Parts for System: Sun Enterprise 10000
| Part Number | Description | Associated Systems |
|---|---|---|
| 300-1290 | 56-inch Enterprise Expansion Cabinet Assembly Universal Power Sequencer Fan Tray Assembly Fan Tray Rear Cover Top Panel, Medium Grey Side Panel, Medium Grey Keyswitch Assembly Door Assembly AC Power Cord, Harting Han 6HsB to NEMA L6-30P AC Power Cord, Harting Han 6HsB to IEC 309 | Racks Sun Enterprise 10000 Sun Enterprise 5000/6000 Data Center Cabinet Sun Enterprise 5500 Sun Enterprise 6000 Sun Enterprise 6500 Sun SPARCstorage Array Systems Disk Array Options StorEdge A3000 Rack Systems Enterprise 5000 T3 |
| 300-1290-02 | Power sequencer and power cords are non-compliant with safety standard UL1950/EN60950. | Sun Enterprise 10000 |
| 300-1336 | Sun Type A135 2000 Watt Power Supply | Power Supplies Sun Enterprise 10000 |
| 300-1368 | Sun Type A135 2000 Watt Power Supply | Power Supplies Sun Enterprise 10000 |
| 300-1403 | 68" Cabinet Sequencer Option X9620A Universal Power Sequencer Ground Cable IEC 320 to AMP Mate-N-Lok Power Cord Remote Keyswitch Control Cable, 3.2M Expansion Rack Dual Sequencer Keyswitch Y Cable Power Sequencer Installation Guide | Racks Sun Enterprise 10000 Sun Enterprise 5000/6000 Data Center Cabinet Sun Enterprise 5500 Sun Enterprise 6000 Sun Enterprise 6500 Systems Enterprise 5000 |
| 300-1430 | Sun Type A135 2000 Watt Power Supply | Power Supplies Sun Enterprise 10000 |
| 330-1265 | SBus Accessory Kit Bracket (×5) Handle (×5) | Sun Enterprise 10000 |
| 340-2348 | SBus Accessory Kit Bracket (×5) Handle (×5) | Graphics Sun Enterprise 10000 |
| 340-4288 | StorEdge D240 Center FRU 12-Slot A1000/D1000 FRU w 1" Bracket 540-3024 w Plate 340-4288 or 340-6640 or Plate 340-5928 or 340-7269 | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 3500 Sun Fire E2900 Sun Fire V120 Sun Netra 120 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge N8200 T3 |
| 340-4526 | Flat Side Panel (Option 9693) Flat Side Panel without Logo | Sun Enterprise 10000 |
| 340-4537 | Right Front/Rear Door Front/Rear Door Foam Air Filter | Sun Enterprise 10000 |
| 340-4538 | Flat Side Panel (Option 9693) Flat Side Panel without Logo | Sun Enterprise 10000 |
| 340-5928 | Netra ct/st/CT/T1/120 FRU NEBS Level 2/3 w 1" Bracket 540-3024 w Plate 340-4288 or Plate 340-6640 or Plate 340-5928 or Plate 340-7269 | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 3500 Sun Fire 280R Sun Fire E2900 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V250 Server Sun Netra 120 Sun Netra 1280 Server Sun Netra 240 Server Sun Netra 440 Server Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun StorEdge S1 T3 |
| 340-6640 | StorEdge D240 Center FRU 12-Slot A1000/D1000 FRU w 1" Bracket 540-3024 w Plate 340-4288 or 340-6640 or Plate 340-5928 or 340-7269 | Disk (internal) Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 3500 Sun Fire 280R Sun Fire E2900 Sun Fire V120 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 120 Sun Netra 20 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge N8200 T3 |
| 340-7269 | Netra ct/st/CT/T1/120 FRU NEBS Level 2/3 w 1" Bracket 540-3024 w Plate 340-4288 or Plate 340-6640 or Plate 340-5928 or Plate 340-7269 | Disk (internal) Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 3500 Sun Fire 280R Sun Fire E2900 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V250 Server Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 120 Sun Netra 1280 Server Sun Netra 20 Sun Netra 240 Server Sun Netra 440 Server Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun StorEdge S1 T3 |
| 350-1153 | Curved Side Panel ("Styling Panel") Curved Side Panel without Logo | Sun Enterprise 10000 |
| 350-1184 | Curved Side Panel ("Styling Panel") Curved Side Panel without Logo | Sun Enterprise 10000 |
| 370-1703 | When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver. | MediaCenter Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L3500 Sun StorEdge L7 Sun StorEdge L9 Sun StorEdge S1 Sun Ultra 2 |
| 370-1704 | When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L20 / L40 / L60 Sun StorEdge L3500 Sun StorEdge L7 Sun StorEdge L9 Sun Ultra 2 |
| 370-2303 | This FIN is to inform the field of a new style GBIC that will be shipping with A5X00 Storage Arrays. Installing a FINISAR GBIC in any platform other than A5X00 will result in a restricted access condition which may result in unanticipated downtime. | Allgemein / Unbekannt Disk (external) Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 Sun Ultra 2 T3 |
| 370-2343 | RSM with 3× 4.2GB Disk Drives RSM with 7× 4.2GB Disk Drives SPARCstorage RSM Chassis FRU 4.2GB 5400 RPM Disk Drive Assembly/FRU 4.2GB 7200 RPM Disk Drive Assembly/FRU SPARCstorage RSM Rack Mount Tray SPARCstorage RSM Shipping Bracket External SCSI Cable, HD68 to HD68, 2.0M AC Power Cord, AMP Mate-N-Lok to IEC-320 Remote Keyswitch Control Cable, 3.2M AC Power Cord, AMP Mate-N-Lok to Y IEC-320 Fibre Optical Cable, 2M Fibre Optical Cable, 15M | Sun Enterprise 10000 Sun SPARCstorage Array Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 T3 |
| 370-2443 | When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver. | SCSI Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun Ultra 2 |
| 370-2443-01 | Intermittently, SCSI devices connected to a UDWIS card may not be usable after a reboot. This can prevent a system from booting if the UDWIS card connected to the boot device is affected. This problem is due to some issues in FCode versions less than 1.28 in the UDWIS card. When it is booting, the card fails to send a SCSI bus reset, or the SCSI bus reset is not held long enough to meet the SCSI specification, or the card fails to initialize correctly. This leads to the attached SCSI devices failing to negotiate correctly with the host. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L3500 Sun StorEdge L7 |
| 370-2443-02 | Any system installed with a UDWIS/S (isp-fcode 1.28) has the possibility of displaying "invalid command" messages during POST, "probe-scsi-all" at the ok prompt, booting IF the variable "diag-switch?" is set to "true", or boot -hv from external storage.. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L3500 Sun StorEdge L7 |
| 370-2845 | Card Cage Air Filter Card Cage Air Filter Kit with 8× 370-2845 | Sun Enterprise 10000 |
