OSfOM

Parts for System: Sun StorEdge L20 / L40 / L60

<< Back to Systems Overview

Part NumberDescriptionAssociated Systems
150-1890Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68Cables Data Cables by Type
Cables External Data Cables by Type
Disk (external)
SCSI
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge N8200
Systems Disk Array Options RSM Array 2000 / StorEdge A3000
Systems Library Options ETL 4/1000
370-1704When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver.Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L20 / L40 / L60
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L9
Sun Ultra 2
370-2188Digital Linear Tape Compact IV cartridge, package of 10 (Option SG-XMEDDLTCIV-10)Removable Media
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Systems Library Options ETL 4/1000
Systems Library Options SPARCstorage DLT4700
370-2189Digital Linear Tape cleaning cartridges, package of 10 (Option SG-XMEDDLTCL-10)Removable Media
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Systems Library Options ETL 4/1000
Systems Library Options SPARCstorage DLT4700
370-2443When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver.SCSI
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun Ultra 2
370-4171Slave ControllerSun StorEdge L20 / L40 / L60
370-4172Vertical Lift AssemblySun StorEdge L20 / L40 / L60
370-4173DLT Empty Magazine (See part # 380-0516 for LTO Empty Magazine)Sun StorEdge L20 / L40 / L60
370-4174L20 Library Controller Assembly (370-4174-01) L20 Remote Mgmt Card (370-4175-02) L20 Picker/Translate Assembly (370-4177-01)Sun StorEdge L20 / L40 / L60
370-4174-01When replacing certain FRUs in a Sun StorEdge L20/L40/L60 Tape Library, failure to update the firmware may result in the tape library becoming non-functional. This problem is triggered by a firmware mismatch between different components in the library. The affected FRUs which may contain conflicting versions of firmware are: 370-4177-xx Picker/Translator Assembly 370-4174-xx Library Controller 370-4175-xx RMC (Remote Management Control) Card All three of these components must contain the same version of firmware. When a new FRU is installed with a different version, the library may display a "Partial-availability error" or "Firmware update needed" and there will appear to be a hardware problem. The library may be non-functional.Sun StorEdge L20 / L40 / L60
370-4175L20 Library Controller Assembly (370-4174-01) L20 Remote Mgmt Card (370-4175-02) L20 Picker/Translate Assembly (370-4177-01)Sun StorEdge L20 / L40 / L60
370-4175-02When replacing certain FRUs in a Sun StorEdge L20/L40/L60 Tape Library, failure to update the firmware may result in the tape library becoming non-functional. This problem is triggered by a firmware mismatch between different components in the library. The affected FRUs which may contain conflicting versions of firmware are: 370-4177-xx Picker/Translator Assembly 370-4174-xx Library Controller 370-4175-xx RMC (Remote Management Control) Card All three of these components must contain the same version of firmware. When a new FRU is installed with a different version, the library may display a "Partial-availability error" or "Firmware update needed" and there will appear to be a hardware problem. The library may be non-functional.Sun StorEdge L20 / L40 / L60
370-4176Display AssemblySun StorEdge L20 / L40 / L60
370-4177L20 Library Controller Assembly (370-4174-01) L20 Remote Mgmt Card (370-4175-02) L20 Picker/Translate Assembly (370-4177-01)Sun StorEdge L20 / L40 / L60
