Parts for System: Sun StorEdge A5200
| Part Number | Description | Associated Systems |
|---|---|---|
| 180-1954 | Upper Power Cord, NEMA L6-30P to Han 6HsB, Upper Power Cord, Blue 32A IEC 309 to Han 6HsB, Lower Power Cord, NEMA L6-30P to Han 6HsB, Lower Power Cord, Blue 32A IEC 309 to Han 6HsB, Upper Power Cord, Blue 30A Watertight IEC 309 to Han 6HsB, Upper Power Cord, Blue 32A Watertight IEC 309 to Han 6HsB, Lower Power Cord, Blue 30A Watertight IEC 309 to Han 6HsB, Lower Power Cord, Blue 32A Watertight IEC 309 to Han 6HsB, | Racks Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E20K, RoHS:YL Sun Fire E25K Sun StorEdge 3900/6900 Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge 6920 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L500 |
| 180-1955 | Upper Power Cord, NEMA L6-30P to Han 6HsB, Upper Power Cord, Blue 32A IEC 309 to Han 6HsB, Lower Power Cord, NEMA L6-30P to Han 6HsB, Lower Power Cord, Blue 32A IEC 309 to Han 6HsB, Upper Power Cord, Blue 30A Watertight IEC 309 to Han 6HsB, Upper Power Cord, Blue 32A Watertight IEC 309 to Han 6HsB, Lower Power Cord, Blue 30A Watertight IEC 309 to Han 6HsB, Lower Power Cord, Blue 32A Watertight IEC 309 to Han 6HsB, | Racks Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E20K, RoHS:YL Sun Fire E25K Sun StorEdge 3900/6900 Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge 6920 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 240-2690 | A1000/D1000 Key | Sun SPARC(R) Systems that have interlock switch feature. Sun StorEdge A1000 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 |
| 240-4839 | Low Profile Bracket, | Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire T2000 Sun Fire V1280 Sun Fire V20z Sun Fire V210 Sun Fire V240 Sun Fire V245 Sun Fire V40z Sun Fire V440 Sun Fire V445 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L700 Sun Ultra 25 Sun Ultra 45 Sun Ultra 60 Sun Ultra 80 T3 |
| 300-1295 | Zytec EPO71265 310 Watt Power Supply | Power Supplies Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 330-1948 | Upper Left 1" Disk Drive Guide | Sun StorEdge A5200 |
| 330-2000 | Chassis Assembly without Covers, Medium Grey Chassis Assembly with Covers, Medium Grey Top and Bottom Cover, Medium Grey Side Cover, Medium Grey Cover Plug, Medium Grey Foot Backplane Drive Tray Assembly/FRU, Medium Grey Drive Tray Backplane Chassis Subassembly Chassis Power Supply Assembly/FRU, Medium Grey 440 Watt Power Supply Fan Tray Assembly/FRU, Medium Grey 120 × 38 mm Fan, 100CFM | Communication Sun Enterprise 4000 Sun Enterprise 4500 Sun SPARCstorage Array Sun StorEdge A1000 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 |
| 330-2047 | Upper Right 1" Disk Drive Guide | Sun StorEdge A5200 |
| 330-2064 | Front Bottom Cover Rear Bottom Cover | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 330-2106 | Vented Side Panel | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 330-2163 | Front Bottom Cover Rear Bottom Cover | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 340-3289 | Interconnect Board Access Cover | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 340-3290 | Empty Chassis | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 340-3627 | RSM with 3× Disk Drives per Tray RSM with 7× Disk Drives per Tray SPARCstorage RSM Chassis FRU 4.2GB 5400 RPM Disk Drive Assembly/FRU 4.2GB 7200 RPM Disk Drive Assembly/FRU 9.1GB 7200 RPM Disk Drive Assembly/FRU SPARCstorage RSM Shipping Bracket External SCSI Cable, HD68 to HD68, 2.0 M External SCSI Cable, HD68 to HD68, 12.0 M AC Power Cord, AMP Mate-N-Lok to IEC-320 Remote Keyswitch Control Cable, 3.2M AC Power Cord, AMP Mate-N-Lok to Y IEC-320 | Sun SPARCstorage Array Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Systems Disk Array Options StorEdge A3000 Rack |
| 340-3899 | Option X6735A #10-32 × 3/8" Screw (×8) Tray Installation Guide | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 340-4288 | StorEdge D240 Center FRU 12-Slot A1000/D1000 FRU w 1" Bracket 540-3024 w Plate 340-4288 or 340-6640 or Plate 340-5928 or 340-7269 | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 3500 Sun Fire E2900 Sun Fire V120 Sun Netra 120 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge N8200 T3 |
| 340-5262 | Option X9655A Right Side Mounting Rail Right Tray Left Tray Left Side Mounting Rail #10-32 × 3/8" Screw (×10) M6 × 14 mm Screw (×4) Rackmounting Placement Matrix Rackmounting Placement Matrix | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 340-5263 | Option X9655A Right Side Mounting Rail Right Tray Left Tray Left Side Mounting Rail #10-32 × 3/8" Screw (×10) M6 × 14 mm Screw (×4) Rackmounting Placement Matrix Rackmounting Placement Matrix | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 340-5264 | Option X9655A Right Side Mounting Rail Right Tray Left Tray Left Side Mounting Rail #10-32 × 3/8" Screw (×10) M6 × 14 mm Screw (×4) Rackmounting Placement Matrix Rackmounting Placement Matrix | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 340-5265 | Option X9655A Right Side Mounting Rail Right Tray Left Tray Left Side Mounting Rail #10-32 × 3/8" Screw (×10) M6 × 14 mm Screw (×4) Rackmounting Placement Matrix Rackmounting Placement Matrix | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 340-5928 | Netra ct/st/CT/T1/120 FRU NEBS Level 2/3 w 1" Bracket 540-3024 w Plate 340-4288 or Plate 340-6640 or Plate 340-5928 or Plate 340-7269 | Disk (internal) Disks by Part Number Sun Enterprise 10000 Sun Enterprise 3500 Sun Fire 280R Sun Fire E2900 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V250 Server Sun Netra 120 Sun Netra 1280 Server Sun Netra 240 Server Sun Netra 440 Server Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun StorEdge S1 T3 |
| 340-6640 | StorEdge D240 Center FRU 12-Slot A1000/D1000 FRU w 1" Bracket 540-3024 w Plate 340-4288 or 340-6640 or Plate 340-5928 or 340-7269 | Disk (internal) Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 3500 Sun Fire 280R Sun Fire E2900 Sun Fire V120 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 120 Sun Netra 20 Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge N8200 T3 |
| 340-7269 | Netra ct/st/CT/T1/120 FRU NEBS Level 2/3 w 1" Bracket 540-3024 w Plate 340-4288 or Plate 340-6640 or Plate 340-5928 or Plate 340-7269 | Disk (internal) Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 3500 Sun Fire 280R Sun Fire E2900 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V250 Server Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 120 Sun Netra 1280 Server Sun Netra 20 Sun Netra 240 Server Sun Netra 440 Server Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun StorEdge S1 T3 |
