Part NumberDescriptionAssociated Systems
150-1890Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68Cables Data Cables by Type
Cables External Data Cables by Type
Disk (external)
SCSI
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L11000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L280
Sun StorEdge L3500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge N8200
Systems Disk Array Options RSM Array 2000 / StorEdge A3000
Systems Library Options ETL 4/1000
240-2690A1000/D1000 KeySun SPARC(R) Systems that have interlock switch feature.
Sun StorEdge A1000
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
250-1317540-2903 [F] 540-3366 530-2339 [F] 530-2340 [F] 530-2314 [F] 530-2363 [F] 501-4270 [F] 330-2058 530-2338 [F] 530-2337 [F] 330-2195 [F]Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 280R
Sun SPARC(R) Systems that have interlock switch feature.
Sun StorEdge N8200
Sun Ultra 45
300-1340360 Watt AC Input Power Supply 360 Watt DC Input Power Supply, Phoenix Connector 360 Watt DC Input Power Supply, Wago ConnectorPower Supplies
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
300-1449Lucent 380 Watt Power Supply (E220R)Power Supplies
Sun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
300-1455E220R DC-DC Converter Circuit DC-DC Converter Interposer BoardPower Supplies
Sun Enterprise 220R
Sun StorEdge N8200
330-1999Chassis Assembly without Covers, Medium Grey Chassis Assembly with Covers, Medium Grey Top and Bottom Cover, Medium Grey Side Cover, Medium Grey Cover Plug, Medium Grey Foot Backplane Drive Tray Assembly/FRU, Medium Grey Drive Tray Backplane Chassis Subassembly Chassis Power Supply Assembly/FRU, Medium Grey 440 Watt Power Supply Fan Tray Assembly/FRU, Medium Grey 120 × 38 mm Fan, 100CFMSun Enterprise 4000
Sun Enterprise 4500
Sun SPARCstorage Array
Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
330-2000Chassis Assembly without Covers, Medium Grey Chassis Assembly with Covers, Medium Grey Top and Bottom Cover, Medium Grey Side Cover, Medium Grey Cover Plug, Medium Grey Foot Backplane Drive Tray Assembly/FRU, Medium Grey Drive Tray Backplane Chassis Subassembly Chassis Power Supply Assembly/FRU, Medium Grey 440 Watt Power Supply Fan Tray Assembly/FRU, Medium Grey 120 × 38 mm Fan, 100CFMCommunication
Sun Enterprise 4000
Sun Enterprise 4500
Sun SPARCstorage Array
Sun StorEdge A1000
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
330-2266Vented Side PanelSun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
330-2267Bottom CoverSun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
330-2270Door Frame (A1000)Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
330-2400Enclosure Assembly RMA Bezel Floppy Filler Panel Curved Bezel 4U Trim Strip Enclosure Assembly with System BoardSun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Fire 280R
Sun Fire V880
Sun Fire V890
Sun StorEdge N8200
330-2535Top CoverSun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
330-2805Enclosure Assembly with System Board Processor Module Slot Filler Panel System Board Shroud Assembly / CPU Card Cage System Board Airguide Assembly Enclosure AssemblySun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
Sun Ultra 80
330-2911Enclosure Assembly RMA Bezel Floppy Filler Panel Curved Bezel 4U Trim Strip Enclosure Assembly with System BoardSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-4288StorEdge D240 Center FRU 12-Slot A1000/D1000 FRU w 1" Bracket 540-3024 w Plate 340-4288 or 340-6640 or Plate 340-5928 or 340-7269Disk (internal)
Disks by Part Number
Sun Enterprise 10000
Sun Enterprise 3500
Sun Fire E2900
Sun Fire V120
Sun Netra 120
Sun Netra st D130
Sun Netra st D130 Disk
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
T3
340-4469Option X9653A Rack Mount Kit Universal Rack Bracket (×2) Tray #10-32 × 1/2" Screw (×16) 10×14×.04375 Screw (×4)Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
