OSfOM

Parts for System: Sun StorEdge L3500

<< Back to Systems Overview

Part NumberDescriptionAssociated Systems
150-1890Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68Cables Data Cables by Type
Cables External Data Cables by Type
Disk (external)
SCSI
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge N8200
Systems Disk Array Options RSM Array 2000 / StorEdge A3000
Systems Library Options ETL 4/1000
300-1338ATL 326 Watt Power SupplyPower Supplies
Sun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
300-1339ATL 100 Watt Power SupplyPower Supplies
Sun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
300-1512ATL 100 Watt Power SupplySun StorEdge L3500
370-1703When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver.MediaCenter
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge S1
Sun Ultra 2
370-1704When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver.Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L20 / L40 / L60
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L9
Sun Ultra 2
370-2188Digital Linear Tape Compact IV cartridge, package of 10 (Option SG-XMEDDLTCIV-10)Removable Media
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Systems Library Options ETL 4/1000
Systems Library Options SPARCstorage DLT4700
370-2188-01The StorEdge DLT tape drives may encounter problems with swallowed or damaged leaders during the tape load or unloading process if faulty DLT cartridge tapes are in use. This FIN has been issued with the intent to assist Enterprise Services field personnel with the identification of defective DLT cartridge tapes which could cause damage to the StorEdge DLT tape drive.Sun StorEdge L1000
Sun StorEdge L3500
370-2189Digital Linear Tape cleaning cartridges, package of 10 (Option SG-XMEDDLTCL-10)Removable Media
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Systems Library Options ETL 4/1000
Systems Library Options SPARCstorage DLT4700
370-2189-01The StorEdge DLT tape drives may encounter problems with swallowed or damaged leaders during the tape load or unloading process if faulty DLT cartridge tapes are in use. This FIN has been issued with the intent to assist Enterprise Services field personnel with the identification of defective DLT cartridge tapes which could cause damage to the StorEdge DLT tape drive.Sun StorEdge L1000
Sun StorEdge L3500
370-2443When a SCSI bus reset is issued under heavy i/o, the isp driver causes the sd driver to report i/o errors. Any configuration with an isp driver version prior to the fix to bug 4280783 may be affected. The most likely configuration to experience this problem is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only), A1000, D1000 etc. connected to differential SCSI cards using the isp driver, or MultiPack, UniPack etc. connected to single-ended SCSI cards using the isp driver.SCSI
Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun Ultra 2
370-2443-01Intermittently, SCSI devices connected to a UDWIS card may not be usable after a reboot. This can prevent a system from booting if the UDWIS card connected to the boot device is affected. This problem is due to some issues in FCode versions less than 1.28 in the UDWIS card. When it is booting, the card fails to send a SCSI bus reset, or the SCSI bus reset is not held long enough to meet the SCSI specification, or the card fails to initialize correctly. This leads to the attached SCSI devices failing to negotiate correctly with the host.Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L3500
Sun StorEdge L7
370-2443-02Any system installed with a UDWIS/S (isp-fcode 1.28) has the possibility of displaying "invalid command" messages during POST, "probe-scsi-all" at the ok prompt, booting IF the variable "diag-switch?" is set to "true", or boot -hv from external storage..Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L3500
Sun StorEdge L7