370-4177-01When replacing certain FRUs in a Sun StorEdge L20/L40/L60 Tape Library, failure to update the firmware may result in the tape library becoming non-functional. This problem is triggered by a firmware mismatch between different components in the library. The affected FRUs which may contain conflicting versions of firmware are: 370-4177-xx Picker/Translator Assembly 370-4174-xx Library Controller 370-4175-xx RMC (Remote Management Control) Card All three of these components must contain the same version of firmware. When a new FRU is installed with a different version, the library may display a "Partial-availability error" or "Firmware update needed" and there will appear to be a hardware problem. The library may be non-functional.Sun StorEdge L20 / L40 / L60
370-4178L20 / L40 / L60 Power SupplySun StorEdge L20 / L40 / L60
375-0006SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected.SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
375-0119Dual Differential Ultra SCSI, cPCI (Use for DLT8000)SCSI
Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
380-0321Deskside L20 with 1 DLT DriveSun StorEdge L20 / L40 / L60
380-0322Deskside L20 with 2 DLT DrivesSun StorEdge L20 / L40 / L60
380-0323Rackmountable L20 with 1 DLT DriveSun StorEdge L20 / L40 / L60
380-0324Rackmountable L20 with 2 DLT DrivesSun StorEdge L20 / L40 / L60
380-0325Deskside L40 with 2 DLT DrivesSun StorEdge L20 / L40 / L60
380-0326Rackmountable L40 with 2 DLT DrivesSun StorEdge L20 / L40 / L60
380-0327Rackmountable L60 with 4 DLT DrivesSun StorEdge L20 / L40 / L60
380-0346Quantum DLT 7000 HV Differential SCSI 35 - 70GB ( 390-0032 ) Tape DriveSun StorEdge L20 / L40 / L60
380-0383DLT[tm] 8000 HV Differential SCSI 40-80GB 1/2-Inch Tape Drive (HP C7202-80008)Sun StorEdge L20 / L40 / L60
Sun StorEdge L9
380-0383-01Under rare circumstances, DLT8000 drives with Cypress SRAMs are susceptible to silent data corruption and/or read errors. This may result in a customer restoring corrupted data leading to unpredictable system or application performance.Sun StorEdge L20 / L40 / L60
Sun StorEdge L9
380-0450Rack Mount Kit for L20 (Option SG-XRACKIT-L20)Sun StorEdge L20 / L40 / L60
380-0470Deskside L20 with 1 LTO DriveSun StorEdge L20 / L40 / L60
380-0471Deskside L20 with 2 LTO DrivesSun StorEdge L20 / L40 / L60
380-0472Rackmountable L20 with 1 LTO DriveSun StorEdge L20 / L40 / L60
380-0473Rackmountable L20 with 2 LTO DrivesSun StorEdge L20 / L40 / L60
380-0474Deskside L40 with 2 LTO DrivesSun StorEdge L20 / L40 / L60
380-0475Rackmountable L40 with 2 LTO DrivesSun StorEdge L20 / L40 / L60
380-0476Rackmountable L60 with 4 LTO DrivesSun StorEdge L20 / L40 / L60
380-0477LTO Drive - L20 LibrarySun StorEdge L20 / L40 / L60
380-0481LTO Drive Assembly (L9/L20)Sun StorEdge L20 / L40 / L60
Sun StorEdge L9
380-0484Chassis FanSun StorEdge L20 / L40 / L60
380-0485L20 Cable Set OEM, Main Harness Cable OEM, HVDS Older SCSI LP OEM, LVDS Older SCSI LP OEM, Display Cable OEM, Power Switch Cable OEM, IntrMod Con CableSun StorEdge L20 / L40 / L60
380-0486L20 Cable Set OEM, Main Harness Cable OEM, HVDS Older SCSI LP OEM, LVDS Older SCSI LP OEM, Display Cable OEM, Power Switch Cable OEM, IntrMod Con CableSun StorEdge L20 / L40 / L60
380-0487L20 Cable Set OEM, Main Harness Cable OEM, HVDS Older SCSI LP OEM, LVDS Older SCSI LP OEM, Display Cable OEM, Power Switch Cable OEM, IntrMod Con CableSun StorEdge L20 / L40 / L60
380-0488L20 Cable Set OEM, Main Harness Cable OEM, HVDS Older SCSI LP OEM, LVDS Older SCSI LP OEM, Display Cable OEM, Power Switch Cable OEM, IntrMod Con CableSun StorEdge L20 / L40 / L60
380-0489L20 Cable Set OEM, Main Harness Cable OEM, HVDS Older SCSI LP OEM, LVDS Older SCSI LP OEM, Display Cable OEM, Power Switch Cable OEM, IntrMod Con CableSun StorEdge L20 / L40 / L60
380-0490L20 Cable Set OEM, Main Harness Cable OEM, HVDS Older SCSI LP OEM, LVDS Older SCSI LP OEM, Display Cable OEM, Power Switch Cable OEM, IntrMod Con CableSun StorEdge L20 / L40 / L60
380-0491Left Magazine Lock AssemblySun StorEdge L20 / L40 / L60
380-0492Right magazine Lock AssemblySun StorEdge L20 / L40 / L60
380-0493Mailslot Solenoid AssemblySun StorEdge L20 / L40 / L60
