Parts for System: Sun Fire 3800
| Part Number | Description | Associated Systems |
|---|---|---|
| 180-1943 | Upper Power Cord, NEMA L6-30P to Han 6HsB, Upper Power Cord, Blue 32A IEC 309 to Han 6HsB, Lower Power Cord, NEMA L6-30P to Han 6HsB, Lower Power Cord, Blue 32A IEC 309 to Han 6HsB, Upper Power Cord, Blue 30A Watertight IEC 309 to Han 6HsB, Upper Power Cord, Blue 32A Watertight IEC 309 to Han 6HsB, Lower Power Cord, Blue 30A Watertight IEC 309 to Han 6HsB, Lower Power Cord, Blue 32A Watertight IEC 309 to Han 6HsB, | Racks Sun Enterprise 5000/6000 Data Center Cabinet Sun Fire 12K / 15K Sun Fire 15K Sun Fire 3800 Sun Fire 6800 Sun Fire E20K Sun Fire E20K, RoHS:YL Sun Fire E25K Sun Fire E6900 Sun Fire E6900, RoHS:YL |
| 180-1944 | Upper Power Cord, NEMA L6-30P to Han 6HsB, Upper Power Cord, Blue 32A IEC 309 to Han 6HsB, Lower Power Cord, NEMA L6-30P to Han 6HsB, Lower Power Cord, Blue 32A IEC 309 to Han 6HsB, Upper Power Cord, Blue 30A Watertight IEC 309 to Han 6HsB, Upper Power Cord, Blue 32A Watertight IEC 309 to Han 6HsB, Lower Power Cord, Blue 30A Watertight IEC 309 to Han 6HsB, Lower Power Cord, Blue 32A Watertight IEC 309 to Han 6HsB, | Racks Sun Enterprise 5000/6000 Data Center Cabinet Sun Fire 12K / 15K Sun Fire 15K Sun Fire 3800 Sun Fire 6800 Sun Fire E20K Sun Fire E20K, RoHS:YL Sun Fire E25K Sun Fire E6900 Sun Fire E6900, RoHS:YL |
| 180-1949 | Network 2GB FC Switch-8 AC Y Power Cord (Option X319YA) Mounting Tray Right Mounting Rail (replaced by 565-1735) Left Mounting Rail (replaced by 565-1735) Tray Adapter Bracket Rear Bracket 2U Vented Panel Switch Assembly/FRU Hub Retainer 8-Port Switch Rack Mount Kit | Fibre Channel Sun Fire 3800 Sun StorEdge 6320 System Sun StorEdge 6920 Switches |
| 180-2164 | IEC 320 C13 to NEMA 6-15P, 10A/250V, 2.0M, Black, Option X320A, 1 | Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire T2000 Sun Fire V125 Sun Fire V210 Sun Fire V215 Server, RoHS:YL Sun Fire V240 Sun Fire V245 Sun Fire V445 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun SPARC Enterprise M3000 Server Sun SPARC Enterprise T2000 Sun SPARC Enterprise T5240 Server Sun SPARC Enterprise T5440 Server Sun StorEdge A3500 Sun Storage 7210 Sun StorageTek 5220 NAS, RoHS:YL Sun StorageTek 5320 NAS Sun StorageTek 5320 NAS, RoHS:YL |
| 300-1441 | A145, AC-48VDC Power Supply | Power Supplies Sun Fire 3800 |
| 300-1529 | A145E, AC-48VDC Power Supply | Power Supplies Sun Fire 3800 |
| 330-2014 | Keyswitch Assembly/FRU LED Board to Backplane Cable Fan LED Board Keyswitch Cable Assembly Key (replaced 330-1651) | Racks Sun Enterprise 3000 Sun Enterprise 3500 Sun Enterprise 4000 Sun Enterprise 4500 Sun Enterprise 5000 Sun Enterprise 5000/6000 Data Center Cabinet Sun Enterprise 5500 Sun Enterprise 6000 Sun Enterprise 6500 Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun SPARC(R) Systems that have interlock switch feature. |
| 330-2821 | Sun Fire 3800/4800/4810/6800/E4900/E6900 System Board Filler Panel | Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire 6800 Sun Fire E4900 Sun Fire E6900 |
| 330-3155 | I/O Assembly Filler Panel (install when servicing) | Sun Fire 3800 |
| 340-5890 | Chassis Assembly Main Chassis Sub Chassis Lower Chassis Bulkhead LED Assembly | Sun Fire 3800 |
| 340-5896 | Chassis Assembly Main Chassis Sub Chassis Lower Chassis Bulkhead LED Assembly | Sun Fire 3800 |
| 340-6168 | Chassis Assembly Main Chassis Sub Chassis Lower Chassis Bulkhead LED Assembly | Sun Fire 3800 |
| 340-6728 | Cabinet Extension Option 4347 Kickplate Extension Right Extension Left Extension Top Extension | Racks Sun Fire 3800 |
| 370-0118-02 | cPCI Dual FC Network Adapter ( 375-0118-02) FRU cPCI Dual FC Network Adapter (F375-0118-02) | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 375-0118 | Compact PCI (cPCI) Dual Channel FC | Fibre Channel Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| 375-0118-02 | Sun Fire x800 systems are subject to a "panic" problem at boot time when a cPCI Dual FC Network Adapter (FRU or X-option) is installed for the first time. If a customer installs this board and boots the system, they will see panic messages on the console and the boot will fail. However, any subsequent reboots will be successful. This may result in an unnecessary service call. This cPCI board (P/N 370-0118-02) has been shipped with Sun Fire X800 systems and as an X-option. The current estimate is that less than 1000 boards have been installed in systems and 1200 boards are in field stock (FRUs and x-options) as of 7/12/01. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 375-0119 | Dual Differential Ultra SCSI, cPCI (Use for DLT8000) | SCSI Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge A1000 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 |