| 370-2004 | AC Input Filter | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 370-2303 | This FIN is to inform the field of a new style GBIC that will be shipping with A5X00 Storage Arrays. Installing a FINISAR GBIC in any platform other than A5X00 will result in a restricted access condition which may result in unanticipated downtime. | Allgemein / Unbekannt Disk (external) Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 Sun Ultra 2 T3 |
| 370-2303-01 | The Factory phased in shipments of -03 GBICS beginning early April 1999. A5X00s with chassis s/n greater than 9917 will have the -03 GBIC, or an IBM -02 CD GBIC. These modules appear physically identical to the -02 modules. Field personnel cannot differentiate between module revisions without physically removing them to read the revision level on the connector label. This would require an unacceptable maintenance downtime for host systems.The Vixel -03 Vertical cavity GBICS can be identified as follows: Parts are marked as a -03; this marking can be found on the GBIC connector (system interface connector) as "03a" for -03 revision a. The inside if the cable connector housing will be silver in color on the Vixel vertical cavity (-03) parts; black on the -02 cd laser versions. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 370-2303-02 | A small percentage of Vixel GBICs (370-2303-02) are demonstrating symptoms consistent with marginal signal quality on the GBaud FC-AL loops. Marginal signal quality can be caused by variations in component quality for GBICs, backplanes, interface boards, interconnect assemblies, and FC-AL drives. Symptoms of the GBICs manufactured by Vixel include the following: excessive "CRC Error" or "scsi parity error" messages excessive "OFFLINE" messages excessive "timeout" messages "Offline Timeout" messages | Fibre Channel Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Switches |
| 370-2303-03 | The Factory phased in shipments of -03 GBICS beginning early April 1999. A5X00s with chassis s/n greater than 9917 will have the -03 GBIC, or an IBM -02 CD GBIC. These modules appear physically identical to the -02 modules. Field personnel cannot differentiate between module revisions without physically removing them to read the revision level on the connector label. This would require an unacceptable maintenance downtime for host systems.The Vixel -03 Vertical cavity GBICS can be identified as follows: Parts are marked as a -03; this marking can be found on the GBIC connector (system interface connector) as "03a" for -03 revision a. The inside if the cable connector housing will be silver in color on the Vixel vertical cavity (-03) parts; black on the -02 cd laser versions. | Fibre Channel Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Switches |
| 370-2311 | Display Panel | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 370-2343 | RSM with 3× 4.2GB Disk Drives RSM with 7× 4.2GB Disk Drives SPARCstorage RSM Chassis FRU 4.2GB 5400 RPM Disk Drive Assembly/FRU 4.2GB 7200 RPM Disk Drive Assembly/FRU SPARCstorage RSM Rack Mount Tray SPARCstorage RSM Shipping Bracket External SCSI Cable, HD68 to HD68, 2.0M AC Power Cord, AMP Mate-N-Lok to IEC-320 Remote Keyswitch Control Cable, 3.2M AC Power Cord, AMP Mate-N-Lok to Y IEC-320 Fibre Optical Cable, 2M Fibre Optical Cable, 15M | Sun Enterprise 10000 Sun SPARCstorage Array Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 T3 |
| 370-3012 | FC-100 Hub / Sun StorEdge[tm] F100 Hub | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 370-3592 | AC Power Cord, AMP Mate-N-Lok to Y IEC-320 | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 370-3647 | Seagate ST39102FC [ST39102FSUN9.0G] (9.1GB - 10000 RPM - FC-AL Disk) | Disks by Part Number Sun Enterprise 3500 Sun StorEdge A5200 T3 |
| 370-3722 | Long Wave GBIC Optical Module SC Duplex 9/125 Singlemode Fibre Optical Cable, 15M | Sun StorEdge 3900/6900 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 |
| 370-3975-01 | The Factory phased in shipments of -03 GBICS beginning early April 1999. A5X00s with chassis s/n greater than 9917 will have the -03 GBIC, or an IBM -02 CD GBIC. These modules appear physically identical to the -02 modules. Field personnel cannot differentiate between module revisions without physically removing them to read the revision level on the connector label. This would require an unacceptable maintenance downtime for host systems.The Vixel -03 Vertical cavity GBICS can be identified as follows: Parts are marked as a -03; this marking can be found on the GBIC connector (system interface connector) as "03a" for -03 revision a. The inside if the cable connector housing will be silver in color on the Vixel vertical cavity (-03) parts; black on the -02 cd laser versions. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 370-4035 | StorEdge Network FC Switch-8 and StorEdge Network FC Switch-16 products installed in a Storage Area Network (SAN) configuration must have the proper level of firmware installed for proper operation. All switches in the SAN must contain matching firmware versions. Failure to verify and install the correct switch firmware when installing or replacing switches in a SAN can cause the switch to fail. It is important that the firmware of existing switches in a SAN and any replacement switch be checked for compatibility when installing a new switch into the SAN configuration. | Fibre Channel Sun StorEdge 3900/6900 Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4276 | StorEdge Network FC Switch-8 and StorEdge Network FC Switch-16 products installed in a Storage Area Network (SAN) configuration must have the proper level of firmware installed for proper operation. All switches in the SAN must contain matching firmware versions. Failure to verify and install the correct switch firmware when installing or replacing switches in a SAN can cause the switch to fail. It is important that the firmware of existing switches in a SAN and any replacement switch be checked for compatibility when installing a new switch into the SAN configuration. | Fibre Channel Sun StorEdge 3900/6900 Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4276-01 | Some StorEdge Network FC Switch-16 units were assembled and shipped from the vendor with their mounting brackets reversed. This could potentially result in these switches being installed backwards in the 72-inch StorEdge Expansion Cabinet. This improper installation may cause the inlet temperature of the switch to exceed its recommended range and this could affect the performance and the life of the switch. In addition, the connecting fibre cables might be damaged by hitting the rear cabinet door and may require replacement. | Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 370-4379 | FC-AL Short Wave GBIC | Fibre Channel Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Switches |
