OSfOM

Class: Option | Series: F

<< Back to Series

Part NumberDescriptionAssociated Systems
F0005LED Board R0350-G0008-02SPARC T3-1 Server
F0014Riser-1 Assembly R0350-F0015-01 Bracket R0350-F0041-01 PCB R0350-G0002-02I/O
F0015Riser-2 Assembly R0350-F0016-01 Bracket R0350-F0042-01 PCB R0350-G0003-02I/O
F0016Riser FRU Riser 0, 1, and 2I/O
F0017LED Board R0350-G0008-02SPARC T3-1 Server
F0040Riser-1 Assembly R0350-F0015-01 Bracket R0350-F0041-01 PCB R0350-G0002-02I/O
F0041Riser-2 Assembly R0350-F0016-01 Bracket R0350-F0042-01 PCB R0350-G0003-02I/O
F0042Riser FRU Riser 0, 1, and 2I/O
F0044Mezzanine Board R0350-G0009-02I/O
F100550MHz UltraSPARC IIi FRU w/ Ground Ring 550MHz UltraSPARC IIi KFAB 650MHz UltraSPARC IIi KFAB (deviation WO_25102) 550MHz/DB650MHz UltraSPARC IIiSun Blade 150
Sun StorEdge A3500
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
T3
F150312389305 [F]
F180SR900/SR1000 Power Cord, Option X9237-1-A, 13A 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1.00M, SR900/SR1000 Power Cord, Option X9238-1-A, 13A 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2.50M,Racks
F240CPU Heatsink, MotherboardCPU Module
Sun Fire V250 Server
Sun Fire V440
F300450 Watt Power Supply,Sun Fire T2000
Sun SPARC Enterprise T2000
F310CPU Fan/Heatsink, Motherboard/MezzanineCPU Module
F330Floppy/Disk/Tape Foam FRU Foam, Left Side of Floppy/Disk/Tape Foam, Right Side of Floppy/Disk/TapeSun Netra 1280 Server
Sun Netra 1280 Server, RoHS:YL
Sun Netra 1290, RoHS:YL
Sun Netra 150 / E150
F3480S1/2" Desktop Cartridge Tape DriveSun4d System Cray Superserver 6400
F370Service diagnostic cables (F370-4119-01) for the StorEdge T3 Array are miswired and may not work. The F370-4119-01 part is a serial maintenance cable used to connect the T3 Array to a terminal or host port connection and provide capability to diagnose complex failure conditions. This problem will impact all field service engineers who have T3 diagnostic cables in their possession. Some diagnostic cables (F370-4119-01) may be miswired and will not function properly. These affected cables were distributed worldwide. The approximate number of distributed cables in each geo are: 60 in Americas, 50 in APAC, and 50 in EMEA.Memory
Sun Blade 1500
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire V20z
Sun Fire V210
Sun Fire V240
Sun Fire V40z
Sun Netra 150 / E150
Sun Netra 240 Server
T3
F371Ship Kit IEC 320 C13 to IEC 320 Sheet E, 10A/250V, 1.0M DB-9F / RJ-45 Serial Adapter RJ45F to DB9F Adapter RJ45 to RJ45 Shielded Ethernet Cable, CAT5, 2M Fibre Channel Optical Cable LC/LC, 5MI/O
Removable Media
SCSI
Sun Fire E2900
Sun Fire E2900, RoHS:YL
Sun Fire V1280
Sun Fire V240
Sun Modular Datacenter S20 / D20
Sun Netra 1280 Server
Sun Netra 1280 Server, RoHS:YL
Sun Storage 6580/6780
Sun Ultra 25
Sun Ultra 45
Switches
F373LIM FRU w/o Pad w/o Optics, L LIM w/o Pad w/o OpticsSun Ultra 25
Sun Ultra 45
Switches
F375Sun Fire x800 systems are subject to a "panic" problem at boot time when a cPCI Dual FC Network Adapter (FRU or X-option) is installed for the first time. If a customer installs this board and boots the system, they will see panic messages on the console and the boot will fail. However, any subsequent reboots will be successful. This may result in an unnecessary service call. This cPCI board (P/N 370-0118-02) has been shipped with Sun Fire X800 systems and as an X-option. The current estimate is that less than 1000 boards have been installed in systems and 1200 boards are in field stock (FRUs and x-options) as of 7/12/01.Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