| 501-4143-15 | If the Emulex FC HBA card is placed on the same PCI Bus with any other PCI card which causes the Schizo chip to attempt a 64-bit PIO, a system panic would most likely result. The problem will not occur if the Emulex HBA card is installed alone on a PCI Bus. UltraSparc-III platforms utilizing the Schizo 2.1 or 2.2 ASIC may experience panics due to address parity errors on the PCI Bus. The problem has been seen on the Sun Fire 280R with the Emulex FC HBA card in combination with a PGX32 card installed on the same PCI Bus. This condition occurs when a card on the PCI Bus detects a 64-bit parity address error on the PCI Bus while another card on the same PCI Bus is performing a 64-bit PIO. The following error messages are displayed prior to a system panic: WARNING: pcisch-0: PCI fault log start: PCI SERR PCI error occurred on device #6 dwordmask=0 bytemask=0 PCI primary error (0): pcisch-0: PCI secondary error (0): pcisch-0: PBM AFAR 0.00000000: pcisch-0: PCI config space error status (4280): signaled system error. pcisch-0: PCI fault log end. panic[cpu1]/thread=2a10000bd40: pcisch-0: PCI bus 2 error(s)! | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V880 Sun Netra 20 |
| 501-5030 | 256MB DIMM 3.3V ECC / 7ns SDRAM Option 7053 not supported on V490 or V890 | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 |
| 501-5401 | 1 GB (4 × 256MB SDRAM DIMMs) | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 501-5407-13 | Some Sun Fire 3800/4800/4810/6800 systems with redundant System Controllers (SC) may experience failed domains when clock failover does not occur after a clock failure. This occurs when the System Controller has an incorrect clock source selection which causes the clock failover feature to be disabled, leading to a system malfunction. If a clock fails and there is a redundant SC, the domains using the failed clock will not switch over to the redundant clock and will hang. Systems at risk are those with two SC's shipped prior to July 2001, or those where a second SC board has been added from FRU stock shipped prior to July 2001. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 501-5465 | 2 Slot Centerplane (Factory Installed) | Sun Fire 3800 |
| 501-5465-04 | Certain Sun Fire 3800 systems with duplicate MAC addresses running on common subnets may experience network issues. | Sun Fire 3800 |
| 501-5483 | Compact PCI (cPCI) SunATM 155 MMF NIC | Communication Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 501-5502 | Compact PCI (cPCI) QuadFastEthernet (QFE) | Ethernet Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 501-5523 | Compact PCI (cPCI) Gigabit Ethernet * | Ethernet Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 501-5531 | 540-4591 | Sun Fire 3800 |
| 501-5563 | System Controller Board | Firmware Sun Fire 3800 |
| 501-5563-12 | Some Sun Fire 3800/4800/4810/6800 systems with redundant System Controllers (SC) may experience failed domains when clock failover does not occur after a clock failure. This occurs when the System Controller has an incorrect clock source selection which causes the clock failover feature to be disabled, leading to a system malfunction. If a clock fails and there is a redundant SC, the domains using the failed clock will not switch over to the redundant clock and will hang. Systems at risk are those with two SC's shipped prior to July 2001, or those where a second SC board has been added from FRU stock shipped prior to July 2001. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 501-5564 | Compact PCI (cPCI) SunATM 622 MMF NIC | Communication Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 501-5569 | Chassis Assembly Main Chassis Sub Chassis Lower Chassis Bulkhead LED Assembly | Sun Fire 3800 |
| 501-5570 | VHDCI-68 Cables 530-2452-02 05/01 530-2453-02 05/99 530-2454-02 05/01 530-2455-02 05/01 530-2538-01 10/01 530-2982-01 10/01 530-2984-01 10/01 530-2985-01 10/01 | SCSI Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge S1 |