370-2847The /kernel/drv/st.conf file entries are incorrect in Solaris 2.5.1 and 2.6 for the DLT7000 drive. The use of an incorrect st.conf file entry will cause tape format incompatibility and poor device performance. In addition, the host system will not recognize the tape device as a DLT- 7000, but as a generic tape device and will assign improper tape density codes and device type to tape drive. Example shown below: The incorrect st.conf file entry is as follows: "Quantum DLT7000", "Quantum DLT7000", "DLT7k-data", DLT7k-data = 1,0x36,0,0x1D639,4,0x82,0x83,0x84,0x85,2;Removable Media
Sun StorEdge L1000
Sun StorEdge L3500
370-2851Actuator Driver BoardSun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-2854X-Axis Interconnect BoardSun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-2855Y-Axis Stepper Motor AssemblySun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-2856X-Axis Stepper Motor AssemblySun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-2857Load Port Door Lockout SolenoidSun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-2858X-Axis Confirmation SensorSun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-2859Door Switch AssemblySun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-2860Y-Axis Umbilical CableSun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-2863Extension Axis Assembly (-02 required)Sun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-2866Fluorescent BulbSun StorEdge L180
Sun StorEdge L3500
Systems Library Options ETL 4/1000
370-3255Touch Panel Assembly (-02 or higher required)Sun StorEdge L180
Sun StorEdge L3500
370-32616210208 6210208 Unknown 0815033 6210509 6211630 6211003 UnknownSun StorEdge L180
Sun StorEdge L3500
370-32626210208 6210208 Unknown 0815033 6210509 6211630 6211003 UnknownSun StorEdge L180
Sun StorEdge L3500
370-3272DLT 7000 drive Take-Up Leader and Cartridge Leader misalignment may cause the unit to fail. most of the reported problems in reference to the DLT7000 failures stem from the current firmware rev. (v72 or older) of the DLT7000 tape drive which does not allow the normal "Buckling Process" of the Take-Up Leader and Cartridge Leader to align properly and insure alignment of the Take-Up Leader and Cartridge Leader. A new DLT firmware version (v85 or newer) has been released that will correct many of the various failure conditions.Removable Media
Sun StorEdge L180
Sun StorEdge L3500
370-3295Robotic Controller BoardSPARCstation LX
Sun StorEdge L3500
370-3296108 CFM Fan AssemblySun StorEdge L3500
370-3297Controller Electronics Assembly FanSun StorEdge L3500
370-3298Tape Drive Multiplexor BoardSun StorEdge L3500
370-3299Tape Drive Distribution BoardSun StorEdge L3500
370-3300X-Axis Umbilical CableSun StorEdge L3500
370-3304X-Axis Drive Belt, 240"Sun StorEdge L3500
370-3305Y-Axis Drive Belt, 188"Sun StorEdge L3500
370-3332DLT 7000 drive Take-Up Leader and Cartridge Leader misalignment may cause the unit to fail. most of the reported problems in reference to the DLT7000 failures stem from the current firmware rev. (v72 or older) of the DLT7000 tape drive which does not allow the normal "Buckling Process" of the Take-Up Leader and Cartridge Leader to align properly and insure alignment of the Take-Up Leader and Cartridge Leader. A new DLT firmware version (v85 or newer) has been released that will correct many of the various failure conditions.Removable Media
Sun StorEdge L180
Sun StorEdge L3500
370-3332-03L1800 Robotics firmware 2.34 L3500 Robotics firmware 2.40Sun StorEdge L3500
370-3516DLT 7000 drive Take-Up Leader and Cartridge Leader misalignment may cause the unit to fail. most of the reported problems in reference to the DLT7000 failures stem from the current firmware rev. (v72 or older) of the DLT7000 tape drive which does not allow the normal "Buckling Process" of the Take-Up Leader and Cartridge Leader to align properly and insure alignment of the Take-Up Leader and Cartridge Leader. A new DLT firmware version (v85 or newer) has been released that will correct many of the various failure conditions.Sun StorEdge L1000
Sun StorEdge L3500
370-3723DLT 7000 drive Take-Up Leader and Cartridge Leader misalignment may cause the unit to fail. most of the reported problems in reference to the DLT7000 failures stem from the current firmware rev. (v72 or older) of the DLT7000 tape drive which does not allow the normal "Buckling Process" of the Take-Up Leader and Cartridge Leader to align properly and insure alignment of the Take-Up Leader and Cartridge Leader. A new DLT firmware version (v85 or newer) has been released that will correct many of the various failure conditions.Sun StorEdge L11000