340-4470A1000/D1000 Rack Mounting Bracket (×2) A1000/D1000 Right Clamp A1000/D1000 Left ClampSun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
340-4471A1000/D1000 Rack Mounting Bracket (×2) A1000/D1000 Right Clamp A1000/D1000 Left ClampRacks
Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
340-4472A1000/D1000 Rack Mounting Bracket (×2) A1000/D1000 Right Clamp A1000/D1000 Left ClampRacks
Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
340-5827Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-5830Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-5831Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet Rear Panel AC Line Filter AC Power Cable AC Ground Cable Ultra 60 System Board Mounting Tray Chassis Assembly Base Enclosure Disk Drive Bay Front Enclosure Top Cover Front Enclosure Power Bay CoverSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-5834Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-5883Rail Kit Assembly Short Rack Mounting Bracket (540-2625-01) Long Rack Mounting Bracket (540-2625-01) Outer Slide Rail (540-2625-01) Mounting Bracket + Rail (540-2625-02)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-5928Netra ct/st/CT/T1/120 FRU NEBS Level 2/3 w 1" Bracket 540-3024 w Plate 340-4288 or Plate 340-6640 or Plate 340-5928 or Plate 340-7269Disk (internal)
Disks by Part Number
Sun Enterprise 10000
Sun Enterprise 3500
Sun Fire 280R
Sun Fire E2900
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V250 Server
Sun Netra 120
Sun Netra 1280 Server
Sun Netra 240 Server
Sun Netra 440 Server
Sun Netra st D130
Sun Netra st D130 Disk
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun StorEdge S1
T3
340-5996Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-6001Enclosure Assembly Fan Tray with 3× 120 mm Fans Fan Tray, Option 9820 (replaced 540-4434 10/01) Power Supply Filler Panel Security Switch Lock DC Power Signal Cable DC Power Cable Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable FC-AL and RMA Power Cable (-04 required) FC-AL Cable 8-Bit SCSI Cable I 2 C Cable Control CableSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-6118Enclosure Assembly Fan Tray with 3× 120 mm Fans Fan Tray, Option 9820 (replaced 540-4434 10/01) Power Supply Filler Panel Security Switch Lock DC Power Signal Cable DC Power Cable Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable FC-AL and RMA Power Cable (-04 required) FC-AL Cable 8-Bit SCSI Cable I 2 C Cable Control CableSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-6124Rail Kit Assembly Short Rack Mounting Bracket (540-2625-01) Long Rack Mounting Bracket (540-2625-01) Outer Slide Rail (540-2625-01) Mounting Bracket + Rail (540-2625-02)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-6125Rail Kit Assembly Short Rack Mounting Bracket (540-2625-01) Long Rack Mounting Bracket (540-2625-01) Outer Slide Rail (540-2625-01) Mounting Bracket + Rail (540-2625-02)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun Fire V100
Sun StorEdge N8200
340-6131Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
340-6640StorEdge D240 Center FRU 12-Slot A1000/D1000 FRU w 1" Bracket 540-3024 w Plate 340-4288 or 340-6640 or Plate 340-5928 or 340-7269Disk (internal)
Disks by Part Number
Sun Blade 1000
Sun Blade 2000
Sun Enterprise 10000
Sun Enterprise 3500
Sun Fire 280R
Sun Fire E2900
Sun Fire V120
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 120
Sun Netra 20
Sun Netra st D130
Sun Netra st D130 Disk
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
T3
340-7269Netra ct/st/CT/T1/120 FRU NEBS Level 2/3 w 1" Bracket 540-3024 w Plate 340-4288 or Plate 340-6640 or Plate 340-5928 or Plate 340-7269Disk (internal)
Disks by Part Number
Sun Blade 1000
Sun Blade 2000
Sun Enterprise 10000
Sun Enterprise 3500
Sun Fire 280R
Sun Fire E2900
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V250 Server
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 120
Sun Netra 1280 Server
Sun Netra 20
Sun Netra 240 Server
Sun Netra 440 Server
Sun Netra st D130