| 501-5570-06 | Sun Fire 3800 systems with cPCI cards installed will initially PANIC. Then, upon reboot, system will run fine for some period of time, but PANICs could happen more often, requiring more frequent re-boots. | Sun Fire 3800 |
| 501-5818-06 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 501-5876 | 2 Slot Centerplane (Factory Installed) | Sun Fire 3800 |
| 501-5876-01 | Certain Sun Fire 3800 systems with duplicate MAC addresses running on common subnets may experience network issues. | Sun Fire 3800 |
| 501-5938-07 | If the Emulex FC HBA card is placed on the same PCI Bus with any other PCI card which causes the Schizo chip to attempt a 64-bit PIO, a system panic would most likely result. The problem will not occur if the Emulex HBA card is installed alone on a PCI Bus. UltraSparc-III platforms utilizing the Schizo 2.1 or 2.2 ASIC may experience panics due to address parity errors on the PCI Bus. The problem has been seen on the Sun Fire 280R with the Emulex FC HBA card in combination with a PGX32 card installed on the same PCI Bus. This condition occurs when a card on the PCI Bus detects a 64-bit parity address error on the PCI Bus while another card on the same PCI Bus is performing a 64-bit PIO. The following error messages are displayed prior to a system panic: WARNING: pcisch-0: PCI fault log start: PCI SERR PCI error occurred on device #6 dwordmask=0 bytemask=0 PCI primary error (0): pcisch-0: PCI secondary error (0): pcisch-0: PBM AFAR 0.00000000: pcisch-0: PCI config space error status (4280): signaled system error. pcisch-0: PCI fault log end. panic[cpu1]/thread=2a10000bd40: pcisch-0: PCI bus 2 error(s)! | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V880 Sun Netra 20 |
| 501-6109 | 1GB DIMM 501-6109 1GB DIMM 501-7386 3.3V ECC / 7ns SDRAM Option 7056 Not supported at 750MHz | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 |
| 501-6242 | 2GB SDRAM DIMM, L | Memory Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V890 |
| 501-7385 | 256MB DIMM 3.3V ECC / 7ns SDRAM Option 7053 not supported on V490 or V890 | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 |
| 501-7386 | 1GB DIMM 501-6109 1GB DIMM 501-7386 3.3V ECC / 7ns SDRAM Option 7056 Not supported at 750MHz | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 |
| 530-1351 | 56" Rack Mounting Kit, Option X965A M6 1.0 × 10 mm Screw (×4) Chassis Mounting Bracket Rack Mounting Bracket, Left #10-32 × 1/2" Screw (×12) Rack Mounting Bracket, Right Blower Option X966A Blower (not included with Option 965) IEC 320 - Reverse IEC 320 Power Cord, 240V IEC-320-c13 to NEMA 6-15p, Power Cord 10A/250V, 2M | Disk (external) SPARCstation 10 Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire V125 Sun Fire V210 Sun Fire V215 Server, RoHS:YL Sun Fire V240 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun SPARCcluster Sun SPARCstorage Array Sun StorEdge A3500 Sun StorageTek 5320 NAS Sun StorageTek 5320 NAS, RoHS:YL Sun-4 Architecture (Generic) Systems Disk Array Options RSM Array 2000 / StorEdge A3000 |
| 530-1869 | Serial Port Adapter (Y-Splitter) Cable, 50 cm | Cables Data Cables by Type Cables External Data Cables by Type Sun Enterprise 450 Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire E4900 Sun Fire V880 Sun Fire V890 Sun-4m Architecture |
| 540-4040 | CPU/Memory Board Filler Board | Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire 6800 Sun Fire E4900 Sun Fire E6900 |
| 540-4190 | Chassis Assembly Main Chassis Sub Chassis Lower Chassis Bulkhead LED Assembly | Sun Fire 3800 |
| 540-4193 | Fan Tray | Sun Fire 3800 |
| 540-4246 | Power Supply Filler Panel | Sun Fire 3800 |
| 540-4347 | Fan Tray Filler Panel | Sun Fire 3800 |
| 540-4446 | Sun Fire Link Switch Option X4170A Sun Fire Link Switch Option 4170A AC Power Cord cPCI Filler Panel Tested Switch Assembly System Controller WCIX Module Switch Assembly 150W Power Supply Fan Tray Switch Chassis Assembly Chassis Backplane + AC Harness + AC Module | Sun Fire 3800 Sun Fire 6800 Switches |
| 540-4562 | System Controller Filler Board | Sun Fire 3800 |
| 540-4591 | Compact PCI (cPCI) I/O Assembly (6 slot) | Sun Fire 3800 |
