Parts for System: Sun StorEdge L1000

<< Back to Systems Overview

Part NumberDescriptionAssociated Systems
150-1890Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68Cables Data Cables by Type
Cables External Data Cables by Type
Disk (external)
SCSI
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge N8200
Systems Disk Array Options RSM Array 2000 / StorEdge A3000
Systems Library Options ETL 4/1000
330-1651Chassis Assembly Chassis Front Bezel Assembly Front EMI Cover SCSI Tray 650 Watt Power Supply Power Key M6 × 14 mm Screw, Foot Top and Bottom Cover Side Cover (obsolete) Side Cover (required if SM81 is installed) Cover Plug Foot 185 CFM Fan Tray Assy, +12Vdc, 4 Amps 6" Fans, 60 CFM @ 1850 RPM @ 0.05" H 2 O 6" Fans, 80 CFM @ 2950 RPM @ 0.15" H 2 O 4.7" Fan, 45 CFM @ 2300 RPM @ 0.9" H 2 O 4-Slot XDBus Backplane #2-56 Nylon Nut Guide Pin M3 × 8 mm Screw (obsolete) M3 × 6 mm Screw Empty Slot Filler PanelSun Enterprise 3000
Sun Enterprise 4000
Sun Enterprise 5000
Sun Enterprise 5000/6000 Data Center Cabinet
Sun Enterprise 6000
Sun SPARC(R) Systems that have interlock switch feature.
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L140
Sun StorEdge L400
Sun4d System SPARCcenter 2000 and 2000E
Sun4d System SPARCserver 1000 and 1000E
Systems Library Options SPARCstorage Library Model 8/140
370-1703When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver.MediaCenter
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge S1
Sun Ultra 2
370-1704When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver.Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L20 / L40 / L60
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L9
Sun Ultra 2
370-2188Digital Linear Tape Compact IV cartridge, package of 10 (Option SG-XMEDDLTCIV-10)Removable Media
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Systems Library Options ETL 4/1000
Systems Library Options SPARCstorage DLT4700
370-2188-01The StorEdge DLT tape drives may encounter problems with swallowed or damaged leaders during the tape load or unloading process if faulty DLT cartridge tapes are in use. This FIN has been issued with the intent to assist Enterprise Services field personnel with the identification of defective DLT cartridge tapes which could cause damage to the StorEdge DLT tape drive.Sun StorEdge L1000
Sun StorEdge L3500
370-2189Digital Linear Tape cleaning cartridges, package of 10 (Option SG-XMEDDLTCL-10)Removable Media
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Systems Library Options ETL 4/1000
Systems Library Options SPARCstorage DLT4700
370-2189-01The StorEdge DLT tape drives may encounter problems with swallowed or damaged leaders during the tape load or unloading process if faulty DLT cartridge tapes are in use. This FIN has been issued with the intent to assist Enterprise Services field personnel with the identification of defective DLT cartridge tapes which could cause damage to the StorEdge DLT tape drive.Sun StorEdge L1000
Sun StorEdge L3500
370-2443When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver.SCSI
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun Ultra 2
370-2443-01Intermittently, SCSI devices connected to a UDWIS card may not be usable after a reboot. This can prevent a system from booting if the UDWIS card connected to the boot device is affected. This problem is due to some issues in FCode versions less than 1.28 in the UDWIS card. When it is booting, the card fails to send a SCSI bus reset, or the SCSI bus reset is not held long enough to meet the SCSI specification, or the card fails to initialize correctly. This leads to the attached SCSI devices failing to negotiate correctly with the host.Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L3500
Sun StorEdge L7