Sun Netra st D130 Disk
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge A5000
Sun StorEdge A5100
Sun StorEdge A5200
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun StorEdge S1
T3
370-2439Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68Memory
SCSI
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge N8200
Systems Disk Array Options RSM Array 2000 / StorEdge A3000
370-3290Empty 1.0" Disk Drive Slot FillerSun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
370-3416SunSolve CDs may experience read errors on Toshiba XM-6201B 32x drives.Removable Media
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun StorEdge N8200
Sun Ultra 2
370-3417Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68SCSI
Sun StorEdge A1000
Sun StorEdge N8200
Sun Storage[TM] Array Battery Life Cycle
370-3553Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68Memory
SCSI
Sun StorEdge A1000
Sun StorEdge N8200
370-4099Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet Rear Panel AC Line Filter AC Power Cable AC Ground Cable Ultra 60 System Board Mounting Tray Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
375-0006SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected.SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
375-0015Raid Controller FRU w/o Battery, 16MB MPU + 64MB RPA Raid Controller FRU w/o Battery, 8MB MPU + 16MB RPA Raid Controller with 8MB MPU + 16MB RPA + Battery Battery Module 4MB Memory Module 1M×36 8MB Memory Module 2M×36 32MB Memory Module 8M×36 (discontinued 2/98) 32MB Memory Module 8M×36 D1000 Differential SCSI Board D1000 Differential Terminator, HD68SCSI
Sun StorEdge A1000
Sun StorEdge N8200
375-0094E220R DC-DC Converter Circuit DC-DC Converter Interposer BoardPower Supplies
Sun Enterprise 220R
Sun StorEdge N8200
375-0136Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller, 8MB MPU + 16MB RPA w/ Battery Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery BatterySun StorEdge A1000
Sun StorEdge N8200
390-000218.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LCDisk (external)
Disks by Part Number
SCSI
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire V120
Sun Netra 120
Sun Netra st D130
Sun Netra st D130 Disk
Sun Netra t 1400
Sun Netra t 1400/1405 Disks
Sun Netra t 1405 Server
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
T3
390-000636.4 GB Wide SCSI Disk Card with 2× 18.2GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 18.2GB 10000 RPM Disk Drive FRU 18.2GB Disk Drive, Seagate ST318203LC 18.2GB Disk Drive, Fujitsu MAG3182LC 18.2GB Disk Drive, Seagate ST318404LC 18.2GB Disk Drive, Fujitsu MAJ3182MCDisk (internal)
Disks by Part Number
SCSI
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Netra t 1400
Sun Netra t 1400/1405 Disks
Sun Netra t 1405 Server
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
390-0025System Control Peripheral Assembly System Control Peripheral Board FRU Drive Kit [ Note 1 ] ATAPI to SCSI Adapter Bracket ATAPI to SCSI Adapter 10X SCSI DVD-ROM, Medium Grey 10X ATAPI DVD-ROM [ Notes 2, 3 ] 10X ATAPI DVD-ROM, [ Notes 2, 3, 5 ] 20-40GB 4 mm DDS-4 Tape Drive, Medium Grey [ Note 4 ] 36-72GB 4 mm DAT 72 Tape Drive 73.4GB 10000 RPM Disk, Seagate ST373307LC 73.4GB 10000 RPM Disk, Hitachi DK32EJ-72NC 73.4GB 10000 RPM Disk, Fujitsu MAP3735NC 73.4GB 10000 RPM Disk, Seagate ST373207LC 73.4GB 10000 RPM Disk, Fujitsu MAT3073NC 73.4GB 10000 RPM Disk, Hitachi HUS103073A 73.4GB 10000 RPM Disk, Fujitsu MAW3073NC, 73.4GB 10000 RPM Disk, Hitachi HUS103073A, 73.4GB 10000 RPM Disk, Seagate ST373027LC, Internal Peripheral Power Cable Internal SCSI DVD-ROM Cable Internal ATAPI DVD-ROM Power Cable Internal ATAPI DVD-ROM Power Cable, [ Note 5 ]Racks
Removable Media
Sun Blade 1000
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire E25K
Sun Fire V880
Sun Netra 20
Sun StorEdge D2
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
Systems Telco Netra t 1120
Systems Telco Netra t 1125