| 540-4591-01 | If the Emulex FC HBA card is placed on the same PCI Bus with any other PCI card which causes the Schizo chip to attempt a 64-bit PIO, a system panic would most likely result. The problem will not occur if the Emulex HBA card is installed alone on a PCI Bus. UltraSparc-III platforms utilizing the Schizo 2.1 or 2.2 ASIC may experience panics due to address parity errors on the PCI Bus. The problem has been seen on the Sun Fire 280R with the Emulex FC HBA card in combination with a PGX32 card installed on the same PCI Bus. This condition occurs when a card on the PCI Bus detects a 64-bit parity address error on the PCI Bus while another card on the same PCI Bus is performing a 64-bit PIO. The following error messages are displayed prior to a system panic: WARNING: pcisch-0: PCI fault log start: PCI SERR PCI error occurred on device #6 dwordmask=0 bytemask=0 PCI primary error (0): pcisch-0: PCI secondary error (0): pcisch-0: PBM AFAR 0.00000000: pcisch-0: PCI config space error status (4280): signaled system error. pcisch-0: PCI fault log end. panic[cpu1]/thread=2a10000bd40: pcisch-0: PCI bus 2 error(s)! | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V880 Sun Netra 20 |
| 540-4591-02 | Sunfire 3800 systems with 540-4591-02 (or lower) cPCI I/O Assemblies will not support Hot Swapping of cPCI cards. | Allgemein / Unbekannt Sun Fire 3800 |
| 540-4613 | Cabinet Assembly Cabinet Subassembly Cabinet Subassembly Cabinet Frame | Racks Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun StorEdge 3120 |
| 540-4616-01 | If the Emulex FC HBA card is placed on the same PCI Bus with any other PCI card which causes the Schizo chip to attempt a 64-bit PIO, a system panic would most likely result. The problem will not occur if the Emulex HBA card is installed alone on a PCI Bus. UltraSparc-III platforms utilizing the Schizo 2.1 or 2.2 ASIC may experience panics due to address parity errors on the PCI Bus. The problem has been seen on the Sun Fire 280R with the Emulex FC HBA card in combination with a PGX32 card installed on the same PCI Bus. This condition occurs when a card on the PCI Bus detects a 64-bit parity address error on the PCI Bus while another card on the same PCI Bus is performing a 64-bit PIO. The following error messages are displayed prior to a system panic: WARNING: pcisch-0: PCI fault log start: PCI SERR PCI error occurred on device #6 dwordmask=0 bytemask=0 PCI primary error (0): pcisch-0: PCI secondary error (0): pcisch-0: PBM AFAR 0.00000000: pcisch-0: PCI config space error status (4280): signaled system error. pcisch-0: PCI fault log end. panic[cpu1]/thread=2a10000bd40: pcisch-0: PCI bus 2 error(s)! | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V880 Sun Netra 20 |
| 540-4617-03 | If the Emulex FC HBA card is placed on the same PCI Bus with any other PCI card which causes the Schizo chip to attempt a 64-bit PIO, a system panic would most likely result. The problem will not occur if the Emulex HBA card is installed alone on a PCI Bus. UltraSparc-III platforms utilizing the Schizo 2.1 or 2.2 ASIC may experience panics due to address parity errors on the PCI Bus. The problem has been seen on the Sun Fire 280R with the Emulex FC HBA card in combination with a PGX32 card installed on the same PCI Bus. This condition occurs when a card on the PCI Bus detects a 64-bit parity address error on the PCI Bus while another card on the same PCI Bus is performing a 64-bit PIO. The following error messages are displayed prior to a system panic: WARNING: pcisch-0: PCI fault log start: PCI SERR PCI error occurred on device #6 dwordmask=0 bytemask=0 PCI primary error (0): pcisch-0: PCI secondary error (0): pcisch-0: PBM AFAR 0.00000000: pcisch-0: PCI config space error status (4280): signaled system error. pcisch-0: PCI fault log end. panic[cpu1]/thread=2a10000bd40: pcisch-0: PCI bus 2 error(s)! | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V880 Sun Netra 20 |
| 540-4674 | Cabinet Extension Option 4347 Kickplate Extension Right Extension Left Extension Top Extension | Racks Sun Fire 3800 |
| 540-4729-04 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-4730-04 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-4857 | Cabinet Extension Option 4347 Kickplate Extension Right Extension Left Extension Top Extension | Racks Sun Fire 3800 |