| 370-2868 | Scalable Coherent Interface (SCI) Card Scalable Coherent Interface (SCI) Card SCI Cable, 80-Pin to 80-Pin, 2M SCI Cable, 80-Pin to 80-Pin, 5M SCI Cable, 80-Pin to 80-Pin, 10M SCI Cable with Ferrites, 80-Pin to 80-Pin, 2M SCI Cable with Ferrites, 80-Pin to 80-Pin, 5M SCI Cable with Ferrites, 80-Pin to 80-Pin, 10M | Communication Sun Enterprise 10000 Sun SPARCcluster |
| 370-2868-01 | SCI cards installed in E10000 systems may not initialize properly. | Sun Enterprise 10000 |
| 370-2887 | Centerplane Removal Handle Set | Sun Enterprise 10000 |
| 370-3142 | FDDI/S SAS 5.0 HW/SW Assembly FDDI/S SAS 6.0 HW/SW Assembly Network Peripherals FDDI/S SAS Fiber Card (obs) Network Peripherals FDDI/S SAS Fiber Card Cable Assembly MIC to MIC Coupler 3 Meter FDDI Cable, SC Duplex to MIC | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 370-3143 | FDDI/S DAS 5.0 HW/SW Assembly FDDI/S DAS 6.0 HW/SW Assembly Network Peripherals FDDI/S DAS Fiber Card (obs) Network Peripherals FDDI/S DAS Fiber Card 3 Meter FDDI Cable, Type SC to MIC (obs) Cable Assembly MIC to MIC Coupler 3 Meter FDDI Cable, SC Duplex to MIC | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 370-3795 | Hub Assembly/FRU (replaced 540-3584) | Ethernet Sun Enterprise 10000 |
| 370-3878 | HIPPI/P 1.0/1.1 SC Duplex 50/125 Multimode Fibre Optical Cable, 15M SC Duplex 50/125 MM Cable, 2M (alternate for 370-3879) SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 MM Cable, 15M (alternate for 370-3879) | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 4800 Sun Fire 6800 |
| 370-4273 | Enterprise System Interface (ESI/P) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 375-0002 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Enterprise 10000 Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 |
| 375-0003 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 375-3019 | PCI Single FC Host Adapter (use for 9840 FC drives) | Fibre Channel Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-3030 | Origin: On X6727A (375-3030) Card - P3 to J3(TX); P4 to J4(RX) Destination: On Expansion Backplane - C to J01100, D to J01101 | Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-3048 | A potential for data loss exists with SBus Fibre Channel Adapters (6757A) attached to Sun StorEdge 99xx arrays or to Fibre Channel Tape drives in specific configurations. | Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 9910/9960 Sun StorEdge 9970/9980 Array Field Information Notices Sun StorEdge 9990 Sun StorEdge L5500 |
| 375-3048-01 | In some configurations, after a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging of the FC cable at the FC hub, the SOC+ HBA might intermittently take the FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) received on an idle port of a SOC+ HBA can disrupt I/O activity on the second port of that HBA. | Firmware Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 375-3102 | 2GB PCI Single FC Network Adapter | Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-3108 | 2Gb PCI/PCI-X Dual FC Host Adapter | Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire T2000 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-3383 | 2Gb PCI-X Single FC Host Adapter, | Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire T2000 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V245 Sun Fire V440 Sun Fire V445 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L700 Sun Ultra 25 Sun Ultra 45 Sun Ultra 60 Sun Ultra 80 T3 |
| 390-0002 | 18.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LC | Disk (external) Disks by Part Number SCSI Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire V120 Sun Netra 120 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun Ultra 60 Sun Ultra 80 T3 |
| 390-0006 | 36.4 GB Wide SCSI Disk Card with 2× 18.2GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 18.2GB 10000 RPM Disk Drive FRU 18.2GB Disk Drive, Seagate ST318203LC 18.2GB Disk Drive, Fujitsu MAG3182LC 18.2GB Disk Drive, Seagate ST318404LC 18.2GB Disk Drive, Fujitsu MAJ3182MC | Disk (internal) Disks by Part Number SCSI Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun Ultra 60 Sun Ultra 80 |
| 390-0038 | 18.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LC | Disk (external) Disks by Part Number SCSI Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 15K Sun Fire V120 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun Ultra 60 Sun Ultra 80 T3 |
| 390-0043 | 36.4 GB Wide SCSI Disk Card with 2× 18.2GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 18.2GB 10000 RPM Disk Drive FRU 18.2GB Disk Drive, Seagate ST318203LC 18.2GB Disk Drive, Fujitsu MAG3182LC 18.2GB Disk Drive, Seagate ST318404LC 18.2GB Disk Drive, Fujitsu MAJ3182MC | Disk (internal) Disks by Part Number SCSI Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 15K Sun Fire V120 Sun Netra 120 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun Ultra 60 Sun Ultra 80 |
| 390-0048 | IBM DDYS-T18350 [DDYST1835SUN18G] (18.2GB - 10000 RPM - SCSI Disk) | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire V120 Sun Netra 120 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun Ultra 60 Sun Ultra 80 |
| 390-0050 | 18.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LC | Disk (external) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra 120 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun Ultra 60 Sun Ultra 80 T3 |
| 390-0051 | Netra ct/st/CT/T1/120 FRU NEBS Level 3 w 1" Bracket 540-3024 w Plate 340-4288 or 340-6640 or Plate 340-5928 or 340-7269 | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra 120 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun Ultra 60 Sun Ultra 80 |
| 390-0052 | IBM DDYS-T36950 [DDYST3695SUN36G] (36.4GB - 10000 RPM - SCSI Disk) | Disks by Part Number Sun Enterprise 10000 Sun Fire V120 Sun Netra 120 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 T3 |
| 390-0060 | 18.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LC | Disk (external) Disk (internal) Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra st D130 Disk Sun Netra t 1400/1405 Disks Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge N8200 Sun Ultra 60 Sun Ultra 80 |
| 390-0065 | Fujitsu MAN3367MC [MAN3367M SUN36G] (36.4GB - 10000 RPM - SCSI Disk) | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Fire V1280 Sun Netra 120 Sun Netra 1280 Server Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge S1 Sun Ultra 60 Sun Ultra 80 |