F3808-Slot SDLT600 Autoloader, Option SG-XAUTO8SDLT6-C2Z 8-Slot SDLT600 Autoloader FRU, Quantum EC-SF2CA-HW 8-Slot SDLT600 Autoloader Base, Quantum EC-SF2CA-HW 8-Slot SDLT600 Autoloader Base, Quantum ER-SF2CA-HW Ultra-320 SCSI Cable, 2M, Quantum 17-80192-01 Power Cord, 1.9M, Quantum 17-80187 1 LVD/SE Terminator, Quantum 0455213 Rackmount Kit, Quantum 70-87053-01 2Fibre Channel
Removable Media
Sun Ray
Sun StorEdge C4 Library
Sun StorageTek C4 Library, RoHS:YL
Systems StorEdge C2 Tape Autoloader
F3800Sun Fire 3800Sun Fire 3800
F3800ELucent A145 Type A145 AC Input Power Supply Option 4303Power Supplies
Sun Fire 3800
F390Slimline 8X DVD-Writer / 24X CD-Writer,Removable Media
Sun Fire V490
F4089Capacity On Demand (COD) Uniboard w/ 4× unlicensed US III Cu 900MHz, 8GB
F4169540-4990
F420Sony MP-F420-6-A10 Sun-4/15/30/40/50 SS4 / SS5 / SS20 8 mm Black BezelRemovable Media
F4329540-4993
F455I3 Phase P/S(DKC-F460I-3PSD)72GB 15K RPM drives in Sun StorEdge[TM] 9970/80 System give fewer LDEVs than expected
F460I3 Phase P/S(DKU-F455I-3PSD)
F4800Sun Fire 4800Sun Fire 4800
Sun Fire E4900
F4810Sun Fire 4810Sun Fire 4800
Systems Sun Fire 4810
F501SAS Cable Board Assembly (PCI-X), LI/O
Sun Blade 1000
Sun Fire 3800
Sun Fire V445
Sun Fire V480
Sun Netra 20
F5100StorageTek Oracle Key Manager Sun StorageTek Crypto Key Management Station Sun StorageTek SL24, RoHS:YL Sun StorageTek SL3000 Sun StorageTek SL48, RoHS:YL Sun StorageTek SL500,RoHS:YL Sun StorageTek SL8500, RoHS:YL Tape Virtualization Sun StorageTek Virtual Library Extension Sun StorageTek Virtual Storage ManagerPower Supplies
SCSI
Sun Storage F5100 Field Action Bulletins
Sun Storage F5100 Flash Array
Sun Storage F5100 How Tos
Sun Storage J4000 Series Arrays with Common Array Manager (CAM) Firmware Matrix
Sun Storage J4200 How Tos
Sun Storage J4400 How Tos
Sun Storage J4500 How Tos
Sun StorageTek[TM] 6140 Firmware Matrix
Sun StorageTek[TM] 6540 Firmware Matrix
Sun Storage[TM] 6180 Firmware Matrix
Sun Storage[TM] 6580/6780 Firmware Matrix
Systems List
F510I8GB Cache Memory Module OptionFibre Channel
Memory
Sun StorEdge 9985
Sun StorEdge 9990
F511Package of 25 × 512MB SDRAM DIMMsMemory
Sun Blade 1000
Sun Blade 2000
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V1280
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
F515IWeight 5Sun StorEdge 9985 System Hardware Specifications
F527550MHz UltraSPARC IIi FRU w/ Ground Ring 550MHz UltraSPARC IIi KFAB (deviation WO_26984/WO_27317) 550MHz UltraSPARC IIi DMOS4 550MHz UltraSPARC IIi DMOS4Sun Blade 150
F530RJ45 to RJ45 CAT5E Ethernet Cable, 2M RJ45 to RJ45 CAT5E Ethernet Cable, 2M (replaced 530-3633) RJ45 to RJ45 CAT5E Ethernet Cable, 1M RJ45 to RJ45 CAT5E Ethernet Cable, 6M RJ45 to RJ45 CAT5E Ethernet Cable, 6M (replaced 530-3794)Sun Blade 100
Sun Blade 150
Sun Fire T2000
Sun SPARC Enterprise T5120 Server
Sun SPARC Enterprise T5220 Server
Sun Storage 6580/6780
Sun StorageTek 5800
Sun Ultra 10