Sun StorEdge L3500
375-0006SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected.SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
530-2352Expansion Cabinet, Option 9641 (two trays maximum) Tray Assembly #10-32 × 1/2" Screw (×16) Removable Storage Tray Rack Mount Bracket (×2) External SCSI Cable, HD68 to HD68, 4MCables Data Cables by Type
Cables External Data Cables by Type
Racks
SCSI
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge S1
Systems Library Options ETL 4/1000
530-2515External SCSI Jumper Cable, HD68 to HD68Sun StorEdge L180
Sun StorEdge L3500
595-3257370-1704 [F]Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge L1000
Sun StorEdge L20 / L40 / L60
Sun StorEdge L3500
Sun StorEdge L9
Sun Ultra 2
595-4414375-0006 [F]SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V480
Sun Fire V880
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
595-4444ETL 2/3500 / StorEdge L3500 2 Drive Assembly ETL 7/3500 / StorEdge L3500 7 Drive AssemblySun StorEdge L3500
595-4445ETL 2/3500 / StorEdge L3500 2 Drive Assembly ETL 7/3500 / StorEdge L3500 7 Drive AssemblySun StorEdge L3500
595-4446370-3332 [F] *Sun StorEdge L3500
794-7575-01Networker may attempt to position a DLT7000 volume to read the label before the drive has completed the load sequence. The DLT7000 has a minimum load time of 48 seconds (previously written) this time may be longer if the tape is blank. The networker product has no understanding of the DLTs "time to load" or for that matter, any other tape library's "time to load" value, and may attempt to position the volume to read the label prior to the drive being at BOT. Should this be the case, one of the following errors may be returned during the mount request: tape: verify label operation in progress media warning:tape opening io error open errorSun StorEdge L1000
Sun StorEdge L3500
798-0508-01Sun StorEdge LibMON 2.0 is currently supported on Solaris(TM) operating environment releases 2.5.1 and 2.6. Thus, customers wanting to run StorEdge LibMON/LibAgent 2.0 on Solaris 7 are unable to do so. In response to the above mentioned problem with StorEdge LibMON 2.0, patches 108014-01, 108015-01, 108016-01 and 108017-1 have been released to the SunSolve database. (9-23-99)Sun StorEdge L1000
Sun StorEdge L3500
855-5008-01Sun StorEdge LibMON 2.0 is currently supported on Solaris(TM) operating environment releases 2.5.1 and 2.6. Thus, customers wanting to run StorEdge LibMON/LibAgent 2.0 on Solaris 7 are unable to do so. In response to the above mentioned problem with StorEdge LibMON 2.0, patches 108014-01, 108015-01, 108016-01 and 108017-1 have been released to the SunSolve database. (9-23-99)Sun StorEdge L1000
Sun StorEdge L3500
X1062A370-1704 [F]Sun Enterprise 10000
Sun Enterprise 3500
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge L1000
Sun StorEdge L20 / L40 / L60
Sun StorEdge L3500
Sun StorEdge L9
Sun Ultra 2
X3810A530-2352 [F]Cables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun StorEdge 3120
Sun StorEdge L1000
Sun StorEdge L3500
Sun StorEdge S1
X6063A370-3332 3 [F]Sun StorEdge L3500
X6073The two tape drive versions of the ETL 7/3500 and ETL 4/1800 are missing cables, which are needed to install additional drives (9/97).Sun StorEdge L3500
X6074The ATL 4/1800 and ATL 7/3500 have temperature sensors that are programmed by the vendor. Some units have been shipped with sensors that were not programmed (4/97).Sun StorEdge L3500
X6075The ATL 4/1800 and ATL 7/3500 have temperature sensors that are programmed by the vendor. Some units have been shipped with sensors that were not programmed (4/97).Sun StorEdge L3500
X6076The ATL 4/1800 and ATL 7/3500 have temperature sensors that are programmed by the vendor. Some units have been shipped with sensors that were not programmed (4/97).Sun StorEdge L3500
X6541ASCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected.Allgemein / Unbekannt
SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80