390-003818.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LCDisk (external)
Disks by Part Number
SCSI
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 15K
Sun Fire V120
Sun Netra st D130 Disk
Sun Netra t 1400
Sun Netra t 1400/1405 Disks
Sun Netra t 1405 Server
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
T3
390-004336.4 GB Wide SCSI Disk Card with 2× 18.2GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 18.2GB 10000 RPM Disk Drive FRU 18.2GB Disk Drive, Seagate ST318203LC 18.2GB Disk Drive, Fujitsu MAG3182LC 18.2GB Disk Drive, Seagate ST318404LC 18.2GB Disk Drive, Fujitsu MAJ3182MCDisk (internal)
Disks by Part Number
SCSI
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 15K
Sun Fire V120
Sun Netra 120
Sun Netra st D130
Sun Netra st D130 Disk
Sun Netra t 1400
Sun Netra t 1400/1405 Disks
Sun Netra t 1405 Server
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
390-0048IBM DDYS-T18350 [DDYST1835SUN18G] (18.2GB - 10000 RPM - SCSI Disk)Disk (internal)
Disks by Part Number
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire V120
Sun Netra 120
Sun Netra st D130
Sun Netra st D130 Disk
Sun Netra t 1400
Sun Netra t 1400/1405 Disks
Sun Netra t 1405 Server
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
390-006018.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LCDisk (external)
Disk (internal)
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire V120
Sun Netra st D130 Disk
Sun Netra t 1400/1405 Disks
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
390-0066Fujitsu MAN3184MC [MAN3184M SUN18G] (18.2GB - 10000 RPM - SCSI Disk)Disk (internal)
Disks by Part Number
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Netra t 1400
Sun Netra t 1400/1405 Disks
Sun Netra t 1405 Server
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun StorEdge S1
Sun Ultra 60
Sun Ultra 80
390-008518.2GB 7200 RPM Disk, Fujitsu MAA3182SC 18.2GB 7200 RPM Disk, Seagate ST118273LC 18.2GB 10000 RPM Disk, Seagate ST318203LC 18.2GB 10000 RPM Disk, Seagate ST318404LC 18.2GB 10000 RPM Disk, Fujitsu MAJ3182MC 18.2GB 10000 RPM Disk, Seagate ST318305LC 36.4GB 10000 RPM Disk, Seagate ST336704LC 36.4GB 10000 RPM Disk, Fujitsu MAJ3364MC 36.4GB 10000 RPM Disk, Seagate ST336605LC 36.4GB 10000 RPM Disk, Seagate ST336607LCDisk (external)
Disks by Part Number
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 15K
Sun Fire V120
Sun Netra 120
Sun Netra st D130
Sun Netra st D130 Disk
Sun Netra t 1400
Sun Netra t 1400/1405 Disks
Sun Netra t 1405 Server
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun StorEdge S1
Sun Ultra 60
Sun Ultra 80
T3
501-313664MB SIMM 32MB SIMM 128MB SIMM 64MB SIMMMemory
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 450
Sun StorEdge N8200
Sun Ultra 1
Sun Ultra 2
Sun Ultra 30
Sun Ultra 60
Systems Telco Netra t 1120
Systems Telco Netra t 1125
501-4366Sun Quad FastEthernet Sun Quad FastEthernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4MEthernet
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V480
Sun Fire V880
Sun Netra 20
Sun Netra t1
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
501-4373GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15MEthernet
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 60
Sun Ultra 80
501-5344450MHz UltraSPARC II Module 4MB Cache Sapphire-BlackSun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
501-5406Sun Quad FastEthernet Sun Quad FastEthernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4MEthernet
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
501-55052-Slot SCSI Disk BackplaneSun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
501-5506DC Power Distribution Board (E220R)Power Supplies
Sun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
501-5539450MHz UltraSPARC II Module 4MB Cache Sapphire-Black/BlazeSun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
501-5687450MHz UltraSPARC II Module 4MB Cache Sapphire-Black/BlazeSun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