| 540-4934-03 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-4934-04 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-4984-02 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-4984-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-4990-03 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-4990-04 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-4992-02 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-4992-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-4993-02 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-4993-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5051-02 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-5051-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5051-04 | Sun Fire 3800/4800/4810/6800 with 5.13.3 firmware gives warning message when USIII+ processors are installed on System Boards with Late_Write Ecache DIMMs. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5052-02 | UltraSPARC III based platforms could be susceptible to Correctable Fast ECC (UCC) errors that could cause a system panic resulting in loss of service of the system. Any UltraSPARC III based server running Solaris 8 without PatchId 108528-15 can be affected. Systems running Solaris 9 are not affected, and pre-Solaris 8 is not supported on these platforms. This issue has typically been seen on 900MHz UltraSPARC III based processors, although other UltraSPARC III based processors have been impacted as well. | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-5052-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5084 | 256MB SDRAM DIMM | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-5085 | 512MB SDRAM DIMM, L | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 540-5086 | 4 GB (4 × 1GB SDRAM DIMMs) * | Memory Sun Fire 12K / 15K Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Netra 20 |
| 540-5089-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5094-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5095-03 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5267-01 | Sun Fire 3800/4800/4810/6800 with 5.13.3 firmware gives warning message when USIII+ processors are installed on System Boards with Late_Write Ecache DIMMs. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5267-02 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5268-02 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-5269-02 | Sun Fire 6800/4810/4800/3800 firmware versions 5.11.x and 5.12.x are not compatible with the latest released version of Cheetah processors. The Cheetah 2.3 CPU (900MHz and 1050MHz), as wel as all future CPU releases, will not be recognized when installed into Sun Fire systems with these two earlier versions of firmware. Because of this, customers and field support may need to proactively upgrade Sun Fire system firmware to versions 5.13.2 or above. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 540-6489 | 1GB DIMM 3.3V ECC / 7ns SDRAM Option 7056A-Z L not supported at 750MHz | Memory Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V890 |
| 540-6728 | CPU/Memory Board Filler Board, | Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire 6800 Sun Fire E4900 Sun Fire E4900, RoHS:YL Sun Fire E6900 Sun Fire E6900, RoHS:YL |
| 595-5306 | 501-5570 [F] | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge S1 |
| 595-5307 | 501-5502 [F] | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 595-5308 | 501-5483 [F] | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 595-5309 | 501-5564 [F] | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 595-5310 | 501-5523 [F] | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| 595-5381 | 540-4591 [F] | Sun Fire 3800 |
| 595-5393 | 300-1441 [F] * | Sun Fire 3800 |
| 595-5715 | 375-0118 [F] | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| 595-5716 | 375-0119 [F] | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge A1000 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L9 |
| 595-5721 | Cabinet Extension Option 4347 Kickplate Extension Right Extension Left Extension Top Extension | Racks Sun Fire 3800 |
| 595-5727 | 501-5030 [F] (512MB) | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 595-5729 | 501-5401 [F] (256MB) | Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| 595-5730 | 540-4193 [F] | Sun Fire 3800 |
| 595-6186 | 540-5086 [F] (1GB) * | Sun Fire 12K / 15K Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 |
| 595-6210 | 300-1529 [F] * | Sun Fire 3800 |