370-2443-02Any system installed with a UDWIS/S (isp-fcode 1.28) has the possibility of displaying "invalid command" messages during POST, "probe-scsi-all" at the ok prompt, booting IF the variable "diag-switch?" is set to "true", or boot -hv from external storage..Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L3500
Sun StorEdge L7
370-2847The /kernel/drv/st.conf file entries are incorrect in Solaris 2.5.1 and 2.6 for the DLT7000 drive. The use of an incorrect st.conf file entry will cause tape format incompatibility and poor device performance. In addition, the host system will not recognize the tape device as a DLT- 7000, but as a generic tape device and will assign improper tape density codes and device type to tape drive. Example shown below: The incorrect st.conf file entry is as follows: "Quantum DLT7000", "Quantum DLT7000", "DLT7k-data", DLT7k-data = 1,0x36,0,0x1D639,4,0x82,0x83,0x84,0x85,2;Removable Media
Sun StorEdge L1000
Sun StorEdge L3500
370-3516DLT 7000 drive Take-Up Leader and Cartridge Leader misalignment may cause the unit to fail. most of the reported problems in reference to the DLT7000 failures stem from the current firmware rev. (v72 or older) of the DLT7000 tape drive which does not allow the normal "Buckling Process" of the Take-Up Leader and Cartridge Leader to align properly and insure alignment of the Take-Up Leader and Cartridge Leader. A new DLT firmware version (v85 or newer) has been released that will correct many of the various failure conditions.Sun StorEdge L1000
Sun StorEdge L3500
370-3516-01DLT 7000 drive Take-Up Leader and Cartridge Leader misalignment may cause the unit to fail.Sun StorEdge L1000
370-3517Y-Axis 2-Phase Stepper MotorSun StorEdge L1000
370-3518X-Axis 2-Phase Stepper MotorSun StorEdge L1000
370-351924V, 41 CFM FanSun StorEdge L1000
370-352024V, 90 CFM FanSun StorEdge L1000
370-3521Differential Ultra/Wide SCSI ControllerSun StorEdge L1000
370-3522X-Axis Timing Belt, 1/4" WideSun StorEdge L1000
370-3523Y-Axis Timing Belt, 3/8" WideSun StorEdge L1000
370-3524Right Front Door Assembly with Control PanelSun StorEdge L1000
370-3525Robotics Controller BoardSun StorEdge L1000
370-3526Actuator Driver BoardSun StorEdge L1000
370-3527Y-Encode BoardSun StorEdge L1000
370-3528X-Motor Interconnect BoardSun StorEdge L1000
370-3529Extension Axis AssemblySun StorEdge L1000
370-35308-Cartridge Bulk/Load Pack AssemblySun StorEdge L1000
370-3531Power Supply without Switch (-02: ATL p/n 6220571)Sun StorEdge L1000
370-35325-Slot BackplaneSun StorEdge L1000
370-35444 Packages of 99 Data Barcode LabelsSun StorEdge L1000
Sun StorEdge L11000
370-3545External SCSI Cable, 90° HD68 to 90° HD68, 18 cmCables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun StorEdge L1000
370-3546External SCSI Cable, 90° HD68 to 90° HD68, 36 cmCables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun StorEdge L1000
370-3622Slide RailSun StorEdge L1000
370-3627Left Single Fan with BracketSun StorEdge L1000
370-3628Right Double Fan with BracketSun StorEdge L1000
370-36291 Package of 33 Cleaning Tape BarcodeSun StorEdge L1000
Sun StorEdge L11000
375-0006SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected.SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
375-0119Dual Differential Ultra SCSI, cPCI (Use for DLT8000)SCSI
Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
380-0074Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000Sun StorEdge L1000
380-0075Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000Sun StorEdge L1000
380-0076Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000Sun StorEdge L1000
380-0077Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000Sun StorEdge L1000
380-0519Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000Sun StorEdge L1000
380-0520Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000Sun StorEdge L1000
380-0521DLT 8000 Tape Drive for L1000Sun StorEdge L1000
530-2352Expansion Cabinet, Option 9641 (two trays maximum) Tray Assembly #10-32 × 1/2" Screw (×16) Removable Storage Tray Rack Mount Bracket (×2) External SCSI Cable, HD68 to HD68, 4MCables Data Cables by Type