| 390-0066 | Fujitsu MAN3184MC [MAN3184M SUN18G] (18.2GB - 10000 RPM - SCSI Disk) | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun StorEdge S1 Sun Ultra 60 Sun Ultra 80 |
| 390-0069 | 18.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LC | Disk (external) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Fire V1280 Sun Netra 120 Sun Netra 1280 Server Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge 3310 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge S1 Sun Ultra 60 Sun Ultra 80 T3 |
| 390-0085 | 18.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LC | Disk (external) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 15K Sun Fire V120 Sun Netra 120 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun StorEdge S1 Sun Ultra 60 Sun Ultra 80 T3 |
| 390-0109 | 18.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LC | Disk (external) Disks by Part Number Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V250 Server Sun Fire V440 Sun Netra 120 Sun Netra 1280 Server Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge 3310 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge S1 Sun Ultra 60 Sun Ultra 80 T3 |
| 407-6575 | A few defective covers have been identified on the Ultra Enterprise 10000 system boards. The cover is missing a clearance hole for a centerplane guidepin. This is ONLY needed for slot 07 on the UE10000, all other slots do not require this clearance hole. | Sun Enterprise 10000 |
| 500-4779 | PCI I/O FRU Assembly 500-5126 3.3V Riser Kit 565-1474 | I/O Sun Enterprise 10000 |
| 501-1725 | SBus High Speed Serial Interface (HSI/S) Interface Cable, SBus Card to Interface Panel, 2.0M 19" Wide Rack Mounting Bracket Wall Mounting Bracket Sun 56" Rack Mounting Bracket SBus Mounting Screw Adapter Bracket HSI/S Loopback Test Plug, 96-Pin High-Density RS-530 Loopback Test Plug, 25-Pin (obsolete) RS-449 Loopback Test Plug, 37-Pin 4-Channel RS-530 Interface Panel (obsolete) RS-530 Interface Panel PCB 4-Channel RS-449 Interface Panel RS-449 Interface Panel PCB | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-1849 | SBus SunISDN-BRI/SBI SBus SunISDN-BRI/SBI (BABT, ETSI-1, and AU-1 approved) RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-1902 | Differential SCSI Host and Buffered Ethernet DSBE/S SCSI Connector Screw, #2-56 × 1/4" SCSI Connector Standoff, #2-56M - #2-56F (obsolete) SCSI Connector Standoff, #2-56M - #2-56F, Slotted | Ethernet SCSI Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-1931 | SBus Serial Parallel Controller (SPC/S) SBus Serial Parallel Controller (SPC/S) 19" Wide Rack Mounting Bracket Wall Mounting Bracket Sun 56" Rack Mounting Bracket SBus Mounting Screw Adapter Bracket 8-Channel Interface Panel RS-232 Loopback Test Plug, 25-Pin SPC/S Loopback Test Plug, 96-Pin High-Density Interface Cable, SBus Card to Interface Panel, 2.0M | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-1932 | 4MB/Sec Token Ring Interface (TRI/S) 4/16MB/Sec Token Ring Interface (TRI/S) The TRI/S requires a DB-9 connector compatible with IBM interface cables of Type-1 or Type-2 specifications. Use IBM part number 6339098. Cables are not available from Sun. | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-2015 | Order Number SMC20-712-330 SPARCstation 20 Model 712 8.4GB Multi-Disk Pack Option 739 (×2) External Active Terminator, HD50 MediaCenter 20 Nameplate Fast SCSI/EThernet FSBE/S Option 1053 (×2) Fast SCSI/EThernet FSBE/S Option 1053 (×2) SunATM-155/MFiber 2.0 Adapter Option 1060 External SCSI Cable, HD50 to HD50, 45 cm | Ethernet MediaCenter SCSI Sun Enterprise 10000 Sun Enterprise 3000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6000 Sun Enterprise 6500 Sun Ultra 2 Systems Enterprise 4000 Systems Enterprise 5000 |
| 501-2062 | Quad Ethernet (QEC/S) Quad FastEthernet 1.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-2553 | Configured SBus Optical Channel Host Adapter Filler Panel Fibre Channel Optical Module SBus Optical Channel Host Adapter (SOCHA or FC25/S) | Fibre Channel Sun Enterprise 10000 |
| 501-2603 | SBus SunISDN-BRI/SBI SBus SunISDN-BRI/SBI (BABT, ETSI-1, and AU-1 approved) RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-2653 | 256 MB (8 × 32MB DIMMs) | Memory Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-2653-01 | DIMMs are being unnecessarily replaced on Enterprise 10000 servers. | Sun Enterprise 10000 |
| 501-2654 | 1 GB (8 × 128MB DIMMs) | Memory Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-2654-01 | DIMMs are being unnecessarily replaced on Enterprise 10000 servers. | Sun Enterprise 10000 |
| 501-2739 | SunSwift SCSI/Ethernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet SCSI Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3120 Sun StorEdge 3310 Sun StorEdge S1 Sun Ultra 2 |
| 501-2739-05 | Enterprise 10000 systems with (SunSwift) Cards could experience intermittent but fatal errors at power up. | Sun Enterprise 10000 |
| 501-2794 | Order Number SMC1000E-614-460 SPARCserver 1000E SPARCstorage Array (Single-Ended SCSI) 2.1GB 7200 RPM Disk Drive FRU Assembly SCSI Interconnect Board Assembly/FRU SCSI Interconnect Board SCSI Interconnect Daughter Board SWIS/S Option 1063 (×6) SunATM-155/MFiber 2.0 Option 1060 (×4) External SCSI Cable, HD68 to HD68, 80 cm | Communication MediaCenter Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-2794-08 | SunATM-155 SBus board replacement may render interface unrecognizable. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-2795 | SunATM-155/UTP5 1.0 SunATM-155/UTP5 2.0 RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-2795-06 | SunATM-155 SBus board replacement may render interface unrecognizable. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-2864 | SunATM-155/MFiber 2.0/2.1/4.0 SunATM-155/MFiber 2.0/2.1/4.0 SunATM-622/MFiber 2.1/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-2919 | Order Number SMC-A14-167-500 Ultra 2 Model 2170 SPARCstorage MultiPack, Option 5503 (×2) Single-Ended Forced Perfect Terminator, HD68 SWIS/S, Option 1063 (×2) SunATM-155/MFiber 2.0, Option 1060 SunFastEthernet 2.0, Option 1059 External SCSI Cable, HD68 to HD68, 80 cm 4.2GB 5400 RPM Disk Drive Assembly | Ethernet MediaCenter Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-2981 | Order Number SMC20-712-330 SPARCstation 20 Model 712 8.4GB Multi-Disk Pack Option 739 (×2) External Active Terminator, HD50 MediaCenter 20 Nameplate Fast SCSI/EThernet FSBE/S Option 1053 (×2) Fast SCSI/EThernet FSBE/S Option 1053 (×2) SunATM-155/MFiber 2.0 Adapter Option 1060 External SCSI Cable, HD50 to HD50, 45 cm | Ethernet MediaCenter Sun Enterprise 10000 Sun Enterprise 3000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6000 Sun Enterprise 6500 Sun Ultra 2 Systems Enterprise 4000 Systems Enterprise 5000 |