F537Ship Kit IEC 320 C13 to IEC 320 Sheet E, 10A/250V, 1.0M DB-9F / RJ-45 Serial Adapter RJ45F to DB9F Adapter RJ45 to RJ45 Shielded Ethernet Cable, CAT5, 2M Fibre Channel Optical Cable LC/LC, 5MSun Storage 6580/6780
F540DDR266/333, PC2100/2700 ECC, SPD 0.0 or 1.0 2GB Registered DIMM 4GB Option 7711 8GB Option 5504 4GB FRU F540-6402 Only supported on: SB1500 (Silver) SB2500 (Silver) Netra 440 Sun Fire V440 See 370-7672 directly belowMemory
Sun Blade 1500
Sun Fire V20z
Sun Netra 1290, RoHS:YL
Sun Netra T5440
Sun Storage 7110
Sun Storage 7310
Sun Storage 7310 (SAS 2.0)
Sun Storage 7410
Sun Storage 7410 (SAS 2.0)
Sun StorageTek 5800
Sun StorageTek Virtual Tape Library Prime Storage Appliance, RoHS:YL
Sun Ultra 25
F541500GB SATA Disk Drive Assembly/FRU 500GB SATA Disk Drive, Hitachi 500GB SATA Disk Drive, Hitachi Drive Mounting BracketMemory
Removable Media
SPARC T3-4 Server
Sun Blade 6000
Sun Fire V445
Sun Storage 6580/6780
Sun StorageTek 5220 NAS, RoHS:YL
Sun StorageTek 5800
Sun ZFS Storage 7720
F54218GB SAS Solid State Drive Assembly {PKG}Exadata
Sun Storage 7310 (SAS 2.0)
Sun Storage 7410 (SAS 2.0)
Sun ZFS Storage 7120
Sun ZFS Storage 7320
Sun ZFS Storage 7420
Sun ZFS Storage 7720
F560CMA-800 Cable Management FRU,Sun Fire E2900
Sun Fire E2900, RoHS:YL
Sun Fire V1280
Sun Netra 1280 Server
Sun Netra 1280 Server, RoHS:YL
Sun Netra 1290, RoHS:YL
F570Disk Node FRU without Disk Drives Power Supply 1 Disk Node Chassis Assembly 1 Tyan S2865 Motherboard with 2.2GHz Opteron 148 Heatsink and Air Baffle 343745400004 Tyan M3290 Service Processor FDK CR2032 Battery Tyan M1204 4-Slot Disk Backplane Tyan M1003 LED/Switch/USB Board Tyan M1013 Adapter Board Motherboard J46 to Service Processor Cable 422745400008 Motherboard J45 to Adapter Board Cable 422750300006 Motherboard J45 Pins 16/18 to Interlock Switch and Cable Motherboard J34 to LED/Switch/USB Board Cable 422750300008 SATA Cable 422741900008 CPU Fan/Fan3 Cable 422750300009 Fan1/Fan2 Cable 4227470900004 Rear Locate LED Cable 422750300005 Adapter Board to SATA Backplane Cable 42275030004 Five Fan Kit 1 Fan 512MB DDR400/PC3200 Unbuffered DIMM 1GB DDR400/PC3200 Unbuffered DIMM ST5800 Rackmount KitSun StorageTek 5800
F594Service Processor Assembly/FRU 6 7 Sun Fire X2100 M2 ATO Base Assembly 512MB Unregistered ECC DDR2-667/PC5300 DIMM 4 1.8GHz Dual Core Opteron 1210 5 CPU Heatsink 8x DVD-ROM / 24x CD-ROM System Board 250GB 7200 RPM SATA Disk Drive AssemblySun StorageTek 5800
F595375-3295
F602Service Processor Assembly/FRU 7 Sun Fire X2100 Base Assembly 1GB DDR400/PC3200 Unbuffered ECC DIMM 3 2.2GHz Opteron 148 Socket 939 (E4 Stepping) CPU Heatsink 8x DVD-ROM / 24x CD-ROM System Board Service Processor 80GB 7200 RPM SATA Disk Drive Assembly 80GB 7200 RPM SATA Disk Drive AssemblySun StorageTek 5800
F605I371-4167Sun StorageTek 9985V System
Sun StorageTek 9990V System
F6101n/aMemory
F610I371-4166Communication
Fibre Channel
Memory
Sun StorageTek 9985V System
Sun StorageTek 9990V System
F6151HeightSun StorageTek 9985V System, RoHS:YL Hardware Specifications
F615I371-3854Communication
Fibre Channel
Memory
Sun StorageTek 9985V System
Sun StorageTek 9985V System, RoHS:YL Hardware Specifications
Sun StorageTek 9990V System
F6800595-5798 540-4446 [F] 540-4764 375-0093 [F] 501-6094 [F] 370-4224 501-5629Sun Fire 6800
Switches