| 370-4395 | Brocade 2400 8-port FCAL switch | Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4395-01 | This FIN will explain the field procedure for the installation of Brocade 8 and 16 port switches into a Sun rack. There is no downtime and little customer impact as a result of this issue. | Sun StorEdge 9910/9960 Sun StorEdge A3500 Sun StorEdge A5200 T3 |
| 370-4396 | Brocade 16 port FCAL switch Brocade 16 port switch | Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4396-01 | This FIN will explain the field procedure for the installation of Brocade 8 and 16 port switches into a Sun rack. There is no downtime and little customer impact as a result of this issue. | Sun StorEdge 9910/9960 Sun StorEdge A3500 Sun StorEdge A5200 T3 |
| 370-4863 | Brocade SilkWorm 2250 16-Port FC Switch (6 of these make up the Brocade 6400) | Sun StorEdge A3500 Sun StorEdge A5200 Switches T3 |
| 370-4949-01 | This FIN will explain the field procedure for the installation of Brocade 8 and 16 port switches into a Sun rack. There is no downtime and little customer impact as a result of this issue. | Sun StorEdge 9910/9960 Sun StorEdge A3500 Sun StorEdge A5200 T3 |
| 375-0012 | 32MB SBus NVRAM Board | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 |
| 375-0040 | Any FC-AL PCI loop where A5X00 Storage Arrays are directly connected to i) a host using PCI FC100/P initiator card without hub, or ii) other host (dual host) with FC-AL initiator-card is connected to the same loop may experience the following errors as described in BugId 4243157. Sample error messages: Dec 8 05:18:17 name unix: transport rejected (-2) Dec 8 05:18:17 name unix: Dec 8 05:18:17 name unix: WARNING: /pci@4,4000/SUNW, ifp@4/ssd@w2100002037141659,0 (ssd32) Dec 8 05:18:17 name unix: transport rejected (-2) Dec 8 05:18:17 name unix: Dec 8 05:18:18 name unix: ifp0: LIP occurred Dec 8 05:18:18 name unix: ifp0: Loop up Dec 8 05:18:18 name unix: ifp0: Loop reconfigure in progress Dec 8 05:18:18 name unix: ifp0: Loop reconfigure done Dec 8 08:17:41 name unix: ifp0: Loop down Dec 8 08:17:46 name unix: ifp0: LIP reset occurred UPDATE FOR FIN I0541-2: The Corrective Action on FIN I0541-1 provides two different options or solutions to the above mentioned problems as follows: OPTION-1: The FC100/P card is the only Initiator on any one loop where Sun A5x00 Storage Array are direct connected. OPTION-2: A Sun FCAL hub is placed between the FC100/P card(s), and the A5X00 Storage Array. In this case, more than one host-adapter on the same loop, may be used. Due to resistance from the Field over the cost of implementation, OPTION-2 has been removed from the Corrective Action. This option would have required the customer to purchase and connect a hub to the A5x00 Storage Array. The Corrective Action now recommends only OPTION-1 for avoiding this FC100/P card problem. This restriction is advantageous from high-availability/RAS point of view since having each host on a separate loop removes a single point Of failure (SPOF) in Multi Initiator configurations. | Fibre Channel Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra t1 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-0040-01 | FC100/P FC-AL PCI Card (375-0040-02 or below) | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 60 Sun Ultra 80 |
| 375-0040-02 | A host system using the 375-0040-01 or -02 FC-AL PCI card to attach to FC-AL storage, may experience loop errors which affect data access to that storage. In extreme cases, this can result in the host losing its connection to the storage completely. However, it is more common for the loop errors to be intermittent initially, perhaps becoming more frequent over a period of days or a few weeks. The failures are sometimes sensitive to the data pattern on the FC-AL loop, so they are not always reproducible with current diagnostic software. Below are examples of error messages; unix: ifp0: Loop down unix: ifp0: Loop is down: finishing off loop reconfig unix: ifp0: Loop reconfigure done, LIP unix: WARNING: /pci@1f,2000/SUNW,ifp@1/ssd@w21000020370d323b,0 (ssd58): unix: requeue of command fails (fffffffe) - or - unix: WARNING: /pci@1f,2000/SUNW,ifp@1/ssd@w21000020371430cd,0(ssd2): unix: Error for Command: write(10) Error Level: Retryable unix: Requested Block: 4241 Error Block: 4241 unix: Vendor: SEAGATE Serial Number: 9833X17325 unix: Sense Key: Aborted Command unix: ASC: 0x47 (scsi parity error), ASCQ: 0x0, FRU: 0x3 | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 60 Sun Ultra 80 |
| 375-0087 | Sun StorEdge Fast Write Cache | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 375-0118 | Compact PCI (cPCI) Dual Channel FC | Fibre Channel Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| 375-3019 | PCI Single FC Host Adapter (use for 9840 FC drives) | Fibre Channel Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-3030 | Origin: On X6727A (375-3030) Card - P3 to J3(TX); P4 to J4(RX) Destination: On Expansion Backplane - C to J01100, D to J01101 | Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-3048-01 | In some configurations, after a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging of the FC cable at the FC hub, the SOC+ HBA might intermittently take the FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) received on an idle port of a SOC+ HBA can disrupt I/O activity on the second port of that HBA. | Firmware Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 375-3102 | 2GB PCI Single FC Network Adapter | Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-3108 | 2Gb PCI/PCI-X Dual FC Host Adapter | Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire T2000 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| 375-3383 | 2Gb PCI-X Single FC Host Adapter, | Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire T2000 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V245 Sun Fire V440 Sun Fire V445 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L700 Sun Ultra 25 Sun Ultra 45 Sun Ultra 60 Sun Ultra 80 T3 |
| 390-0011 | Seagate ST318203FC [ST318203FSUN18G] (18.2GB - 10000 RPM - FC-AL Disk) | Disks by Part Number Sun Blade 1000 Sun Enterprise 3500 Sun Fire 280R Sun StorEdge A5200 T3 |
| 390-0016 | Seagate ST39103FC [ST39303FCSUN9.0G] (9.1GB - 10000 RPM - FC-AL Disk) | Disks by Part Number Sun Enterprise 3500 Sun StorEdge A5200 T3 |
| 390-0034 | Seagate ST318304FC [ST3183046SUN18G] (18.2GB - 10000 RPM - FC-AL Disk) | Disks by Part Number Sun Blade 1000 Sun Enterprise 3500 Sun Fire 280R Sun StorEdge A5200 T3 |
| 390-0035 | Storage Expansion Kit, includes: * 6 Slot FC Expansion Backplane 6 - 36.4GB FC Drives | Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Enterprise 3500 Sun Fire 280R Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge A5200 T3 |