| 501-3027 | SunATM-155/UTP 3.0/4.0 SunATM-155/MFiber 3.0/4.0 SunATM-622/MFiber 3.0/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3028 | SunATM-155/UTP 3.0/4.0 SunATM-155/MFiber 3.0/4.0 SunATM-622/MFiber 3.0/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3029 | SunATM-155/UTP 3.0/4.0 SunATM-155/MFiber 3.0/4.0 SunATM-622/MFiber 3.0/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3060-06 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 |
| 501-4178 | 250MHz UltraSPARC II Module (1MB Cache Blackbird) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4249 | 250MHz UltraSPARC II Module (4MB Cache Blackbird) SRAM 100-5528 | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4345-04 | E10000 hang created by control board going into a continuous reset mode. | Sun Enterprise 10000 |
| 501-4345-05 | E10000 hang created by control board going into a continuous reset mode. | Sun Enterprise 10000 |
| 501-4347-09 | Early life failures on the E10000 system board could cause system to crash. | Sun Enterprise 10000 |
| 501-4349 | Installation of certain SBus cards in slot 1 of E10000 having older I/O Mezzanine Boards has been found to cause unpredictable behavior, including resets, offlines, and undetected data corruption. | I/O Sun Enterprise 10000 |
| 501-4351 | E10000 Memory Board | Memory Sun Enterprise 10000 |
| 501-4363 | Configuring 336 MHz CPU modules into a Enterprise 10000 system. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4365 | Fan Tray Centerplane | Sun Enterprise 10000 |
| 501-4373 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 501-4375 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-4478 | SBus I/O Board | I/O Sun Enterprise 10000 |
| 501-4776 | E10000 Memory Board | Memory Sun Enterprise 10000 |
| 501-4777 | PCI I/O Riser Board (3.3V) PCI I/O Riser Board (5V) | I/O Sun Enterprise 10000 |
| 501-4778 | PCI I/O FRU Assembly 500-5126 3.3V Riser Kit 565-1474 | I/O Sun Enterprise 10000 |
| 501-4786-01 | Early life failures on the E10000 system board could cause system to crash. | Sun Enterprise 10000 |
| 501-4830 | PCI I/O Board | I/O Sun Enterprise 10000 |
| 501-4836 | 250MHz UltraSPARC II Module (4MB Cache Blackbird) SRAM 100-5528 | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-4837 | Quad Ethernet (QEC/S) Quad FastEthernet 1.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-4837-02 | The installation of the QFE Sbus Card (X1049A) on an E10000 domain running Solaris 2.5.1 or 2.6HW2 will require 'special instructions' to successfully complete the installation. These instructions are unnecessary if the Enterprise 10000 is running Solaris 2.6 HW3/98 or later. | Sun Enterprise 10000 |
| 501-4903-01 | Clarification of patches (patch matrix) needed to operate E10000 system boards. | Sun Enterprise 10000 |
| 501-4995 | 400MHz UltraSPARC II (4MB Cache Sapphire-Black) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 |
| 501-5202 | Configured FC-AL SBus Card 501-2989-04 FC-AL GBIC Optical Module FC-AL SBus Card | Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-5202-03 | Fcode upgrade instructions for the FC100/S Host Adapter supplied with the following luxadm patches can lead to obsolete fcode being installed. 105310 -14 SunOS 5.5.1: Patch for socal, sf driver, and luxadm 105375 -25 SunOS 5.6: sf & socal driver patch 107473 -06 SunOS 5.7: luxadm patch 109529 -03 SunOS 5.8: luxadm, liba5k and libg_fc patch The latest fcode for the FC100/S Host Adapter has been moved to patch 109400 -03 for all versions of Solaris. This change is not reflected in the README files of the luxadm patches currently available ( 105310 , 105375 , 107473 and 109529 ). These patches still provide a lower version of the FC100/S fcode (1.11) and give instructions for installing it. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-5235 | 400MHz UltraSPARC II Module (8MB Cache Sapphire-Black) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-5240-01 | Clarification of patches (patch matrix) needed to operate E10000 system boards. | Sun Enterprise 10000 |
| 501-5266 | Configured FC-AL SBus Card >=501-2989-05 FC-AL GBIC Optical Module FC-AL SBus Board | Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-5266-04 | Fcode upgrade instructions for the FC100/S Host Adapter supplied with the following luxadm patches can lead to obsolete fcode being installed. 105310 -14 SunOS 5.5.1: Patch for socal, sf driver, and luxadm 105375 -25 SunOS 5.6: sf & socal driver patch 107473 -06 SunOS 5.7: luxadm patch 109529 -03 SunOS 5.8: luxadm, liba5k and libg_fc patch The latest fcode for the FC100/S Host Adapter has been moved to patch 109400 -03 for all versions of Solaris. This change is not reflected in the README files of the luxadm patches currently available ( 105310 , 105375 , 107473 and 109529 ). These patches still provide a lower version of the FC100/S fcode (1.11) and give instructions for installing it. | Firmware Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-5425 | 400MHz UltraSPARC II Module (4MB Cache Sapphire-Black) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 |
| 501-5443 | Quad Ethernet (QEC/S) Quad FastEthernet 1.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) Quad FastEthernet 2.0 (QFE/S) RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 501-5524 | PCI adapters in F12K/15K domains may intermittently fail following a reset, reboot or "setkeyswitch on" operation. The failure may prevent the domain from booting or cause a loss of access to devices such as disks or networks. It is also possible for the failure to cause an OS panic. Any panic may potentially cause disk file system corruption. | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V20z Sun Fire V210 Sun Fire V240 Sun Fire V40z Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-5585 | 400MHz UltraSPARC II Module (4MB Cache Sapphire-Black) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 |
| 501-5661 | 400MHz UltraSPARC II Module (8MB Cache Sapphire-Black) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-5693 | E10000 System Board (CIC2) | Sun Enterprise 10000 |