380-0494SCSI Jumper Cable (HP C7210-61600)Cables Data Cables by Type
Cables External Data Cables by Type
Sun StorEdge L20 / L40 / L60
380-0495Wide Differential Terminator (HP A1658-62024)Cables Data Cables by Type
Cables External Data Cables by Type
Sun StorEdge L20 / L40 / L60
Sun StorEdge L9
380-0496L20 MotherboardSun StorEdge L20 / L40 / L60
380-0497L20 Cable Set OEM, Main Harness Cable OEM, HVDS Older SCSI LP OEM, LVDS Older SCSI LP OEM, Display Cable OEM, Power Switch Cable OEM, IntrMod Con CableSun StorEdge L20 / L40 / L60
380-0516LTO Empty Magazine (See part # 370-4173 for DLT Empty Magazine)Sun StorEdge L20 / L40 / L60
380-0517LTO Picker Translate Assembly (See part # 370-4177 for DLT Picker Translate Assembly)Sun StorEdge L20 / L40 / L60
390-0032380-0346Sun StorEdge L20 / L40 / L60
390-0089L9/L20 LTO 5 pack cleaning cartridges (Option SG-XMEDLTOHPCL-5)Sun StorEdge L20 / L40 / L60
530-1884Order Number SMC1000E-614-475 SPARCserver 1000E SPARCstorage Array (Single-Ended SCSI) 2.1GB 7200 RPM Disk Drive FRU Assembly SCSI Interconnect Board Assembly/FRU SCSI Interconnect Board SCSI Interconnect Daughter Board SWIS/S Option 1063 (×6) SunFastEthernet Option 1056 SunFastEthernet Option 1059 External SCSI Cable, HD68 to HD68, 80 cmCables Data Cables by Type
Cables External Data Cables by Type
Disk (external)
MediaCenter
Removable Media
SCSI
Sun Blade 100
Sun Blade 150
Sun Netra 150 / E150
Sun StorEdge A3500
Sun StorEdge L20 / L40 / L60
Sun Ultra 10
530-1885RSM with 3× Disk Drives per Tray RSM with 7× Disk Drives per Tray SPARCstorage RSM Chassis FRU 4.2GB 5400 RPM Disk Drive Assembly/FRU 4.2GB 7200 RPM Disk Drive Assembly/FRU 9.1GB 7200 RPM Disk Drive Assembly/FRU SPARCstorage RSM Shipping Bracket External SCSI Cable, HD68 to HD68, 2.0 M External SCSI Cable, HD68 to HD68, 12.0 M AC Power Cord, AMP Mate-N-Lok to IEC-320 Remote Keyswitch Control Cable, 3.2M AC Power Cord, AMP Mate-N-Lok to Y IEC-320Cables Data Cables by Type
Cables External Data Cables by Type
Disk (external)
Racks
SCSI
Sun Blade 100
Sun Blade 150
Sun SPARCstorage Array
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L500
Sun StorEdge L9
Sun Ultra 10
Systems Disk Array Options RSM Array 2000 / StorEdge A3000
Systems Disk Array Options StorEdge A3000 Rack
530-1886RSM with 3× Disk Drives per Tray RSM with 7× Disk Drives per Tray SPARCstorage RSM Chassis FRU 4.2GB 5400 RPM Disk Drive Assembly/FRU 4.2GB 7200 RPM Disk Drive Assembly/FRU 9.1GB 7200 RPM Disk Drive Assembly/FRU SPARCstorage RSM Shipping Bracket External SCSI Cable, HD68 to HD68, 2.0 M External SCSI Cable, HD68 to HD68, 12.0 M AC Power Cord, AMP Mate-N-Lok to IEC-320 Remote Keyswitch Control Cable, 3.2M AC Power Cord, AMP Mate-N-Lok to Y IEC-320Cables Data Cables by Type
Cables External Data Cables by Type
Disk (external)
SCSI
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L100 Tape Library
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25 Tape Library
Sun StorEdge L25/L100
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Systems Disk Array Options RSM Array 2000 / StorEdge A3000
Systems Disk Array Options StorEdge A3000 Rack
530-2352Expansion Cabinet, Option 9641 (two trays maximum) Tray Assembly #10-32 × 1/2" Screw (×16) Removable Storage Tray Rack Mount Bracket (×2) External SCSI Cable, HD68 to HD68, 4MCables Data Cables by Type
Cables External Data Cables by Type
Racks
SCSI
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge S1
Systems Library Options ETL 4/1000
530-2453SCSI RAID Controller SRC/P DPT PM3755U2B SmartRAID Millennium DPT DM4050-64 64MB DIMM DPT BB4050 Battery Backup Module DPT BP-0001-001 2.4V Battery DPT SX4055U2-2 SCSI Expansion Module External HD68 to VHDCI68 Cable, 2M (obsolete) External HD68 to VHDCI68 Cable, 2M * (-02 required) E450 Internal 8-Disk Backplane CableCables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun Fire V880