| 390-0070 | Storage Expansion Kit, includes: * 6 Slot FC Expansion Backplane 6 - 36.4GB FC Drives | Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Enterprise 3500 Sun Fire 280R Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge A5200 T3 |
| 390-0071 | Storage Expansion.Kit, includes: * 6 Slot FC Expansion Backplane 6 - 73.4GB FC Drives | Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge A5200 T3 |
| 390-0099 | Seagate ST336752FC [ST336752FSUN36G] (36.4GB - 15000 RPM - FC-AL Disk) | Disks by Part Number Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6920 Sun StorEdge A5200 T3 |
| 390-0099-02 | Seagate ST336752FC (36.4GB) disk drives should not be installed into non-RAID configurations. Seagate ST336752FC (36GB) disk drives should only be installed into configurations which use Veritas Volume Manager or SDS RAID software, or hardware RAID configurations. | Sun StorEdge 3900/6900 Sun StorEdge A5200 T3 |
| 390-0101-02 | Seagate ST336752FC (36.4GB) disk drives should not be installed into non-RAID configurations. Seagate ST336752FC (36GB) disk drives should only be installed into configurations which use Veritas Volume Manager or SDS RAID software, or hardware RAID configurations. | Sun StorEdge 3900/6900 Sun StorEdge A5200 T3 |
| 390-0121 | Seagate ST373307FC [ST373307FSUN72G] (73.4GB - 10000 RPM - FC-AL Disk) | Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 6020/6120 Array Sun StorEdge 6130 Array Sun StorEdge 6320 System Sun StorEdge 6920 Sun StorEdge A5200 T3 |
| 390-0130 | Seagate ST336753FC [ST336753FSUN36G] (36.4GB - 15000 RPM - FC-AL Disk) | Disks by Part Number Sun StorEdge 3510 Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6920 Sun StorEdge A5200 T3 |
| 390-0137 | Seagate ST336607FC [ST336607FSUN36G] (36.4GB - 10000 RPM - FC-AL Disk) | Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Enterprise 3500 Sun Fire 280R Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge A5200 T3 |
| 390-0165 | Seagate ST373207FC [ST373207FSUN72G] (73.4GB - 10000 RPM - FC-AL Disk) | Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 6020/6120 Array Sun StorEdge 6130 Array Sun StorEdge 6320 System Sun StorEdge 6920 Sun StorEdge A5200 T3 |
| 501-2947 | Interconnect Board Assembly Vertical Interconnect Board Horizontal Interconnect Board | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-2948 | Interconnect Board Assembly Vertical Interconnect Board Horizontal Interconnect Board | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-2951 | Configured Interface Board FC-AL GBIC Optical Module Interface Board | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-2989-03 | 540-2989 370-2303 501-3060 | Sun StorEdge A5200 |
| 501-2989-04 | 540-2989 370-2303 501-5202 | Sun StorEdge A5200 |
| 501-2989-05 | 540-2989 370-2303 501-5266 | Sun StorEdge A5200 |
| 501-3060 | Configured FC-AL SBus Card <=501-2989-03 FC-AL GBIC Optical Module FC-AL SBus Card | Fibre Channel Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-3060-06 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 |
| 501-4158 | The revision level printed on the labels for the 7-slot Backplane and the 11-slot Backplane for the A5000, A5100, and A5200 array are different than the revision levels that are dynamically reported by the arrays. | Sun StorEdge A5200 |
| 501-4158-03 | StorEdge A5200 with 11 slot HDA (501-4158-03) may fail LBF test in Stortools, and experience various SCSI Errors that are captured in the syslog file (/var/adm/messages). Examples of errors that might be seen are: SCSI Parity CRC SCSI Transport SCSI Transport Reject errors | Sun StorEdge A5200 |
| 501-4158-04 | When replacing either disk, R10 or F10, in slot 10 of an StorEdge A5200 array, a large amount of OFFLINE/ONLINE conditions occur and all disks of the A5200 become inaccessible. When the disk is re-inserted the connectivity is back but time consuming maintenance procedures are necessary. | Sun StorEdge A5200 |
| 501-4266-05 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-4266-08 | In some configurations, after a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging of the FC cable at the FC hub, the SOC+ HBA might intermittently take the FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) received on an idle port of a SOC+ HBA can disrupt I/O activity on the second port of that HBA. | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 501-4372 | The revision level printed on the labels for the 7-slot Backplane and the 11-slot Backplane for the A5000, A5100, and A5200 array are different than the revision levels that are dynamically reported by the arrays. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-4833-01 | In some configurations, after a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging of the FC cable at the FC hub, the SOC+ HBA might intermittently take the FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) received on an idle port of a SOC+ HBA can disrupt I/O activity on the second port of that HBA. | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 501-4883-02 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-4884-02 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-4884-07 | In some configurations, after a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging of the FC cable at the FC hub, the SOC+ HBA might intermittently take the FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) received on an idle port of a SOC+ HBA can disrupt I/O activity on the second port of that HBA. | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 501-5202 | Configured FC-AL SBus Card 501-2989-04 FC-AL GBIC Optical Module FC-AL SBus Card | Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-5202-02 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-5202-03 | Fcode upgrade instructions for the FC100/S Host Adapter supplied with the following luxadm patches can lead to obsolete fcode being installed. 105310 -14 SunOS 5.5.1: Patch for socal, sf driver, and luxadm 105375 -25 SunOS 5.6: sf & socal driver patch 107473 -06 SunOS 5.7: luxadm patch 109529 -03 SunOS 5.8: luxadm, liba5k and libg_fc patch The latest fcode for the FC100/S Host Adapter has been moved to patch 109400 -03 for all versions of Solaris. This change is not reflected in the README files of the luxadm patches currently available ( 105310 , 105375 , 107473 and 109529 ). These patches still provide a lower version of the FC100/S fcode (1.11) and give instructions for installing it. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-5217 | Configured Interface Board FC-AL GBIC Optical Module Interface Board | Sun StorEdge A5200 |