| 501-5727 | PCI adapters in F12K/15K domains may intermittently fail following a reset, reboot or "setkeyswitch on" operation. The failure may prevent the domain from booting or cause a loss of access to devices such as disks or networks. It is also possible for the failure to cause an OS panic. Any panic may potentially cause disk file system corruption. | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3120 Sun StorEdge 3310 Sun StorEdge S1 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 501-5727-03 | Sun Fire 15000 domains with a newly installed Sun Dual Fast Ethernet + Dual SCSI PCI Adapter (X2222A) will not be able to boot Solaris 8 10/01 (U6) unless patch 109885 -08 or higher is applied. As a result, Dstop errors could be encountered which would prevent a Sun Fire 15000 domain from booting. | Sun Enterprise 10000 Sun Fire 12K / 15K |
| 501-5762 | 400MHz UltraSPARC II Module (8MB Cache Sapphire-Black) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-5798 | 464MHz UltraSPARC II Module (8MB Cache Blaze) Sony Espejo Mirrored Data SRAM Sony Mirrored Tag SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-5814 | 400MHz UltraSPARC II Module (8MB Cache Sapphire-Black) IBM Sombra Mirrored Data SRAM IBM Mirrored Tag SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-5815 | 400MHz UltraSPARC II Module (8MB Cache Sapphire-Black) IBM Sombra Mirrored Data SRAM IBM Mirrored Tag SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-5816 | 464MHz UltraSPARC II Module (8MB Cache Blaze) Sony Espejo Mirrored Data SRAM Sony Mirrored Tag SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-5838 | 400MHz UltraSPARC II Module (8MB Cache Sapphire-Black) IBM Sombra Mirrored Data SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-6008 | 400MHz UltraSPARC II Module (8MB Cache Sapphire-Black) IBM Sombra Mirrored Data SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-6009 | 400MHz UltraSPARC II Module (8MB Cache Sapphire-Black) IBM Sombra Mirrored Data SRAM IBM Mirrored Tag SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-6619 | 400MHz UltraSPARC II (8MB Cache Blaze) IBM Sombra Mirrored Data SRAM IBM Mirrored Tag SRAM | Sun Enterprise 10000 |
| 501-6620 | 464MHz UltraSPARC II Module (8MB Cache Blaze) IBM Sombra Mirrored Data SRAM IBM Mirrored Tag SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-6623 | 464MHz UltraSPARC II Module (8MB Cache Blaze) Sony Espejo Mirrored SRAM Sony Mirrored Tag SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 501-6624 | 400MHz UltraSPARC II Module (8MB Cache Blaze) Sony Espejo Mirrored Data SRAM Sony Mirrored Tag SRAM | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 530-2265 | 56-inch Enterprise Expansion Cabinet Assembly Universal Power Sequencer Fan Tray Assembly Fan Tray Rear Cover Top Panel, Medium Grey Side Panel, Medium Grey Keyswitch Assembly Door Assembly AC Power Cord, Harting Han 6HsB to NEMA L6-30P AC Power Cord, Harting Han 6HsB to IEC 309 | Racks Sun Enterprise 10000 Sun Enterprise 5000/6000 Data Center Cabinet Sun SPARCcluster Sun SPARCstorage Array Sun StorEdge A5000 Systems Disk Array Options StorEdge A3000 Rack |
| 530-2265-02 | Ultra Enterprise E5x00 and E6x00 systems, and Delorean 72-inch Rack power cords with pre-tinned wires violates UL 1950 standard. | Sun Enterprise 10000 Sun Enterprise 5500 Sun Enterprise 6500 |
| 530-2266 | 56-inch Enterprise Expansion Cabinet Assembly Universal Power Sequencer Fan Tray Assembly Fan Tray Rear Cover Top Panel, Medium Grey Side Panel, Medium Grey Keyswitch Assembly Door Assembly AC Power Cord, Harting Han 6HsB to NEMA L6-30P AC Power Cord, Harting Han 6HsB to IEC 309 | Racks Sun Enterprise 10000 Sun Enterprise 5000/6000 Data Center Cabinet Sun SPARCcluster Sun SPARCstorage Array Sun StorEdge A5000 Systems Disk Array Options StorEdge A3000 Rack |
| 530-2266-02 | Ultra Enterprise E5x00 and E6x00 systems, and Delorean 72-inch Rack power cords with pre-tinned wires violates UL 1950 standard. | Sun Enterprise 10000 Sun Enterprise 5500 Sun Enterprise 6500 |
| 530-2379 | NEMA L6-30P to Y IEC 320 C19, 20', Option 3850 (obsolete) | Sun Enterprise 10000 |
| 530-2379-01 | Existing power cord for US E10000 systems is too long to meet UL requirements. | Sun Enterprise 10000 |
| 530-2380 | Blue 32A IEC 309 to Y IEC 320 C19, Option 3851 (obsolete) | Sun Enterprise 10000 |
| 530-2380-01 | E10K power cords with pre-tinned wires violates UL 1950 standard | Sun Enterprise 10000 |
| 530-2391 | 48Vdc Front Power Shelf to Rear Power Shelf Cable, .3M | Sun Enterprise 10000 |
| 530-2392 | 48Vdc Cardcage to Power Shelf Cable, 610 mm | Sun Enterprise 10000 |
| 530-2393 | 48Vdc Cardcage to Power Shelf Cable, 1270 mm | Sun Enterprise 10000 Sun SPARCcluster |
| 530-2394 | Cardcage Sense Cable, .9M | Sun Enterprise 10000 |
| 530-2395 | Cardcage Sense Cable, 1.3M | Sun Enterprise 10000 |
| 530-2396 | Centerplane and Upper Fan Power Cable | Sun Enterprise 10000 |
| 530-2397 | Fan Signal Ribbon Cable | Sun Enterprise 10000 |
| 530-2398 | Fan Sense Ribbon Cable | Sun Enterprise 10000 |
| 530-2399 | Lower Fan Power Cable | Sun Enterprise 10000 |
| 530-2400 | Control Board to Remote Power Control Cable, 3M | Sun Enterprise 10000 |
| 530-2401 | Control Board to Remote Power Control Cable, 1.5M | Sun Enterprise 10000 |
| 530-2402 | AC Sequencer to Remote Power Control Cable, .5M | Sun Enterprise 10000 |
| 530-2403 | AC Sequencer to Remote Power Control Cable, 6M | Sun Enterprise 10000 |
| 530-2475 | Internal Power Shelf Circuit Breaker Cable | Sun Enterprise 10000 |
| 530-2476 | Internal Power Shelf Cable, 305 mm | Sun Enterprise 10000 |
| 530-2477 | Internal Power Shelf Cable, 660 mm | Sun Enterprise 10000 |
| 530-2503 | NEMA L6-30P to Y IEC 320 C19, 14.75' Option 3865 (obsolete) | Sun Enterprise 10000 |
| 530-2503-01 | E10K power cords with pre-tinned wires violates UL 1950 standard | Sun Enterprise 10000 |
| 530-2567 | AC Power Cord, Harting Han 6HsB to NEMA L6-30P | Racks Sun Enterprise 10000 |
| 530-2567-02 | Ultra Enterprise E5x00 and E6x00 systems, and Delorean 72-inch Rack power cords with pre-tinned wires violates UL 1950 standard. | Sun Enterprise 10000 Sun Enterprise 5500 Sun Enterprise 6500 |
| 530-2568 | Blue 32A IEC 309 to Han 6HsB, 4.0M (obsolete) | Racks Sun Enterprise 10000 |