501-6071450MHz UltraSPARC II Module 4MB Cache Sapphire-Black/BlazeSun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
525-1430U2006 U2006 U13 U13 U13 U13 U2706 U2706 U2706 U3104 U3008 U48 U48 U2101 J3601 SCCR SCCR SCCR U25 SCCR U25 SCCR U25 SCCR U2101 U2101 U1804 U4618 U0205 U2501 U2106 ID BoardIDPROM
Sun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
Systems Telco Netra t 1120
Systems Telco Netra t 1125
525-1701-13OBP 3.23 Version 1 + POST 2.0.2 + OBDIAG 1.3Boot PROMs
Sun StorEdge N8200
Sun-4u Architecture
530-2454External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 4MCables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun StorEdge 3120
Sun StorEdge 3310
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge C4 Library
Sun StorEdge L100 Tape Library
Sun StorEdge L25 Tape Library
Sun StorEdge L8 Tape Autoloader
Sun StorEdge N8200
Sun StorEdge S1
530-2455External SCSI Cable, HD68 to VHDC UltraSCSI, 10M (Option X3831A)Cables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun StorEdge 3120
Sun StorEdge 3310
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge C4 Library
Sun StorEdge L100 Tape Library
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25 Tape Library
Sun StorEdge L500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L8 Tape Autoloader
Sun StorEdge N8200
Sun StorEdge S1
530-2819Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
530-2824Enclosure Assembly Fan Tray with 3× 120 mm Fans Fan Tray, Option 9820 (replaced 540-4434 10/01) Power Supply Filler Panel Security Switch Lock DC Power Signal Cable DC Power Cable Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable FC-AL and RMA Power Cable (-04 required) FC-AL Cable 8-Bit SCSI Cable I 2 C Cable Control CableSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
530-2826Enclosure Assembly Fan Tray with 3× 120 mm Fans Fan Tray, Option 9820 (replaced 540-4434 10/01) Power Supply Filler Panel Security Switch Lock DC Power Signal Cable DC Power Cable Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable FC-AL and RMA Power Cable (-04 required) FC-AL Cable 8-Bit SCSI Cable I 2 C Cable Control CableSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
530-2827Enclosure Assembly Fan Tray with 3× 120 mm Fans (obsolete) Fan Tray with 3× 120 mm Fans Fan Tray with 3× 120 mm Fans, Option 9820 Power Supply Filler Panel Security Switch Lock Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable SCSI Cable DC Power Cable DC Power Signal Cable Control Cable I/O Power Cable Chassis AssemblySun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
530-2828Enclosure Assembly Fan Tray with 3× 120 mm Fans (obsolete) Fan Tray with 3× 120 mm Fans Fan Tray with 3× 120 mm Fans, Option 9820 Power Supply Filler Panel Security Switch Lock Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable SCSI Cable DC Power Cable DC Power Signal Cable Control Cable I/O Power Cable Chassis AssemblySun Enterprise 220R
Sun StorEdge N8200
530-2829Enclosure Assembly Fan Tray with 3× 120 mm Fans (obsolete) Fan Tray with 3× 120 mm Fans Fan Tray with 3× 120 mm Fans, Option 9820 Power Supply Filler Panel Security Switch Lock Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable SCSI Cable DC Power Cable DC Power Signal Cable Control Cable I/O Power Cable Chassis AssemblySun Enterprise 220R
Sun StorEdge N8200
530-2830Enclosure Assembly Fan Tray with 3× 120 mm Fans Fan Tray, Option 9820 (replaced 540-4434 10/01) Power Supply Filler Panel Security Switch Lock DC Power Signal Cable DC Power Cable Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable FC-AL and RMA Power Cable (-04 required) FC-AL Cable 8-Bit SCSI Cable I 2 C Cable Control CableSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
530-2861Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
