Parts for System: Sun StorEdge L1000
| Part Number | Description | Associated Systems |
|---|---|---|
| 150-1890 | Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68 | Cables Data Cables by Type Cables External Data Cables by Type Disk (external) SCSI Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L11000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L280 Sun StorEdge L3500 Sun StorEdge L7 Sun StorEdge L9 Sun StorEdge N8200 Systems Disk Array Options RSM Array 2000 / StorEdge A3000 Systems Library Options ETL 4/1000 |
| 330-1651 | Chassis Assembly Chassis Front Bezel Assembly Front EMI Cover SCSI Tray 650 Watt Power Supply Power Key M6 × 14 mm Screw, Foot Top and Bottom Cover Side Cover (obsolete) Side Cover (required if SM81 is installed) Cover Plug Foot 185 CFM Fan Tray Assy, +12Vdc, 4 Amps 6" Fans, 60 CFM @ 1850 RPM @ 0.05" H 2 O 6" Fans, 80 CFM @ 2950 RPM @ 0.15" H 2 O 4.7" Fan, 45 CFM @ 2300 RPM @ 0.9" H 2 O 4-Slot XDBus Backplane #2-56 Nylon Nut Guide Pin M3 × 8 mm Screw (obsolete) M3 × 6 mm Screw Empty Slot Filler Panel | Sun Enterprise 3000 Sun Enterprise 4000 Sun Enterprise 5000 Sun Enterprise 5000/6000 Data Center Cabinet Sun Enterprise 6000 Sun SPARC(R) Systems that have interlock switch feature. Sun StorEdge L1000 Sun StorEdge L11000 Sun StorEdge L140 Sun StorEdge L400 Sun4d System SPARCcenter 2000 and 2000E Sun4d System SPARCserver 1000 and 1000E Systems Library Options SPARCstorage Library Model 8/140 |
| 370-1703 | When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver. | MediaCenter Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L3500 Sun StorEdge L7 Sun StorEdge L9 Sun StorEdge S1 Sun Ultra 2 |
| 370-1704 | When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L20 / L40 / L60 Sun StorEdge L3500 Sun StorEdge L7 Sun StorEdge L9 Sun Ultra 2 |
| 370-2188 | Digital Linear Tape Compact IV cartridge, package of 10 (Option SG-XMEDDLTCIV-10) | Removable Media Sun StorEdge L1000 Sun StorEdge L11000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L280 Sun StorEdge L3500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Systems Library Options ETL 4/1000 Systems Library Options SPARCstorage DLT4700 |
| 370-2188-01 | The StorEdge DLT tape drives may encounter problems with swallowed or damaged leaders during the tape load or unloading process if faulty DLT cartridge tapes are in use. This FIN has been issued with the intent to assist Enterprise Services field personnel with the identification of defective DLT cartridge tapes which could cause damage to the StorEdge DLT tape drive. | Sun StorEdge L1000 Sun StorEdge L3500 |
| 370-2189 | Digital Linear Tape cleaning cartridges, package of 10 (Option SG-XMEDDLTCL-10) | Removable Media Sun StorEdge L1000 Sun StorEdge L11000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L280 Sun StorEdge L3500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Systems Library Options ETL 4/1000 Systems Library Options SPARCstorage DLT4700 |
| 370-2189-01 | The StorEdge DLT tape drives may encounter problems with swallowed or damaged leaders during the tape load or unloading process if faulty DLT cartridge tapes are in use. This FIN has been issued with the intent to assist Enterprise Services field personnel with the identification of defective DLT cartridge tapes which could cause damage to the StorEdge DLT tape drive. | Sun StorEdge L1000 Sun StorEdge L3500 |
| 370-2443 | When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver. | SCSI Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun Ultra 2 |
| 370-2443-01 | Intermittently, SCSI devices connected to a UDWIS card may not be usable after a reboot. This can prevent a system from booting if the UDWIS card connected to the boot device is affected. This problem is due to some issues in FCode versions less than 1.28 in the UDWIS card. When it is booting, the card fails to send a SCSI bus reset, or the SCSI bus reset is not held long enough to meet the SCSI specification, or the card fails to initialize correctly. This leads to the attached SCSI devices failing to negotiate correctly with the host. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L3500 Sun StorEdge L7 |
| 370-2443-02 | Any system installed with a UDWIS/S (isp-fcode 1.28) has the possibility of displaying "invalid command" messages during POST, "probe-scsi-all" at the ok prompt, booting IF the variable "diag-switch?" is set to "true", or boot -hv from external storage.. | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L3500 Sun StorEdge L7 |