| 530-2568-02 | Ultra Enterprise E5x00 and E6x00 systems, and Delorean 72-inch Rack power cords with pre-tinned wires violates UL 1950 standard. | Sun Enterprise 10000 Sun Enterprise 5500 Sun Enterprise 6500 |
| 530-2674-01 | Ultra Enterprise E5x00 and E6x00 systems, and Delorean 72-inch Rack power cords with pre-tinned wires violates UL 1950 standard. | Sun Enterprise 10000 Sun Enterprise 5500 Sun Enterprise 6500 |
| 530-2675-01 | Ultra Enterprise E5x00 and E6x00 systems, and Delorean 72-inch Rack power cords with pre-tinned wires violates UL 1950 standard. | Sun Enterprise 10000 Sun Enterprise 5500 Sun Enterprise 6500 |
| 530-2802 | Dual Power Option 48Vdc Cable | Sun Enterprise 10000 |
| 530-2880 | Dual Power Option Status Module I/O Cable | Sun Enterprise 10000 |
| 530-2993 | AC Y Power Cord, NEMA L6-30P, 14.75', Option 3865 | Sun Enterprise 10000 |
| 530-2994 | Blue 32A IEC 309 to Y IEC 320 C19, 20', Option 3851 | Sun Enterprise 10000 |
| 540-2989 | Configured FC-AL SBus Card >=501-2989-05 FC-AL GBIC Optical Module FC-AL SBus Board | Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 540-3024 | Ultra 1, Ultra 2 Ultra 30, Ultra 60, Ultra 80 E250, E450, E220R, E420R Sun Blade 1000 E150, nfs 150, i 150 MultiPack, E3000, E3500 A1000, D1000, A3500 A5000, A5100, A5200, A7000 Netra ct 400, Netra ct 800 st D130, st A1000, st D1000 | Disk (external) Disk (internal) Disk Spud Bracket Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire E2900 Sun Fire E2900, RoHS:YL Sun Fire V120 Sun Fire V125 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V250 Server Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 120 Sun Netra 1280 Server Sun Netra 1280 Server, RoHS:YL Sun Netra 1290, RoHS:YL Sun Netra 20 Sun Netra 240 Server Sun Netra 240 Server, RoHS:YL Sun Netra 440 Server Sun Netra 440 Server, RoHS:YL Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun StorEdge S1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 T3 |
| 540-3059 | Processor Cabinet | Sun Enterprise 10000 |
| 540-3060 | Rear AC/DC Power Shelf (SYS 0-7, FAN 0-1) Front AC/DC Power Shelf (SYS 8-15, FAN 2-3) | Sun Enterprise 10000 |
| 540-3062 | AC Input Module | Sun Enterprise 10000 |
| 540-3063 | System Board Filler Panel | Sun Enterprise 10000 |
| 540-3064 | Control Board Filler Panel | Sun Enterprise 10000 |
| 540-3065 | Fan Tray Fan Tray (Option 9671) Fan Tray Filler Panel | Sun Enterprise 10000 |
| 540-3066 | Circuit Breaker (×11 on each side) | Sun Enterprise 10000 |
| 540-3067 | Remote Power Control Module | Sun Enterprise 10000 |
| 540-3068 | Remote Power Control Module Shelf | Sun Enterprise 10000 |
| 540-3069 | Rear AC/DC Power Shelf (SYS 0-7, FAN 0-1) Front AC/DC Power Shelf (SYS 8-15, FAN 2-3) | Sun Enterprise 10000 |
| 540-3075 | Fan Tray Fan Tray (Option 9671) Fan Tray Filler Panel | Sun Enterprise 10000 |
| 540-3409 | Fan Tray Fan Tray (Option 9671) Fan Tray Filler Panel | Sun Enterprise 10000 |
| 540-3426 | Remote Power Control Module | Sun Enterprise 10000 |
| 540-3440 | Remote Power Control Module | Sun Enterprise 10000 |
| 540-3441 | AC Input Module | Sun Enterprise 10000 |
| 540-3542 | Right Front/Rear Door Front/Rear Door Foam Air Filter | Sun Enterprise 10000 |
| 540-3543 | Left Front/Rear Door | Sun Enterprise 10000 |
| 540-3564 | n/a | Sun Enterprise 10000 |
| 540-4178 | Empty 1.0" Disk Drive Slot Filler 9.1GB 10000 RPM Disk Drive FRU, NEBS Level 3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 T3 |
| 540-4305 | 390-0002 [F] | Sun Enterprise 10000 |
| 540-4372 | StorEdge Network FC Switch-8 and StorEdge Network FC Switch-16 products installed in a Storage Area Network (SAN) configuration must have the proper level of firmware installed for proper operation. All switches in the SAN must contain matching firmware versions. Failure to verify and install the correct switch firmware when installing or replacing switches in a SAN can cause the switch to fail. It is important that the firmware of existing switches in a SAN and any replacement switch be checked for compatibility when installing a new switch into the SAN configuration. | Fibre Channel Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire V1280 Sun Netra 1280 Server Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3511 FC Array Sun StorEdge 3900/6900 Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Sun StorEdge L5500 Sun StorEdge L8500 Tape Library Switches T3 |
| 540-4387 | Dual Power Option Status Module | Sun Enterprise 10000 |
| 540-4508 | AC Input Module | Sun Enterprise 10000 |
| 540-4520 | Empty 1.0" Disk Drive Slot Filler 9.1GB 10000 RPM Disk Drive FRU, NEBS Level 3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Fire V120 Sun Netra 120 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Systems Telco Netra ct 400 Systems Telco Netra ct 800 T3 |
| 555-1897 | Card Cage Air Filter Card Cage Air Filter Kit with 8× 370-2845 | Sun Enterprise 10000 |
| 555-1897-01 | New guidelines have been introduced for air filter maintenance on E10000 systems. | Sun Enterprise 10000 |
| 560-2517-01 | SBus bracket kit may be needed when installing SBus cards in Enterprise 10000 systems. | Sun Enterprise 10000 |
| 565-1404-01 | SBus bracket kit may be needed when installing SBus cards in Enterprise 10000 systems. | Sun Enterprise 10000 |
| 565-1673 | E10000 SBus Bracket Kit (240-1821 + 330-1265 + 340-2348) | Sun Enterprise 10000 |
| 565-1673-01 | SBus bracket kit may be needed when installing SBus cards in Enterprise 10000 systems. | Sun Enterprise 10000 |
| 594-2466 | 375-3383 [F] | Sun Enterprise 10000 |
| 595-2724 | 501-2981 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 595-2731 | 501-1869 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 595-3213 | 501-2069 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 595-3257 | 370-1704 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge L1000 Sun StorEdge L20 / L40 / L60 Sun StorEdge L3500 Sun StorEdge L9 Sun Ultra 2 |
| 595-3258 | 370-1703 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge L9 Sun StorEdge S1 Sun Ultra 2 |
| 595-3869 | 501-2653 [F] (32MB) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 595-3870 | 501-2654 [F] (128MB) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 595-4187 | 370-2443 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L9 Sun Ultra 2 |
| 595-4303 | 540-2989 501-5266 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 595-4343 | 501-4178 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 595-4344 | 370-2868 [F] | Sun Enterprise 10000 |