| 501-5266 | Configured FC-AL SBus Card >=501-2989-05 FC-AL GBIC Optical Module FC-AL SBus Board | Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-5266-01 | SBus/FC-AL SOC+ Host Adapters may experience recoverable data transfer read errors. This can result in individual user applications, like Oracle, to stop running. Examples of errors are listed below: SUNWvts /var/adm/messages file xfer errors with Release5 patches installed: Jul 6 11:06:51 tester unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@1,0 (sf1): Jul 6 11:06:51 tester unix: Transport error on target=0x4: Fiber Channel: INCOMPLETE DMA XFER on sbus The message "INCOMPLETE DMA XFER on sbus", indicates that the transfer failed. This is a retryable error and the driver will reissue the I/O. SUNWvts log file xfer compare error with or without Release5 patches installed: Big compare failed on 'device', block 122491, offset 12876 The message indicates that the data transfer to memory does not match that written to the disc. | Firmware Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 501-5266-04 | Fcode upgrade instructions for the FC100/S Host Adapter supplied with the following luxadm patches can lead to obsolete fcode being installed. 105310 -14 SunOS 5.5.1: Patch for socal, sf driver, and luxadm 105375 -25 SunOS 5.6: sf & socal driver patch 107473 -06 SunOS 5.7: luxadm patch 109529 -03 SunOS 5.8: luxadm, liba5k and libg_fc patch The latest fcode for the FC100/S Host Adapter has been moved to patch 109400 -03 for all versions of Solaris. This change is not reflected in the README files of the luxadm patches currently available ( 105310 , 105375 , 107473 and 109529 ). These patches still provide a lower version of the FC100/S fcode (1.11) and give instructions for installing it. | Firmware Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 501-5316 | 11-Slot FC-AL Disk Backplane 7-Slot FC-AL Disk Backplane 7-Slot FC-AL Disk Backplane (not manufactured) | Sun StorEdge A5200 |
| 530-2236 | RSM with 3× Disk Drives per Tray RSM with 7× Disk Drives per Tray SPARCstorage RSM Chassis FRU 4.2GB 5400 RPM Disk Drive Assembly/FRU 4.2GB 7200 RPM Disk Drive Assembly/FRU 9.1GB 7200 RPM Disk Drive Assembly/FRU SPARCstorage RSM Shipping Bracket External SCSI Cable, HD68 to HD68, 2.0 M External SCSI Cable, HD68 to HD68, 12.0 M AC Power Cord, AMP Mate-N-Lok to IEC-320 Remote Keyswitch Control Cable, 3.2M AC Power Cord, AMP Mate-N-Lok to Y IEC-320 | Racks Sun SPARCstorage Array Sun StorEdge 3900/6900 Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge 6920 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Systems Disk Array Options StorEdge A3000 Rack |
| 530-2264 | RSM with 3× Disk Drives per Tray RSM with 7× Disk Drives per Tray SPARCstorage RSM Chassis FRU 4.2GB 5400 RPM Disk Drive Assembly/FRU 4.2GB 7200 RPM Disk Drive Assembly/FRU 9.1GB 7200 RPM Disk Drive Assembly/FRU SPARCstorage RSM Shipping Bracket External SCSI Cable, HD68 to HD68, 2.0 M External SCSI Cable, HD68 to HD68, 12.0 M AC Power Cord, AMP Mate-N-Lok to IEC-320 Remote Keyswitch Control Cable, 3.2M AC Power Cord, AMP Mate-N-Lok to Y IEC-320 | Racks Sun Fire V120 Sun Netra 120 Sun SPARCstorage Array Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Systems Disk Array Options RSM Array 2000 / StorEdge A3000 Systems Disk Array Options StorEdge A3000 Rack |
| 530-2674 | NEMA L6-30P to Han 6HsB, 4.0M, Option 3858 (obsolete) | Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 530-2675 | Blue 32A IEC 309 to Han 6HsB, 4.0M, Option 3859 (obsolete) | Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 537-1004 | RSM with 3× 4.2GB Disk Drives RSM with 7× 4.2GB Disk Drives SPARCstorage RSM Chassis FRU 4.2GB 5400 RPM Disk Drive Assembly/FRU 4.2GB 7200 RPM Disk Drive Assembly/FRU SPARCstorage RSM Rack Mount Tray SPARCstorage RSM Shipping Bracket External SCSI Cable, HD68 to HD68, 2.0M AC Power Cord, AMP Mate-N-Lok to IEC-320 Remote Keyswitch Control Cable, 3.2M AC Power Cord, AMP Mate-N-Lok to Y IEC-320 Fibre Optical Cable, 2M Fibre Optical Cable, 15M | Cables Data Cables by Type Cables External Data Cables by Type Communication Disk (external) Ethernet Fibre Channel Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun SPARCcluster Sun SPARCstorage Array Sun StorEdge 6020/6120 Array Sun StorEdge 6130 Array Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Switches T3 |
| 537-1006 | RSM with 3× 4.2GB Disk Drives RSM with 7× 4.2GB Disk Drives SPARCstorage RSM Chassis FRU 4.2GB 5400 RPM Disk Drive Assembly/FRU 4.2GB 7200 RPM Disk Drive Assembly/FRU SPARCstorage RSM Rack Mount Tray SPARCstorage RSM Shipping Bracket External SCSI Cable, HD68 to HD68, 2.0M AC Power Cord, AMP Mate-N-Lok to IEC-320 Remote Keyswitch Control Cable, 3.2M AC Power Cord, AMP Mate-N-Lok to Y IEC-320 Fibre Optical Cable, 2M Fibre Optical Cable, 15M | Cables Data Cables by Type Cables External Data Cables by Type Communication Disk (external) Ethernet Fibre Channel Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun SPARCcluster Sun SPARCstorage Array Sun StorEdge 3900/6900 Sun StorEdge 6020/6120 Array Sun StorEdge 6130 Array Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Switches T3 |
| 537-1014 | Long Wave GBIC Optical Module SC Duplex 9/125 Singlemode Fibre Optical Cable, 15M | Cables Data Cables by Type Cables External Data Cables by Type Fibre Channel Sun StorEdge A5200 Switches |
| 537-1020 | SunATM-155/MFiber 2.0/2.1/4.0 SunATM-155/MFiber 2.0/2.1/4.0 SunATM-622/MFiber 2.1/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Cables Data Cables by Type Cables External Data Cables by Type Communication Ethernet Fibre Channel Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun StorEdge 6020/6120 Array Sun StorEdge 6130 Array Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Sun StorageTek 5320 NAS Switches T3 |
| 540-2856 | Front Door Assembly | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-2857 | Rear Door Assembly | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-2858 | Front Fan Tray | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-2859 | Rear Fan Tray | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-2864 | Interconnect Board Assembly Vertical Interconnect Board Horizontal Interconnect Board | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-2953 | Front Panel Assembly Front Panel Assembly without Logo | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-2954 | Rear Panel Assembly | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-2988 | Configured Interface Board FC-AL GBIC Optical Module Interface Board | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-2989 | Configured FC-AL SBus Card >=501-2989-05 FC-AL GBIC Optical Module FC-AL SBus Board | Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 540-3024 | Ultra 1, Ultra 2 Ultra 30, Ultra 60, Ultra 80 E250, E450, E220R, E420R Sun Blade 1000 E150, nfs 150, i 150 MultiPack, E3000, E3500 A1000, D1000, A3500 A5000, A5100, A5200, A7000 Netra ct 400, Netra ct 800 st D130, st A1000, st D1000 | Disk (external) Disk (internal) Disk Spud Bracket Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire E2900 Sun Fire E2900, RoHS:YL Sun Fire V120 Sun Fire V125 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V250 Server Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 120 Sun Netra 1280 Server Sun Netra 1280 Server, RoHS:YL Sun Netra 1290, RoHS:YL Sun Netra 20 Sun Netra 240 Server Sun Netra 240 Server, RoHS:YL Sun Netra 440 Server Sun Netra 440 Server, RoHS:YL Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun StorEdge S1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 T3 |