Sun StorEdge 3120
Sun StorEdge 3310
Sun StorEdge C4 Library
Sun StorEdge D2
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L8 Tape Autoloader
Sun StorEdge L9
Sun StorEdge S1
530-2455External SCSI Cable, HD68 to VHDC UltraSCSI, 10M (Option X3831A)Cables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun StorEdge 3120
Sun StorEdge 3310
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge C4 Library
Sun StorEdge L100 Tape Library
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25 Tape Library
Sun StorEdge L500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L8 Tape Autoloader
Sun StorEdge N8200
Sun StorEdge S1
595-2920530-1886 [F]Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L7
Sun StorEdge L9
595-3257370-1704 [F]Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge L1000
Sun StorEdge L20 / L40 / L60
Sun StorEdge L3500
Sun StorEdge L9
Sun Ultra 2
595-3503530-1884 [F]Sun Blade 100
Sun Blade 150
Sun StorEdge A3500
Sun StorEdge L20 / L40 / L60
Sun Ultra 10
595-3504530-1885 [F]Sun Blade 100
Sun Blade 150
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L9
Sun Ultra 10
595-4187370-2443 [F]Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L9
Sun Ultra 2
595-4414375-0006 [F]SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V480
Sun Fire V880
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
595-4693530-2453 [F]Sun StorEdge D2
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L9
Sun StorEdge S1
595-4695530-2455 [F]Sun StorEdge 3310
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L7
Sun StorEdge N8200
Sun StorEdge S1
595-5509380-0346 [F]Sun StorEdge L20 / L40 / L60
595-5716375-0119 [F]Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L9
595-6156380-0477Sun StorEdge L20 / L40 / L60
950-3746380-0383 [F]Sun StorEdge L20 / L40 / L60
Sun StorEdge L9
X1062A370-1704 [F]Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge L1000
Sun StorEdge L20 / L40 / L60
Sun StorEdge L3500
Sun StorEdge L9
Sun Ultra 2
X1065A370-2443 [F]SCSI
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun Ultra 2
X3831A530-2455 [F]Cables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun StorEdge 3120
Sun StorEdge 3310
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge C4 Library
Sun StorEdge L100 Tape Library
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25 Tape Library
Sun StorEdge L500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L8 Tape Autoloader
Sun StorEdge N8200
Sun StorEdge S1
Sun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
Sun StorageTek L500 Tape Library, RoHS:YL
X3832A530-2453 [F]Cables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun Fire V880
Sun StorEdge 3120
Sun StorEdge 3310
Sun StorEdge C4 Library
Sun StorEdge D2
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L8 Tape Autoloader
Sun StorEdge L9
Sun StorEdge S1
Sun StorageTek SL24 Tape Autoloader, RoHS:YL
Sun StorageTek SL48 Tape Library, RoHS:YL
X6541ASCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected.Allgemein / Unbekannt
SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
X6749A375-0119 [F]SCSI
Sun Fire 3800
Sun Fire 4800
Sun Fire 6800
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
X901A530-1884 [C] [S]Cables Data Cables by Type
Cables External Data Cables by Type
Sun Blade 100
Sun Blade 150
Sun StorEdge A3500
Sun StorEdge L20 / L40 / L60
Sun Ultra 10
X902A530-1885 [C] [S]Cables Data Cables by Type
Cables External Data Cables by Type
Sun Blade 100
Sun Blade 150
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L500
Sun StorEdge L9
Sun Ultra 10
X979A530-1886 [F] [S]Cables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L100 Tape Library
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25 Tape Library
Sun StorEdge L25/L100
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9