Parts for System: Allgemein / Unbekannt
| Part Number | Description | Associated Systems |
|---|---|---|
| 370-2303 | This FIN is to inform the field of a new style GBIC that will be shipping with A5X00 Storage Arrays. Installing a FINISAR GBIC in any platform other than A5X00 will result in a restricted access condition which may result in unanticipated downtime. | Allgemein / Unbekannt Disk (external) Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 Sun Ultra 2 T3 |
| 375-0094-01 | VRM Interposer board (375-0094-01) can cause intermittent system resets in the Enterprise 220R under high-load conditions. | Allgemein / Unbekannt Sun Enterprise 220R |
| 501-1850-02 | 1996-11-21 | Allgemein / Unbekannt Sun Ultra 2 |
| 501-4450-11 | System Board (501-4450-10/11) | Allgemein / Unbekannt Sun Ultra 60 |
| 501-5658 | 2 GB (8 × 256MB DIMMs) | Allgemein / Unbekannt Memory Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-5727-04 | PCI Cassette Card | Allgemein / Unbekannt Sun Fire 12K / 15K Sun Fire 15K Archived FINs and FCOs |
| 501-6718 | 256MB DIMM w/ GAL | Allgemein / Unbekannt Memory Sun Netra t 1400/1405 Repair Procedures Sun Ultra 80 |
| 540-4591-02 | Sunfire 3800 systems with 540-4591-02 (or lower) cPCI I/O Assemblies will not support Hot Swapping of cPCI cards. | Allgemein / Unbekannt Sun Fire 3800 |
| X1049A | QFE Sbus Card (501-4837-02) | Allgemein / Unbekannt Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1058A | QEC SBus Card (501-2062) | Allgemein / Unbekannt Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X6286A | D.C. Power Cable (530-2864-02), DDS-3 tape drive | Allgemein / Unbekannt Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R |
| X6541A | SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected. | Allgemein / Unbekannt SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X6600A | 375-0005 [F] | Allgemein / Unbekannt Sun Enterprise 450 |
| X6727A | Origin: On X6727A (375-3030) Card - P3 to J3(TX); P4 to J4(RX) Destination: On Expansion Backplane - C to J01100, D to J01101 | Allgemein / Unbekannt Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| X6757A | A potential for data loss exists with SBus Fibre Channel Adapters (6757A) attached to Sun StorEdge 99xx arrays or to Fibre Channel Tape drives in specific configurations. | Allgemein / Unbekannt Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 9910/9960 Sun StorEdge 9970/9980 Array Field Information Notices Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge L5500 |
| X7418A | 370-6455 [F] | Allgemein / Unbekannt Sun Fire V210 |