| 540-3344 | Top Door Assembly | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-3348 | Front Panel Assembly Front Panel Assembly without Logo | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 540-3469 | Empty 1" Disk Drive Slot Filler | Sun StorEdge A5200 |
| 540-3707 | 72-inch Cabinet Assembly (595-4706-01) 72-inch Cabinet Assembly (replaced by 540-6290 07/30/04) 72-inch Cabinet | Racks Sun Enterprise 220R Sun Fire 12K / 15K Sun StorEdge 3900/6900 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 T3 |
| 540-3813 | Lower Left 1" Disk Drive Guide | Sun StorEdge A5200 |
| 540-3814 | Lower Right 1" Disk Drive Guide | Sun StorEdge A5200 |
| 540-3869 | Empty backplane/incorrect configuration on StorEdge A5x00 can Cause Errors. This minimum configuration is a requirement because circuitry on the disk drives regenerate and retime the data signals which corrects signal quality loss accumulated through the bypass circuitry between empty slots. Empty backplanes can generate errors which are intermittent and difficult to isolate. Error message examples: Jun 6 20:48:11 depth unix: sf0: Target 0x12 Reset Failed. Ret=105 Jun 6 20:48:11 depth unix: sf0: sf_reset all Jun 6 20:48:11 depth unix: ID[SUNWssa.socal.link.5010] socal0: port 0: Fibre Channel is OFFLINE Jun 6 20:48:11 depth unix: WARNING: /sbus@1f,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037070d4c,0 (ssd8): Jun 6 20:48:11 depth unix: SCSI transport failed: reason 'timeout': retrying command Jun 6 20:48:11 depth unix: ID[SUNWssa.socal.link.6010] socal0: port 0: Fibre Channel Loop is ONLINE Jun 6 20:48:13 depth unix: sf0: ELS 0x0 to target 0x1d retrying Jun 6 21:00:07 depth unix: WARNING: /sbus@1f,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037070d5a,0 (ssd5): Jun 6 21:00:07 depth unix: Error for Command: read(10) Error Level: Retryable | Disks by Part Number Sun Enterprise 3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-3869-01 | Seagate Cheetah 3 FCAL disk drives may experience higher than expected failure rate. | Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-3964 | Sun StorEdge A5200 Chassis without Skins | Sun StorEdge A5200 |
| 540-4026-01 | In some configurations, after a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging of the FC cable at the FC hub, the SOC+ HBA might intermittently take the FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) received on an idle port of a SOC+ HBA can disrupt I/O activity on the second port of that HBA. | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-4033 | Configured Interface Board FC-AL GBIC Optical Module Interface Board | Sun StorEdge A5200 |
| 540-4098 | Sun StorEdge A5200 Chassis without Skins | Sun StorEdge A5200 |
| 540-4191 | Empty backplane/incorrect configuration on StorEdge A5x00 can Cause Errors. This minimum configuration is a requirement because circuitry on the disk drives regenerate and retime the data signals which corrects signal quality loss accumulated through the bypass circuitry between empty slots. Empty backplanes can generate errors which are intermittent and difficult to isolate. Error message examples: Jun 6 20:48:11 depth unix: sf0: Target 0x12 Reset Failed. Ret=105 Jun 6 20:48:11 depth unix: sf0: sf_reset all Jun 6 20:48:11 depth unix: ID[SUNWssa.socal.link.5010] socal0: port 0: Fibre Channel is OFFLINE Jun 6 20:48:11 depth unix: WARNING: /sbus@1f,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037070d4c,0 (ssd8): Jun 6 20:48:11 depth unix: SCSI transport failed: reason 'timeout': retrying command Jun 6 20:48:11 depth unix: ID[SUNWssa.socal.link.6010] socal0: port 0: Fibre Channel Loop is ONLINE Jun 6 20:48:13 depth unix: sf0: ELS 0x0 to target 0x1d retrying Jun 6 21:00:07 depth unix: WARNING: /sbus@1f,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037070d5a,0 (ssd5): Jun 6 21:00:07 depth unix: Error for Command: read(10) Error Level: Retryable | Disks by Part Number Sun Enterprise 3500 Sun Fire 280R Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-4191-01 | Seagate Cheetah 3 FCAL disk drives may experience higher than expected failure rate. | Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-4191-02 | 18GB | Sun Enterprise 3500 Sun StorEdge A5200 T3 |
| 540-4192-01 | Seagate Cheetah 3 FCAL disk drives may experience higher than expected failure rate. | Sun Enterprise 3500 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-4367-01 | Sun StorEdge T3 Arrays containing Seagate Cheetah 4 18GB/36GB/73GB drives with firmware versions prior to A72x may experience severe performance degradation due to fatal drive timeouts. | Sun Enterprise 3500 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-4372 | StorEdge Network FC Switch-8 and StorEdge Network FC Switch-16 products installed in a Storage Area Network (SAN) configuration must have the proper level of firmware installed for proper operation. All switches in the SAN must contain matching firmware versions. Failure to verify and install the correct switch firmware when installing or replacing switches in a SAN can cause the switch to fail. It is important that the firmware of existing switches in a SAN and any replacement switch be checked for compatibility when installing a new switch into the SAN configuration. | Fibre Channel Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire V1280 Sun Netra 1280 Server Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3511 FC Array Sun StorEdge 3900/6900 Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Sun StorEdge L5500 Sun StorEdge L8500 Tape Library Switches T3 |
| 540-4440-01 | Sun StorEdge T3 Arrays containing Seagate Cheetah 4 18GB/36GB/73GB drives with firmware versions prior to A72x may experience severe performance degradation due to fatal drive timeouts. | Sun Enterprise 3500 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-4525 | 18.2GB 10000 RPM Disk Drive Assembly/FRU 36.4GB 10000 RPM Disk Drive Assembly/FRU 73.4GB 10000 RPM Disk Drive Assembly/FRU 73.4GB 10000 RPM Disk Drive Assembly/FRU | Disk (external) Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Enterprise 3500 Sun Fire 280R Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-4525-01 | Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible to label corruption. | Sun Blade 1000 Sun Blade 2000 Sun Enterprise 3500 Sun Fire 280R Sun Fire V880 Sun Netra 20 Sun StorEdge A5200 T3 |