Cables External Data Cables by Type
Racks
SCSI
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge S1
Systems Library Options ETL 4/1000
565-1477Service Kit with Tools, Manuals, and DiagnosticsSun StorEdge L1000
595-3257370-1704 [F]Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge L1000
Sun StorEdge L20 / L40 / L60
Sun StorEdge L3500
Sun StorEdge L9
Sun Ultra 2
595-4187370-2443 [F]Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L9
Sun Ultra 2
595-4414375-0006 [F]SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V480
Sun Fire V880
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
595-4854370-3516 [F]Sun StorEdge L1000
595-5716375-0119 [F]Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L9
595-6224380-0521 [F]Sun StorEdge L1000
704-56846210160 6210151 0425003 6210150 6211266 None 6211222 6211221 6211223 6211224Sun StorEdge L1000
Sun StorEdge L180
Systems Library Options ETL 4/1000
704-6219Sun StorEdge L1000 Service CD-ROM Reference CD-ROM and LibMON[tm] 1.1 PatchSun StorEdge L1000
794-7575-01Networker may attempt to position a DLT7000 volume to read the label before the drive has completed the load sequence. The DLT7000 has a minimum load time of 48 seconds (previously written) this time may be longer if the tape is blank. The networker product has no understanding of the DLTs "time to load" or for that matter, any other tape library's "time to load" value, and may attempt to position the volume to read the label prior to the drive being at BOT. Should this be the case, one of the following errors may be returned during the mount request: tape: verify label operation in progress media warning:tape opening io error open errorSun StorEdge L1000
Sun StorEdge L3500
798-0508-01Sun StorEdge LibMON 2.0 is currently supported on Solaris(TM) operating environment releases 2.5.1 and 2.6. Thus, customers wanting to run StorEdge LibMON/LibAgent 2.0 on Solaris 7 are unable to do so. In response to the above mentioned problem with StorEdge LibMON 2.0, patches 108014-01, 108015-01, 108016-01 and 108017-1 have been released to the SunSolve database. (9-23-99)Sun StorEdge L1000
Sun StorEdge L3500
798-1365-01UPDATED FIN. StorEdge LibMON/LibAgent 2.0 does not provide support for L280 and L11000 libraries.Sun StorEdge L1000
805-4822Sun StorEdge L1000 Unpacking Instructions Sun StorEdge L1000 User's Guide Control Panel Password InstructionsSun StorEdge L1000
805-4823Sun StorEdge L1000 Unpacking Instructions Sun StorEdge L1000 User's Guide Control Panel Password InstructionsSun StorEdge L1000
805-5577StorEdge L11000 Reference CD-ROM StorEdge L11000 Service CD-ROM Control Panel Password Instructions StorEdge L11000 Users Guide StorEdge L11000 Service Manual StorEdge L11000 Unpacking Instructions StorEdge L11000 Uncrating InstructionsSun StorEdge L1000
Sun StorEdge L11000
855-5008-01Sun StorEdge LibMON 2.0 is currently supported on Solaris(TM) operating environment releases 2.5.1 and 2.6. Thus, customers wanting to run StorEdge LibMON/LibAgent 2.0 on Solaris 7 are unable to do so. In response to the above mentioned problem with StorEdge LibMON 2.0, patches 108014-01, 108015-01, 108016-01 and 108017-1 have been released to the SunSolve database. (9-23-99)Sun StorEdge L1000
Sun StorEdge L3500
X1062A370-1704 [F]Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge L1000
Sun StorEdge L20 / L40 / L60
Sun StorEdge L3500
Sun StorEdge L9
Sun Ultra 2
X1065A370-2443 [F]SCSI
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun Ultra 2
X3810A530-2352 [F]Cables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun StorEdge 3120
Sun StorEdge L1000
Sun StorEdge L3500
Sun StorEdge S1
X6541ASCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected.Allgemein / Unbekannt
SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
X6749A375-0119 [F]SCSI
Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9