| 370-2847 | The /kernel/drv/st.conf file entries are incorrect in Solaris 2.5.1 and 2.6 for the DLT7000 drive. The use of an incorrect st.conf file entry will cause tape format incompatibility and poor device performance. In addition, the host system will not recognize the tape device as a DLT- 7000, but as a generic tape device and will assign improper tape density codes and device type to tape drive. Example shown below: The incorrect st.conf file entry is as follows: "Quantum DLT7000", "Quantum DLT7000", "DLT7k-data", DLT7k-data = 1,0x36,0,0x1D639,4,0x82,0x83,0x84,0x85,2; | Removable Media Sun StorEdge L1000 Sun StorEdge L3500 |
| 370-3516 | DLT 7000 drive Take-Up Leader and Cartridge Leader misalignment may cause the unit to fail. most of the reported problems in reference to the DLT7000 failures stem from the current firmware rev. (v72 or older) of the DLT7000 tape drive which does not allow the normal "Buckling Process" of the Take-Up Leader and Cartridge Leader to align properly and insure alignment of the Take-Up Leader and Cartridge Leader. A new DLT firmware version (v85 or newer) has been released that will correct many of the various failure conditions. | Sun StorEdge L1000 Sun StorEdge L3500 |
| 370-3516-01 | DLT 7000 drive Take-Up Leader and Cartridge Leader misalignment may cause the unit to fail. | Sun StorEdge L1000 |
| 370-3517 | Y-Axis 2-Phase Stepper Motor | Sun StorEdge L1000 |
| 370-3518 | X-Axis 2-Phase Stepper Motor | Sun StorEdge L1000 |
| 370-3519 | 24V, 41 CFM Fan | Sun StorEdge L1000 |
| 370-3520 | 24V, 90 CFM Fan | Sun StorEdge L1000 |
| 370-3521 | Differential Ultra/Wide SCSI Controller | Sun StorEdge L1000 |
| 370-3522 | X-Axis Timing Belt, 1/4" Wide | Sun StorEdge L1000 |
| 370-3523 | Y-Axis Timing Belt, 3/8" Wide | Sun StorEdge L1000 |
| 370-3524 | Right Front Door Assembly with Control Panel | Sun StorEdge L1000 |
| 370-3525 | Robotics Controller Board | Sun StorEdge L1000 |
| 370-3526 | Actuator Driver Board | Sun StorEdge L1000 |
| 370-3527 | Y-Encode Board | Sun StorEdge L1000 |
| 370-3528 | X-Motor Interconnect Board | Sun StorEdge L1000 |
| 370-3529 | Extension Axis Assembly | Sun StorEdge L1000 |
| 370-3530 | 8-Cartridge Bulk/Load Pack Assembly | Sun StorEdge L1000 |
| 370-3531 | Power Supply without Switch (-02: ATL p/n 6220571) | Sun StorEdge L1000 |
| 370-3532 | 5-Slot Backplane | Sun StorEdge L1000 |
| 370-3544 | 4 Packages of 99 Data Barcode Labels | Sun StorEdge L1000 Sun StorEdge L11000 |
| 370-3545 | External SCSI Cable, 90° HD68 to 90° HD68, 18 cm | Cables Data Cables by Type Cables External Data Cables by Type SCSI Sun StorEdge L1000 |
| 370-3546 | External SCSI Cable, 90° HD68 to 90° HD68, 36 cm | Cables Data Cables by Type Cables External Data Cables by Type SCSI Sun StorEdge L1000 |
| 370-3622 | Slide Rail | Sun StorEdge L1000 |
| 370-3627 | Left Single Fan with Bracket | Sun StorEdge L1000 |
| 370-3628 | Right Double Fan with Bracket | Sun StorEdge L1000 |
| 370-3629 | 1 Package of 33 Cleaning Tape Barcode | Sun StorEdge L1000 Sun StorEdge L11000 |
| 375-0006 | SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected. | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0119 | Dual Differential Ultra SCSI, cPCI (Use for DLT8000) | SCSI Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge A1000 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 |
| 380-0074 | Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000 | Sun StorEdge L1000 |
| 380-0075 | Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000 | Sun StorEdge L1000 |
| 380-0076 | Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000 | Sun StorEdge L1000 |
| 380-0077 | Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000 | Sun StorEdge L1000 |
| 380-0519 | Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000 | Sun StorEdge L1000 |
| 380-0520 | Rackmountable L1000 w 1 DLT Drive Rackmountable L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 7000 Drive Deskside L1000 w 4 DLT Drives Deskside L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT81-L1000 Rackmountable L1000 w 1 DLT 8000 Drive, Option SG-XLIBDLT8R-L1000 | Sun StorEdge L1000 |
| 380-0521 | DLT 8000 Tape Drive for L1000 | Sun StorEdge L1000 |