| 540-4673-01 | Seagate Cheetah 3 FCAL disk drives may experience higher than expected failure rate. | Sun Enterprise 3500 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 540-4751 | StorEdge Network FC Switch-8 and StorEdge Network FC Switch-16 products installed in a Storage Area Network (SAN) configuration must have the proper level of firmware installed for proper operation. All switches in the SAN must contain matching firmware versions. Failure to verify and install the correct switch firmware when installing or replacing switches in a SAN can cause the switch to fail. It is important that the firmware of existing switches in a SAN and any replacement switch be checked for compatibility when installing a new switch into the SAN configuration. | Fibre Channel Sun StorEdge 3510 Sun StorEdge 3511 FC Array Sun StorEdge 3900/6900 Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Sun StorEdge L5500 Sun StorEdge L8500 Tape Library Switches T3 |
| 540-4905 | 18.2GB 10000 RPM Disk Drive Assembly/FRU 36.4GB 10000 RPM Disk Drive Assembly/FRU 73.4GB 10000 RPM Disk Drive Assembly/FRU 73.4GB 10000 RPM Disk Drive Assembly/FRU | Disk (external) Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire V880 Sun Fire V890 Sun StorEdge A5200 T3 |
| 540-4905-01 | Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible to label corruption. | Sun Blade 1000 Sun Blade 2000 Sun Enterprise 3500 Sun Fire 280R Sun Fire V880 Sun Netra 20 Sun StorEdge A5200 T3 |
| 540-5178 | 36.4GB - 15000 RPM FC-AL, Disk Assembly with 1 bracket, and 1 of the following plates, and 1 of the following disks: | Disks by Part Number Sun StorEdge A5200 T3 |
| 540-5178-01 | Seagate ST336752FC (36.4GB) disk drives should not be installed into non-RAID configurations. Seagate ST336752FC (36GB) disk drives should only be installed into configurations which use Veritas Volume Manager or SDS RAID software, or hardware RAID configurations. | Sun StorEdge 3900/6900 Sun StorEdge A5200 T3 |
| 540-5179-01 | Seagate ST336752FC (36.4GB) disk drives should not be installed into non-RAID configurations. Seagate ST336752FC (36GB) disk drives should only be installed into configurations which use Veritas Volume Manager or SDS RAID software, or hardware RAID configurations. | Sun StorEdge 3900/6900 Sun StorEdge A5200 T3 |
| 595-3378 | 537-1004 [F] | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 595-3379 | 537-1006 [F] | Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 595-4303 | 540-2989 501-5266 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| 595-4357 | 300-1295 [F] | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 595-4358 | 501-2951 [F] | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 595-4359 | 370-2303 [F] | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| 595-4362 | 370-3012 [F] | Sun StorEdge A3500 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 595-4488 | 375-0012 [F] | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 |
| 595-4551 | Option X6735A #10-32 × 3/8" Screw (×8) Tray Installation Guide | Racks Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 595-4685 | 375-0040 [F] | Fibre Channel Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra t1 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 60 Sun Ultra 80 T3 |
| 595-4938 | 540-3869 [F] Spud Bracket FRU w/ 1" Bracket 540-3024 w/ Plate 340-4288 or 340-6640 or 340-5928 or 340-7269 | Sun Enterprise 3500 Sun StorEdge A5200 |
| 595-4940 | Option X9654A Right Side Mounting Rail Tray Left Side Mounting Rail #10-32 × 3/8" Screw (×10) M6 × 14 mm Screw (×4) Rackmounting Placement Matrix Rackmounting Placement Matrix | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 595-4951 | Option X9655A Right Side Mounting Rail Right Tray Left Tray Left Side Mounting Rail #10-32 × 3/8" Screw (×10) M6 × 14 mm Screw (×4) Rackmounting Placement Matrix Rackmounting Placement Matrix | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 595-4954 | Option X9819A Fan Tray Assembly (×2) Cable, Fan Tray to J4 on AC Sequencer (×2) Fan Tray Top Panel StorEdge Expansion Cabinet Fan Tray Installation Guide | Racks Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E25K Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 595-4999 | Sun Fire Link Switch Option X4170A Sun Fire Link Switch Option 4170A AC Power Cord cPCI Filler Panel Tested Switch Assembly System Controller WCIX Module Switch Assembly 150W Power Supply Fan Tray Switch Chassis Assembly Chassis Backplane + AC Harness + AC Module | Racks Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E25K Sun Fire V880 Sun Fire V890 Sun StorEdge 3900/6900 Sun StorEdge 6900 series Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge L500 Switches |
| 595-5031 | 370-3722 [F] * | Sun StorEdge 3900/6900 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 |
| 595-5139 | 375-0087 [F] | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 595-5216 | 540-4191 [F] Spud Bracket FRU w/ 1" Bracket 540-3024 w/ Plate 340-5928 or 340-6640 or 340-7269 | Sun Enterprise 3500 Sun Fire 280R Sun StorEdge A5200 |
| 595-5463 | 375-0087 [F] | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 595-5494 | 540-4525 [F] Spud Bracket FRU w/ 1" Bracket 540-3024 w/ Plate 340-6640 or Plate 340-7269 | Sun Blade 1000 Sun Enterprise 3500 Sun Fire 280R Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun StorEdge A5200 |
| 595-5608 | 537-1020 [F] | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| 595-5715 | 375-0118 [F] | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| 595-5800 | Network FC Switch-16 Option SG-XSW16-32P AC Y Power Cord (Option X319YA) 2U-3U Mounting Rail 2U Vented Panel Switch Assembly/FRU Left Bracket Right Bracket Rear Bracket Ancor SANbox-16 Switch | Fibre Channel Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge L5500 Switches T3 |
| 595-5816 | Current switch replacement procedures for the 39x0 & 69x0 are incorrect. | Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra 20 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| 595-5830 | 375-3019 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun Ultra 60 Sun Ultra 80 |
| 595-5853 | 375-3030 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun Ultra 60 Sun Ultra 80 T3 |
| 595-5961 | 540-4905 [F] Spud Bracket FRU w/ 1" Bracket 540-3024 w/ Plate 340-6640 or Plate 340-7269 | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire V880 Sun StorEdge A5200 |
| 595-6247 | 540-5178 [F] Spud Bracket FRU w 1" Bracket 540-3024 w Plate 340-6640 or Plate 340-7269 | Sun StorEdge A5200 |