530-2864Enclosure Assembly Fan Tray with 3× 120 mm Fans Fan Tray, Option 9820 (replaced 540-4434 10/01) Power Supply Filler Panel Security Switch Lock DC Power Signal Cable DC Power Cable Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable FC-AL and RMA Power Cable (-04 required) FC-AL Cable 8-Bit SCSI Cable I 2 C Cable Control CableSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
530-2947Null Modem Cable DB25 M/M, 10 Ft.Sun StorEdge N8200
540-3024Ultra 1, Ultra 2 Ultra 30, Ultra 60, Ultra 80 E250, E450, E220R, E420R Sun Blade 1000 E150, nfs 150, i 150 MultiPack, E3000, E3500 A1000, D1000, A3500 A5000, A5100, A5200, A7000 Netra ct 400, Netra ct 800 st D130, st A1000, st D1000Disk (external)
Disk (internal)
Disk Spud Bracket
Disks by Part Number
Sun Blade 1000
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 280R
Sun Fire E2900
Sun Fire E2900, RoHS:YL
Sun Fire V120
Sun Fire V125
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V250 Server
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 120
Sun Netra 1280 Server
Sun Netra 1280 Server, RoHS:YL
Sun Netra 1290, RoHS:YL
Sun Netra 20
Sun Netra 240 Server
Sun Netra 240 Server, RoHS:YL
Sun Netra 440 Server
Sun Netra 440 Server, RoHS:YL
Sun Netra st D130
Sun Netra st D130 Disk
Sun Netra t 1400
Sun Netra t 1400/1405 Disks
Sun Netra t 1405 Server
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge A5200
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
Sun StorEdge S1
Sun Ultra 2
Sun Ultra 30
Sun Ultra 60
Sun Ultra 80
T3
540-3269Empty 12-Drive Chassis Assembly Empty 8-Drive Chassis Assembly Empty Chassis Assembly Empty 8-Drive Chassis with Rack Mount TraySun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
540-3323Fan CanisterSun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
540-3324Front Door Assembly (-01 w Frame, -02 without Frame)Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
540-3325Empty 12-Drive Chassis Assembly Empty 8-Drive Chassis Assembly Empty Chassis Assembly Empty 8-Drive Chassis with Rack Mount TraySun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
540-4169Enclosure Assembly Fan Tray with 3× 120 mm Fans (obsolete) Fan Tray with 3× 120 mm Fans Fan Tray with 3× 120 mm Fans, Option 9820 Power Supply Filler Panel Security Switch Lock Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable SCSI Cable DC Power Cable DC Power Signal Cable Control Cable I/O Power Cable Chassis AssemblySun Enterprise 220R
Sun StorEdge N8200
540-4178Empty 1.0" Disk Drive Slot Filler 9.1GB 10000 RPM Disk Drive FRU, NEBS Level 3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3Disk (internal)
Disks by Part Number
Sun Enterprise 10000
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge D2
Sun StorEdge N8200
T3
540-4185Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet Rear Panel AC Line Filter AC Power Cable AC Ground Cable Ultra 60 System Board Mounting Tray Chassis Assembly Base Enclosure Disk Drive Bay Front Enclosure Top Cover Front Enclosure Power Bay CoverSun StorEdge N8200
540-4186Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
540-4188Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
540-4219Enclosure Assembly RMA Bezel Floppy Filler Panel Curved Bezel 4U Trim Strip Enclosure Assembly with System BoardSun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
540-4230Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
540-4231Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet Rear Panel AC Line Filter AC Power Cable AC Ground Cable Ultra 60 System Board Mounting Tray Chassis Assembly Base Enclosure Disk Drive Bay Front Enclosure Top Cover Front Enclosure Power Bay CoverSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
540-4232Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
540-4251Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet Rear Panel AC Line Filter AC Power Cable AC Ground Cable Ultra 60 System Board Mounting Tray Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun StorEdge N8200
540-4253Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet to Power Supply Rear Panel Sun Blade 1000 System Board Mounting Panel 10A AC Receptacle and Line Filter AC Power Cable AC Ground Cable Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