| 595-4410 | 501-4836 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 595-4624 | 540-3441 [F] | Sun Enterprise 10000 |
| 595-4625 | 501-4776 [F] | Sun Enterprise 10000 |
| 595-4627 | 540-3440 [F] | Sun Enterprise 10000 |
| 595-4628 | 300-1430 [F] | Sun Enterprise 10000 |
| 595-4945 | 370-3795 [F] | Sun Enterprise 10000 |
| 595-4949 | E10000 SSP (Enterprise 250) | Sun Enterprise 10000 |
| 595-5036 | 501-1931 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 595-5065 | 501-5585 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 |
| 595-5120 | UniPack Mounting Tray Option X9645A | Sun Enterprise 10000 |
| 595-5205 | 501-5494 [F] | Sun Enterprise 10000 |
| 595-5250 | E10000 SSP (Ultra 5) | Sun Enterprise 10000 |
| 595-5624 | 501-5727 [F] | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge S1 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-5773 | 501-5524 [F] | Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 595-5816 | Current switch replacement procedures for the 39x0 & 69x0 are incorrect. | Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra 20 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| 595-5830 | 375-3019 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun Ultra 60 Sun Ultra 80 |
| 595-5853 | 375-3030 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun Ultra 60 Sun Ultra 80 T3 |
| 595-5904 | E10000 SSP (Netra T1) | Sun Enterprise 10000 |
| 595-5943 | 375-3048 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3900/6900 Sun StorEdge L5500 |
| 595-6425 | 375-3102 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun StorEdge 3900/6900 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun Ultra 60 Sun Ultra 80 T3 |
| 595-6426 | 375-3108 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun StorEdge 3900/6900 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun Ultra 60 Sun Ultra 80 T3 |
| 596-2148 | 501-4478 [F] | Sun Enterprise 10000 |
| 596-2294 | 501-4830 [F] | Sun Enterprise 10000 |
| 596-2325 | 501-4363 [F] | Sun Enterprise 10000 |
| 596-2453 | 300-1403 [F] | Sun Enterprise 10000 |
| 596-2556 | 501-5838 [F] | Sun Enterprise 10000 |
| 596-2567 | 501-5838 [F] | Sun Enterprise 10000 |
| 596-2984 | StorEdge D1000 12-Slot Rackmount 72GB (4 × 18.2GB) 10000 RPM | Sun Enterprise 10000 |
| 596-2985 | StorEdge D1000 12-Slot Rackmount 145GB (4 × 36.4GB) 10000 RPM | Sun Enterprise 10000 |
| 596-2986 | StorEdge D1000 12-Slot Rackmount 218GB (12 × 18.2GB) 10000 RPM | Sun Enterprise 10000 |
| 596-2987 | StorEdge D1000 12-Slot Rackmount 436GB (12 × 36.4GB) 10000 RPM | Sun Enterprise 10000 |
| 596-3110 | 501-5798 [F] | Sun Enterprise 10000 |
| 599-2326 | 18.2GB 7200 RPM Disk UniPack 18.2GB 10000 RPM Disk UniPack 36.4GB 10000 RPM Disk UniPack | Disk (external) Sun Enterprise 10000 |
| 600-5471 | E10000 SSP (Ultra 5) | Sun Enterprise 10000 |
| 600-5931 | E10000 SSP (Ultra 5+) | Sun Enterprise 10000 |
| 600-6466 | E10000 SSP (Ultra 5+) | Sun Enterprise 10000 |
| 600-7415 | E10000 SSP (Enterprise 250) | Sun Enterprise 10000 |
| 602-2438 | E10000 SSP (Sun Fire V120) | Sun Enterprise 10000 |
| 603-2997 | E10000 SSP (SPARCstation 5) | Sun Enterprise 10000 |
| 605-1319 | 501-2603 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1535 | 501-2919 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1568 | 501-2739 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge S1 Sun Ultra 2 |
| 605-1591 | 375-0002 [F] | Sun Enterprise 10000 Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 |
| 605-1592 | 375-0003 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 605-1597 | 501-5443 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1601 | 501-4373 [F] | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 605-1602 | 501-4375 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 4800 Sun Fire 6800 Sun Ultra 2 |
| 605-1609 | FDDI/S DAS 5.0 HW/SW Assembly FDDI/S DAS 6.0 HW/SW Assembly Network Peripherals FDDI/S DAS Fiber Card (obs) Network Peripherals FDDI/S DAS Fiber Card 3 Meter FDDI Cable, Type SC to MIC (obs) Cable Assembly MIC to MIC Coupler 3 Meter FDDI Cable, SC Duplex to MIC | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1610 | FDDI/S SAS 5.0 HW/SW Assembly FDDI/S SAS 6.0 HW/SW Assembly Network Peripherals FDDI/S SAS Fiber Card (obs) Network Peripherals FDDI/S SAS Fiber Card Cable Assembly MIC to MIC Coupler 3 Meter FDDI Cable, SC Duplex to MIC | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1612 | 501-1725 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1616 | 501-1932 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1620 | 501-2794 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1621 | 501-2795 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1622 | 501-2864 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| 605-1623 | 501-3028 [F] | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 605-1624 | 501-3027 [F] | Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 605-1625 | 501-3029 [F] | Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 605-1631 | 370-3878 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 605-1636 | 370-3878 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 4800 Sun Fire 6800 |
| 605-1645 | 501-1932 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| 605-1649 | 370-4273 [F] | Sun Enterprise 10000 |
| X1012A | 501-2603 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1018A | On some Ultra 1 and Ultra 2 systems with Fast/Wide single-ended SCSI buses consisting of external devices and 2GB-7200 rpm disk drives, users have reported SCSI write parity errors. The condition is seen most often when there are internal 2GB-7200 rpm disk drives and MultiPack-12 (2GB) enclosures are on the same SCSI bus. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3120 Sun StorEdge 3310 Sun StorEdge S1 Sun Ultra 2 |
| X1044A | 375-0002 [F] | Sun Enterprise 10000 Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 |
| X1045A | 375-0003 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X1049A | QFE Sbus Card (501-4837-02) | Allgemein / Unbekannt Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1052A | 501-1902 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1053A | 501-2981 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1057A | 501-2069 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1058A | QEC SBus Card (501-2062) | Allgemein / Unbekannt Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1059A | 501-2919 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1062A | 370-1704 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge L1000 Sun StorEdge L20 / L40 / L60 Sun StorEdge L3500 Sun StorEdge L9 Sun Ultra 2 |