| F375 | Sun Fire x800 systems are subject to a "panic" problem at boot time when a cPCI Dual FC Network Adapter (FRU or X-option) is installed for the first time. If a customer installs this board and boots the system, they will see panic messages on the console and the boot will fail. However, any subsequent reboots will be successful. This may result in an unnecessary service call. This cPCI board (P/N 370-0118-02) has been shipped with Sun Fire X800 systems and as an X-option. The current estimate is that less than 1000 boards have been installed in systems and 1200 boards are in field stock (FRUs and x-options) as of 7/12/01. | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| F3800 | Sun Fire 3800 | Sun Fire 3800 |
| F3800E | Lucent A145 Type A145 AC Input Power Supply Option 4303 | Power Supplies Sun Fire 3800 |
| F501 | SAS Cable Board Assembly (PCI-X), L | I/O Sun Blade 1000 Sun Fire 3800 Sun Fire V445 Sun Fire V480 Sun Netra 20 |
| F511 | Package of 25 × 512MB SDRAM DIMMs | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 |
| X1232A | 501-5570 [F] | SCSI Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge S1 |
| X1234A | 501-5502 [F] | Ethernet Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| X1261A | 501-5523 2 [F] | Ethernet Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| X1266A | 501-5483 [F] | Communication Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| X1268A | 501-5564 [F] | Communication Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| X320A | Localized Power Cord Kit - North America/Asia, | Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire T2000 Sun Fire V125 Sun Fire V210 Sun Fire V215 Server, RoHS:YL Sun Fire V240 Sun Fire V245 Sun Fire V445 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun SPARC Enterprise M3000 Server Sun SPARC Enterprise T2000 Sun SPARC Enterprise T5240 Server Sun SPARC Enterprise T5440 Server Sun StorEdge A3500 Sun Storage 7210 Sun StorageTek 5220 NAS, RoHS:YL Sun StorageTek 5320 NAS Sun StorageTek 5320 NAS, RoHS:YL |
| X3668A | If the Emulex FC HBA card is placed on the same PCI Bus with any other PCI card which causes the Schizo chip to attempt a 64-bit PIO, a system panic would most likely result. The problem will not occur if the Emulex HBA card is installed alone on a PCI Bus. UltraSparc-III platforms utilizing the Schizo 2.1 or 2.2 ASIC may experience panics due to address parity errors on the PCI Bus. The problem has been seen on the Sun Fire 280R with the Emulex FC HBA card in combination with a PGX32 card installed on the same PCI Bus. This condition occurs when a card on the PCI Bus detects a 64-bit parity address error on the PCI Bus while another card on the same PCI Bus is performing a 64-bit PIO. The following error messages are displayed prior to a system panic: WARNING: pcisch-0: PCI fault log start: PCI SERR PCI error occurred on device #6 dwordmask=0 bytemask=0 PCI primary error (0): pcisch-0: PCI secondary error (0): pcisch-0: PBM AFAR 0.00000000: pcisch-0: PCI config space error status (4280): signaled system error. pcisch-0: PCI fault log end. panic[cpu1]/thread=2a10000bd40: pcisch-0: PCI bus 2 error(s)! | Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X3800A | AC Input Power Cable Option (North American, Asian), | Sun Fire 12K / 15K Sun Fire 15K Sun Fire 3800 Sun Fire 6800 Sun Fire E20K Sun Fire E20K, RoHS:YL Sun Fire E25K Sun Fire E6900 Sun Fire E6900, RoHS:YL |
| X3848A | AC Input Power Cable, Harting Han 6HsB to IEC309 (International), | Sun Fire 12K / 15K Sun Fire 15K Sun Fire 3800 Sun Fire 6800 Sun Fire E20K Sun Fire E20K, RoHS:YL Sun Fire E25K Sun Fire E6900 Sun Fire E6900, RoHS:YL |
| X4040A | 540-4591 [F] | Sun Fire 3800 |
| X4303A | 300-1441 [F] | Sun Fire 3800 |
| X4323A | 540-4193 [F] | Sun Fire 3800 |
| X4347A | 595-5721 | Sun Fire 3800 Sun Fire V880 |
| X6748A | 375-0118 [F] | Fibre Channel Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| X6749A | 375-0119 [F] | SCSI Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 |
| X7051A | 2 GB (4 × 512MB SDRAM DIMMs), L | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 |
| X7053A | 1 GB (4 × 256MB SDRAM DIMMs) | Memory Sun Blade 1000 Sun Blade 2000 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V880 Sun Netra 20 |
| X7056A | 4 GB (4 × 1GB SDRAM DIMMs), L | Memory Sun Fire 12K / 15K Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 |
| X800 | cPCI Dual FC Network Adapter ( 375-0118-02) FRU cPCI Dual FC Network Adapter (F375-0118-02) | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 |
| X985A | 530-1869 [F] | Cables Data Cables by Type Cables External Data Cables by Type Sun Enterprise 450 Sun Fire 3800 Sun Fire 4800 Sun Fire 4810 Sun Fire V880 Sun Fire V890 |