| 595-6425 | 375-3102 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun StorEdge 3900/6900 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun Ultra 60 Sun Ultra 80 T3 |
| 595-6426 | 375-3108 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun StorEdge 3900/6900 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun Ultra 60 Sun Ultra 80 T3 |
| 798-2205-01 | There is confusion with regard to supporting the A5x00 products with hubs attached and the use of Volume Manager version 3.0.2. This confusion came from the Veritas Volume Manager Hardware Application Note Release 3.0.2, which states on page 12... "Dynamic Multi Pathing (DMP) does not support hub-attached A5000, A5100, and A5200 arrays at this time. See your sales representatives for details about DMP support plans for this configuration." If the above recommendation is not followed, then the system could encounter catastrophic results. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| 798-2832-01 | When used on a heavily loaded system to monitor multiple enclosures, Component Manager response time can be longer than expected. | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| F100 | 550MHz UltraSPARC IIi FRU w/ Ground Ring 550MHz UltraSPARC IIi KFAB 650MHz UltraSPARC IIi KFAB (deviation WO_25102) 550MHz/DB650MHz UltraSPARC IIi | Sun Blade 150 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| X1075A | 375-0012 [F] | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 |
| X3858A | AC Power Cord, Han 6HsB to NEMA L6-30P (US) 4M, | Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E20K, RoHS:YL Sun Fire E25K Sun StorEdge 3900/6900 Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge 6920 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L500 |
| X3859A | Han 6HsB to Blue 32A IEC309 (Intl), | Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E20K, RoHS:YL Sun Fire E25K Sun StorEdge 3900/6900 Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge 6920 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| X6710A | 540-3869 [F] | Sun Enterprise 3500 Sun StorEdge A5200 |
| X6720A | 540-4191 [F] | Sun Enterprise 3500 Sun Fire 280R Sun StorEdge A5200 |
| X6724A | 540-4525 [C] | Sun Blade 1000 Sun Blade 2000 Sun Enterprise 3500 Sun Fire 280R Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge A5200 |
| X6727A | Origin: On X6727A (375-3030) Card - P3 to J3(TX); P4 to J4(RX) Destination: On Expansion Backplane - C to J01100, D to J01101 | Allgemein / Unbekannt Fibre Channel Sun Blade 1000 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| X6729A | 375-0040 [C] | Fibre Channel Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra t1 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 60 Sun Ultra 80 T3 |
| X6730A | 595-4303 | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun Ultra 2 T3 |
| X6731A | This FIN is to inform the field of a new style GBIC that will be shipping with A5X00 Storage Arrays. Installing a FINISAR GBIC in any platform other than A5X00 will result in a restricted access condition which may result in unanticipated downtime. | Disk (external) Fibre Channel Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge 3900/6900 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 Sun Ultra 2 T3 |
| X6732A | 370-3012 [F] | Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| X6734A | 595-4358 | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| X6735A | 595-4551 240-1396 340-3899 805-0315 | Racks Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 T3 |
| X6737A | 370-3722 5 [F] | Cables Data Cables by Type Cables External Data Cables by Type Sun StorEdge 3900/6900 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 |
| X6738A | 375-0087 [F] | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| X6742A | 540-4905 [C] | Sun Blade 1000 Sun Blade 2000 Sun Fire 280R Sun Fire V880 Sun Fire V890 Sun StorEdge A5200 |
| X6745A | 375-0087 [F] | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| X6746A | 595-5358 595-5560 180-1932 540-4189 540-4372 340-5773 370-4035 | Fibre Channel Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire V1280 Sun Netra 1280 Server Sun Netra 20 Sun StorEdge 3900/6900 Sun StorEdge 6020/6120 Array Sun StorEdge 6320 System Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Sun StorEdge L5500 Sun StorEdge L8500 Tape Library Switches T3 |
| X6748A | 375-0118 [F] | Fibre Channel Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L5500 T3 |
| X6763A | 540-5178 [F] | Sun StorEdge A5200 |
| X6767A | 375-3102 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| X6768A | 375-3108 [F] | Fibre Channel Sun Blade 1000 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| X6799A | 375-3019 15 [C] | Fibre Channel Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3510 Sun StorEdge 3900/6900 Sun StorEdge 6920 Sun StorEdge 9990 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L180 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun Ultra 60 Sun Ultra 80 T3 |
| X9654A | 595-4940 340-4042 340-5261 340-4043 240-1396 240-2083 802-6945 805-4748 | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| X9655A | 595-4951 340-5262 340-5264 340-5265 340-5263 240-1396 240-2083 802-6945 805-4748 | Racks Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| X9687A | 300-1295 [F] | Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |
| X9715A | 537-1020 [F] | Cables Data Cables by Type Cables External Data Cables by Type Fibre Channel Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun StorEdge 6020/6120 Array Sun StorEdge 6130 Array Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Switches T3 |
| X973A | 370-2303 [F] 537-1004 [F] 537-1006 [F] | Cables Data Cables by Type Cables External Data Cables by Type Disk (external) Fibre Channel Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun StorEdge 6020/6120 Array Sun StorEdge 6130 Array Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Switches T3 |
| X978A | 370-2303 [F] 537-1004 [F] 537-1006 [F] | Cables Data Cables by Type Cables External Data Cables by Type Disk (external) Fibre Channel Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun StorEdge 3900/6900 Sun StorEdge 6020/6120 Array Sun StorEdge 6130 Array Sun StorEdge 6900 series Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge L100 Tape Library Sun StorEdge L25 Tape Library Switches T3 |
| X9818A | 595-4999 370-3675 None None None None None 805-5992 | Racks Sun Fire 12K / 15K Sun Fire 15K Sun Fire E20K Sun Fire E25K Sun Fire V880 Sun Fire V890 Sun StorEdge 3900/6900 Sun StorEdge 6900 series Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge L500 |
| X9819A | 595-4954 540-3887 530-2236 340-5285 805-5774 | Racks Sun Fire E20K Sun Fire E25K Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge A5200 |