540-4282Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet Rear Panel AC Line Filter AC Power Cable AC Ground Cable Ultra 60 System Board Mounting Tray Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun StorEdge N8200
540-4283Chassis Assembly Left Door Rear Enclosure Top Cover Inner Slide Rail Right Door Media Drive Mounting Assembly Power Distribution Board Cover AC Outlet Rear Panel AC Line Filter AC Power Cable AC Ground Cable Ultra 60 System Board Mounting Tray Chassis Assembly (replaced 540-4231) Base Enclosure Disk Drive Bay Front Top Cover (replaced 340-5831) Front Enclosure Power Bay Cover (replaced 340-5973)Sun Enterprise 220R
Sun StorEdge N8200
540-4284Enclosure Assembly Fan Tray with 3× 120 mm Fans (obsolete) Fan Tray with 3× 120 mm Fans Fan Tray with 3× 120 mm Fans, Option 9820 Power Supply Filler Panel Security Switch Lock Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable SCSI Cable DC Power Cable DC Power Signal Cable Control Cable I/O Power Cable Chassis AssemblySun Enterprise 220R
Sun StorEdge N8200
540-4315Enclosure Assembly RMA Bezel Floppy Filler Panel Curved Bezel 4U Trim Strip Enclosure Assembly with System BoardSun StorEdge N8200
540-4316Enclosure Assembly with System Board Processor Module Slot Filler Panel Processor Module Cardcage Assembly Airguide Assembly Enclosure AssemblySun Enterprise 220R
Sun StorEdge N8200
540-4327Enclosure Assembly with System Board Processor Module Slot Filler Panel Processor Module Cardcage Assembly Airguide Assembly Enclosure AssemblySun Enterprise 220R
Sun StorEdge N8200
540-4329Enclosure Assembly with System Board Processor Module Slot Filler Panel Processor Module Cardcage Assembly Airguide Assembly Enclosure AssemblySun Enterprise 220R
Sun StorEdge N8200
540-4434Enclosure Assembly Fan Tray with 3× 120 mm Fans Fan Tray, Option 9820 (replaced 540-4434 10/01) Power Supply Filler Panel Security Switch Lock DC Power Signal Cable DC Power Cable Keyswitch/LED/Power Cable FRU Assembly Keyswitch/LED/Power Cable RMA 8-Bit SCSI Cable FC-AL and RMA Power Cable (-04 required) FC-AL Cable 8-Bit SCSI Cable I 2 C Cable Control CableSun Enterprise 220R
Sun Enterprise 420R
Sun Fire 280R
Sun StorEdge N8200
595-3813501-3136 [F] (128MB)Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 450
Sun StorEdge N8200
Sun Ultra 2
Sun Ultra 30
Sun Ultra 60
595-3906Option X9653A Rack Mount Kit Universal Rack Bracket (×2) Tray #10-32 × 1/2" Screw (×16) 10×14×.04375 Screw (×4)Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
595-4414375-0006 [F]SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V480
Sun Fire V880
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
595-4694530-2454 [F]Sun StorEdge 3310
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
Sun StorEdge S1
595-4695530-2455 [F]Sun StorEdge 3310
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L7
Sun StorEdge N8200
Sun StorEdge S1
595-5199540-4178 [F] Spud Bracket FRU w/ 1" Bracket 540-3024 w/ Plate 340-4288 or 340-6640 or 340-5928 or 340-7269Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
595-5220501-6071 [F] *Sun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
595-5291300-1449 [F]Sun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
595-5558390-0025 [F]Removable Media
Sun Blade 1000
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 280R
Sun Fire V880
Sun Netra 20
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
599-2330Enclosure Assembly RMA Bezel Floppy Filler Panel Curved Bezel 4U Trim Strip Enclosure Assembly with System BoardSun Enterprise 220R
Sun StorEdge N8200
605-1594501-5406 [F]Ethernet
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V480
Sun Fire V880
Sun Netra 20
Sun Netra t1
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
605-1601501-4373 [F]Ethernet
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 2000