| 530-2352 | Expansion Cabinet, Option 9641 (two trays maximum) Tray Assembly #10-32 × 1/2" Screw (×16) Removable Storage Tray Rack Mount Bracket (×2) External SCSI Cable, HD68 to HD68, 4M | Cables Data Cables by Type Cables External Data Cables by Type Racks SCSI Sun StorEdge L1000 Sun StorEdge L11000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L280 Sun StorEdge L3500 Sun StorEdge S1 Systems Library Options ETL 4/1000 |
| 565-1477 | Service Kit with Tools, Manuals, and Diagnostics | Sun StorEdge L1000 |
| 595-3257 | 370-1704 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge L1000 Sun StorEdge L20 / L40 / L60 Sun StorEdge L3500 Sun StorEdge L9 Sun Ultra 2 |
| 595-4187 | 370-2443 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L9 Sun Ultra 2 |
| 595-4414 | 375-0006 [F] | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L9 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 595-4854 | 370-3516 [F] | Sun StorEdge L1000 |
| 595-5716 | 375-0119 [F] | Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge A1000 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L9 |
| 595-6224 | 380-0521 [F] | Sun StorEdge L1000 |
| 704-5684 | 6210160 6210151 0425003 6210150 6211266 None 6211222 6211221 6211223 6211224 | Sun StorEdge L1000 Sun StorEdge L180 Systems Library Options ETL 4/1000 |
| 704-6219 | Sun StorEdge L1000 Service CD-ROM Reference CD-ROM and LibMON[tm] 1.1 Patch | Sun StorEdge L1000 |
| 794-7575-01 | Networker may attempt to position a DLT7000 volume to read the label before the drive has completed the load sequence. The DLT7000 has a minimum load time of 48 seconds (previously written) this time may be longer if the tape is blank. The networker product has no understanding of the DLTs "time to load" or for that matter, any other tape library's "time to load" value, and may attempt to position the volume to read the label prior to the drive being at BOT. Should this be the case, one of the following errors may be returned during the mount request: tape: verify label operation in progress media warning:tape opening io error open error | Sun StorEdge L1000 Sun StorEdge L3500 |
| 798-0508-01 | Sun StorEdge LibMON 2.0 is currently supported on Solaris(TM) operating environment releases 2.5.1 and 2.6. Thus, customers wanting to run StorEdge LibMON/LibAgent 2.0 on Solaris 7 are unable to do so. In response to the above mentioned problem with StorEdge LibMON 2.0, patches 108014-01, 108015-01, 108016-01 and 108017-1 have been released to the SunSolve database. (9-23-99) | Sun StorEdge L1000 Sun StorEdge L3500 |
| 798-1365-01 | UPDATED FIN. StorEdge LibMON/LibAgent 2.0 does not provide support for L280 and L11000 libraries. | Sun StorEdge L1000 |
| 805-4822 | Sun StorEdge L1000 Unpacking Instructions Sun StorEdge L1000 User's Guide Control Panel Password Instructions | Sun StorEdge L1000 |
| 805-4823 | Sun StorEdge L1000 Unpacking Instructions Sun StorEdge L1000 User's Guide Control Panel Password Instructions | Sun StorEdge L1000 |
| 805-5577 | StorEdge L11000 Reference CD-ROM StorEdge L11000 Service CD-ROM Control Panel Password Instructions StorEdge L11000 Users Guide StorEdge L11000 Service Manual StorEdge L11000 Unpacking Instructions StorEdge L11000 Uncrating Instructions | Sun StorEdge L1000 Sun StorEdge L11000 |
| 855-5008-01 | Sun StorEdge LibMON 2.0 is currently supported on Solaris(TM) operating environment releases 2.5.1 and 2.6. Thus, customers wanting to run StorEdge LibMON/LibAgent 2.0 on Solaris 7 are unable to do so. In response to the above mentioned problem with StorEdge LibMON 2.0, patches 108014-01, 108015-01, 108016-01 and 108017-1 have been released to the SunSolve database. (9-23-99) | Sun StorEdge L1000 Sun StorEdge L3500 |
| X1062A | 370-1704 [F] | Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge L1000 Sun StorEdge L20 / L40 / L60 Sun StorEdge L3500 Sun StorEdge L9 Sun Ultra 2 |
| X1065A | 370-2443 [F] | SCSI Sun Enterprise 10000 Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun Ultra 2 |
| X3810A | 530-2352 [F] | Cables Data Cables by Type Cables External Data Cables by Type SCSI Sun StorEdge 3120 Sun StorEdge L1000 Sun StorEdge L3500 Sun StorEdge S1 |
| X6541A | SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected. | Allgemein / Unbekannt SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X6749A | 375-0119 [F] | SCSI Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 |