w/ 2× US III Cu 900MHZ, 2GB | |
| 540-5823 | CPU/Memory Uniboard w/ 2× US III Cu 900MHZ, 4GB | |
| 540-5824 | CPU/Memory Uniboard w/ 2× US III Cu 900MHZ, 8GB | |
| 540-5825 | CPU/Memory Uniboard w/ 4× US III Cu 900MHZ, 0MB | |
| 540-5826 | CPU/Memory Uniboard w/ 4× US III Cu 900MHZ, 4GB | |
| 540-5827 | CPU/Memory Uniboard w/ 4× US III Cu 900MHZ, 8GB | |
| 540-5829 | CPU/Memory Uniboard w/ 4× US III Cu 900MHz, 16GB | |
| 540-5830 | CPU/Memory Uniboard w/ 4× US III Cu 900MHz, 32GB | |
| 540-5849 | CPU/Memory UniBoard w/ 4× US III Cu 1200MHz, 0MB | |
| 540-5851 | Top Cover Assembly | Sun Netra 440 Server |
| 540-5852 | Chassis Assembly | Sun Netra 440 Server |
| 540-5853 | SCSI Disk Backplane Assembly/CRU | SCSI |
| 540-5854 | Netra 440 Power Distribution Board Assembly Board | Power Supplies Sun Netra 440 Server |
| 540-5855 | Blower Assembly | Sun Netra 440 Server |
| 540-5856 | System Configuration Card Reader Assembly | Sun Netra 440 Server |
| 540-5858 | CPU/Memory Uniboard w/ 4× US III Cu 1050MHz, 8GB | |
| 540-5859 | CPU/Memory Uniboard w/ 4× US III Cu 1.2GHz, 8GB | |
| 540-5860 | 0GB B100x Blade w/ 30GB Disk 30GB IDE Disk Drive System Board Memory Riser Enclosure | Sun Fire B1600 Blade System Chassis |
| 540-5862 | 0MB B200x Assembly/CRU 30GB IDE Disk Drive System Board I/O Board Enclosure | Sun Fire B1600 Blade System Chassis |
| 540-5863 | 1GB B200x Blade w/ 30GB Disk, Option X7521A 512MB DDR1 DIMM (×2) 30GB IDE Disk Drive System Board I/O Board Enclosure | |
| 540-5870 | CPU/Memory Board with 4 UltraSPARC III Cu 1200MHz, 16GB Memory | |
| 540-5872 | CPU/Memory Board with 4 UltraSPARC III Cu 1200MHz, 32GB Memory | |
| 540-5895 | StorEdge 6020/6120 Rack Mount Kit, Option X6876A [S] Rack Mount Rail Assembly (×2) 669.70 mm Rail 173.80 mm Rail Adapter | Racks Sun StorEdge 6020/6120 Array |
| 540-5897 | Chassis Sub Assembly | Sun Netra 440 Server |
| 540-5906 | Management Interface Card (MIC2) | Sun StorEdge 6920 |
| 540-5919 | Motherboard Assembly/CRU | |
| 540-5919-04 | 540-5919-06 | |
| 540-5919-06 | 540-5919-04/05 | |
| 540-5922 | 73.4GB - 15000 RPM FC-AL, Disk Assembly with Bracket and 1 disk: | Disk (internal) Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6920 T3 |
| 540-5923 | 73GB 15000 RPM Disk Drive Assembly | Disk (internal) Sun StorEdge D2 T3 |
| 540-5924 | 73.4GB - 15000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, L | Disk (internal) Sun Netra 240 Server Sun Netra 440 Server T3 |
| 540-5932 | Storage I/O Combo Card (SIO Combo) | Sun StorEdge 6920 |
| 540-5936 | 36.4GB - 10000 RPM, Disk Assembly with 1 of the following disks: | Disk (internal) Sun Fire V60x Sun Fire V65x T3 |
| 540-5937 | 73.4GB - 10000 RPM, Disk Assembly with 1 of the following disks: | Disk (internal) Sun Fire V60x Sun Fire V65x T3 |
| 540-5938 | CPU/Memory Uniboard w/ 4× US IV 1.2GHz, 16GB | |
| 540-5939 | CPU/Memory Uniboard w/ 4× US IV 1.2GHz, 32GB | |
| 540-5940 | 0MB FRU 4 × 1200MHz USIV 0MB 501-6520 November 2003 Jaguar 1200 ( see 12K/15K/E20K/E25K Notes below ) | |
| 540-5981 | CPU/Memory Board with 4 UltraSPARC III Cu 1200MHz, 8GB Memory | |
| 540-5984 | Patch Panel Assembly | Sun StorEdge 6920 |
| 540-5985 | Service Panel Assembly (top) | Sun StorEdge 6920 |
| 540-5986 | Main I/O Panel Assembly (middle) | Sun StorEdge 6920 |
| 540-5987 | I/O Panel Assembly (bottom) | Sun StorEdge 6920 |
| 540-5995 | Front Door Assembly | Sun Netra 440 Server |
| 540-5996 | 36.4GB - 10000 RPM, Disk Assembly with 1 Bracket and 1 of the following disks: | Disk (internal) Sun Blade 2500 T3 |
| 540-5997 | Fan Tray, Top I/O Area (FT1) | Sun Fire 4800 Sun Fire E4900 |
| 540-5998 | Fan Tray, Bottom Left I/O Area (FT0) | Sun Fire 4800 Sun Fire E4900 |
| 540-5999 | Fan Tray, Bottom Right I/O Area (FT2) | Sun Fire 4800 Sun Fire E4900 |