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire V120
Sun Fire V480
Sun Fire V880
Sun Netra 20
Sun Netra t1
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 60
Sun Ultra 80
806-4668Sun StorEdge N8200 Filer Release NotesSun StorEdge N8200
806-4669Sun StorEdge N8400 and N8600 Filer Business ExampleN8400/N8600 Configuration Information
Sun StorEdge N8200
X1034A501-5406 [F]Ethernet
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
X1141AAdapter boards capable of 66MHz operation may only run at 33MHz when installed into 66MHz PCI I/O slots on Sun Fire 12K/15K platforms.Ethernet
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 10000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 3500
Sun Enterprise 420R
Sun Enterprise 450
Sun Enterprise 4500
Sun Enterprise 5500
Sun Enterprise 6500
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire V120
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 60
Sun Ultra 80
X1195A501-6071 [F]Sun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
X3830A530-2454 [F]Cables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun StorEdge 3120
Sun StorEdge 3310
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge C4 Library
Sun StorEdge L100 Tape Library
Sun StorEdge L25 Tape Library
Sun StorEdge L8 Tape Autoloader
Sun StorEdge N8200
Sun StorEdge S1
Sun StorageTek SL24 Tape Autoloader, RoHS:YL
Sun StorageTek SL48 Tape Library, RoHS:YL
X3831A530-2455 [F]Cables Data Cables by Type
Cables External Data Cables by Type
SCSI
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun StorEdge 3120
Sun StorEdge 3310
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge C4 Library
Sun StorEdge L100 Tape Library
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25 Tape Library
Sun StorEdge L500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L8 Tape Autoloader
Sun StorEdge N8200
Sun StorEdge S1
Sun StorageTek L500 Tape Library (Mixed Media), RoHS:YL
Sun StorageTek L500 Tape Library, RoHS:YL
X5238A540-4178 [F]Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
X6168A390-0025 [C]Removable Media
Sun Blade 1000
Sun Blade 2000
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 280R
Sun Fire V880
Sun Netra 20
Sun StorEdge N8200
Sun Ultra 60
Sun Ultra 80
X6541ASCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected.Allgemein / Unbekannt
SCSI
Sun Blade 100
Sun Blade 1000
Sun Blade 150
Sun Blade 1500
Sun Blade 2000
Sun Blade 2500
Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 420R
Sun Enterprise 450
Sun Fire 12K / 15K
Sun Fire 280R
Sun Fire 4800
Sun Fire 6800
Sun Fire E25K
Sun Fire V120
Sun Fire V1280
Sun Fire V210
Sun Fire V240
Sun Fire V440
Sun Fire V480
Sun Fire V490
Sun Fire V880
Sun Fire V890
Sun Netra 20
Sun Netra t1
Sun StorEdge A1000
Sun StorEdge A3500
Sun StorEdge Array Controller D1000
Sun StorEdge L1000
Sun StorEdge L180
Sun StorEdge L20 / L40 / L60
Sun StorEdge L25/L100
Sun StorEdge L3500
Sun StorEdge L5500
Sun StorEdge L7
Sun StorEdge L700
Sun StorEdge L9
Sun StorEdge N8200
Sun Ultra 10
Sun Ultra 30
Sun Ultra 5
Sun Ultra 60
Sun Ultra 80
X7004A501-3136 [F]Sun Enterprise 220R
Sun Enterprise 250
Sun Enterprise 450
Sun StorEdge N8200
Sun Ultra 2
Sun Ultra 30
Sun Ultra 60
X7040A370-2439 [F] prior to 3/98Sun StorEdge A1000
Sun StorEdge N8200
X9653AA small quantity of A1000/D1000 rackmount kits (X9653A) have been recently shipped to customer sites with an insufficient amount of screws needed to properly complete the rackmount installation. The affected rackmount kits (X9653A) shipped with four (4) installation screws as opposed to the twenty (20) screws that are needed for the installation. In addition, the Sun StorEdge A1000/D1000 rackmount installation manual (805-2626-10) incorrectly illustrates that only four (4) screws are needed to complete the A1000/D1000 rackmount installa- tion.Sun StorEdge A1000
Sun StorEdge Array Controller D1000
Sun StorEdge N8200
X9684A300-1449 [F]Sun Enterprise 220R
Sun Enterprise 420R
Sun StorEdge N8200