| X1063A | On some Ultra 1 and Ultra 2 systems with Fast/Wide single-ended SCSI buses consisting of external devices and 2GB-7200 rpm disk drives, users have reported SCSI write parity errors. The condition is seen most often when there are internal 2GB-7200 rpm disk drives and MultiPack-12 (2GB) enclosures are on the same SCSI bus. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge L9 Sun StorEdge S1 Sun Ultra 2 |
| X1065A | 370-2443 [F] | SCSI Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun Ultra 2 |
| X1070A | 370-3878 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X1071A | 370-3878 [F] | Communication Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 4800 Sun Fire 6800 |
| X1073A | 595-4344 | Sun Enterprise 10000 |
| X1080A | 370-4273 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X1140A | 501-4375 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1141A | Adapter boards capable of 66MHz operation may only run at 33MHz when installed into 66MHz PCI I/O slots on Sun Fire 12K/15K platforms. | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X1142A | 370-3142 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1143A | 370-3143 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1144A | 501-1932 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1145A | 501-1725 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1146A | 501-1931 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1147A | 501-2794 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1148A | 501-2795 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1149A | 501-2864 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 |
| X1151A | PCI adapters in F12K/15K domains may intermittently fail following a reset, reboot or "setkeyswitch on" operation. The failure may prevent the domain from booting or cause a loss of access to devices such as disks or networks. It is also possible for the failure to cause an OS panic. Any panic may potentially cause disk file system corruption. | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1157A | 501-3028 [F] | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1158A | 501-3027 [F] | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1159A | 501-3029 [F] | Communication Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X2144A | 501-1932 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X2222A | PCI adapters in F12K/15K domains may intermittently fail following a reset, reboot or "setkeyswitch on" operation. The failure may prevent the domain from booting or cause a loss of access to devices such as disks or networks. It is also possible for the failure to cause an OS panic. Any panic may potentially cause disk file system corruption. | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3120 Sun StorEdge 3310 Sun StorEdge S1 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X2530A | 501-4178 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X2550A | 501-4836 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X2560A | 501-4363 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X2570A | 501-4995 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 |
| X2580A | 501-5235 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X2590A | 501-6620 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X2721A | 595-4945 | Sun Enterprise 10000 |
| X2722A | 595-5205 | Sun Enterprise 10000 |
| X2750A | 603-2997 | Sun Enterprise 10000 |
| X2751A | 600-5471 | Sun Enterprise 10000 |
| X2753A | 600-5931 | Sun Enterprise 10000 |
| X2754A | 595-5250 | Sun Enterprise 10000 |
| X2755A | 595-4949 | Sun Enterprise 10000 |
| X2757A | 595-5904 | Sun Enterprise 10000 |
| X2760A | An SSP power patch is required to operate E10000 2760A/2761A system boards. | Sun Enterprise 10000 |
| X2761A | After installing SF+ system boards in an E10000 system, domains may not reboot. | Sun Enterprise 10000 |
| X3151A | 501-5524 [F] | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V20z Sun Fire V210 Sun Fire V240 Sun Fire V40z Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X3875A | 595-4624 | Sun Enterprise 10000 |
| X6727A | Origin: On X6727A (375-3030) Card - P3 to J3(TX); P4 to J4(RX) Destination: On Expansion Backplane - C to J01100, D to J01101 | Allgemein / Unbekannt Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| X6730A | 595-4303 | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| X6731A | This FIN is to inform the field of a new style GBIC that will be shipping with A5X00 Storage Arrays. Installing a FINISAR GBIC in any platform other than A5X00 will result in a restricted access condition which may result in unanticipated downtime. | Disk (external) Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 Sun Ultra 2 T3 |
| X6746A | 595-5358 595-5560 180-1932 540-4189 540-4372 340-5773 370-4035 | Fibre Channel Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire V1280 Sun Netra 1280 Server Sun Netra 20 Sun StorEdge 3900/6900 Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Sun StorEdge L5500 Sun StorEdge L8500 Tape Library Switches T3 |
| X6757A | A potential for data loss exists with SBus Fibre Channel Adapters (6757A) attached to Sun StorEdge 99xx arrays or to Fibre Channel Tape drives in specific configurations. | Allgemein / Unbekannt Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 9910/9960 Sun StorEdge 9970/9980 Array Field Information Notices Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge L5500 |
| X6767A | 375-3102 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| X6768A | 375-3108 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| X6799A | 375-3019 15 [C] | Fibre Channel Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| X7022A | 256 MB (8 × 32MB DIMMs) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X7023A | 1 GB (8 × 128MB DIMMs) | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 |
| X7025A | 595-4625 | Sun Enterprise 10000 |
| X9645A | 595-5120 | Sun Enterprise 10000 |
| X9681A | 595-4627 | Sun Enterprise 10000 |
| X9685A | 595-4628 | Sun Enterprise 10000 |