Parts for System: Sun Ultra 30
| Part Number | Description | Associated Systems |
|---|---|---|
| 240-2711 | M3 × 6 mm Screw | Sun Ultra 30 Sun Ultra 60 |
| 240-2714 | M3 × 10 mm Screw | Sun Ultra 30 Sun Ultra 60 |
| 240-2750 | PCI Filler Panel Audio Module Filler Panel | Sun Blade 1000 Sun Blade 2000 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 300-1325 | Lucent LP300A 300 Watt Power Supply (Pre-FCS) Lucent LP300A 300 Watt Power Supply (A116) | Power Supplies Sun Ultra 30 |
| 300-1337 | Lucent LP300A 300 Watt Power Supply (Pre-FCS) Lucent LP300A 300 Watt Power Supply (A116) | Power Supplies Sun Ultra 30 |
| 300-1343 | Zytec EP071295-C 350 Watt Power Supply | Power Supplies Sun Ultra 30 Sun Ultra 60 |
| 330-2141 | Front Bezel Assembly Front Bezel, Light Grey Dress Panel, Purple Power Switch Cover Peripheral Bezel with Cutouts | Sun Ultra 30 |
| 330-2142 | Front Bezel Assembly Front Bezel, Light Grey Dress Panel, Purple Power Switch Cover Peripheral Bezel with Cutouts | Sun Ultra 30 |
| 330-2143 | Front Bezel Assembly Front Bezel, Light Grey Dress Panel, Purple Power Switch Cover Peripheral Bezel with Cutouts | Sun Ultra 30 Sun Ultra 60 |
| 330-2145 | Foot Foot (cost reduced) | Sun Ultra 30 Sun Ultra 60 |
| 330-2148 | Disk Drive Bay Assembly/FRU Cable and Backplane Assembly Disk Drive Bay | Sun Ultra 30 Sun Ultra 60 |
| 330-2164 | Lower Right Side Cover | Sun Ultra 30 Sun Ultra 60 |
| 330-2165 | Upper Right Side and Top Cover | Sun Ultra 30 Sun Ultra 60 |
| 330-2166 | Front Bezel Assembly Front Bezel, Light Grey Dress Panel, Purple Power Switch Cover Peripheral Bezel with Cutouts | Sun Ultra 30 Sun Ultra 60 |
| 330-2186 | Peripheral Bezel Assembly 5 1/4" Filler Panel 3 1/2" Filler Panel Lightpipe (not replaceable) 5 1/4" Filler Panel with 3 1/2" Cutout Bezel (not replaceable) Power Button (not replaceable) | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 330-2187 | Peripheral Bezel Assembly 5 1/4" Filler Panel 3 1/2" Filler Panel Lightpipe (not replaceable) 5 1/4" Filler Panel with 3 1/2" Cutout Bezel (not replaceable) Power Button (not replaceable) | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 330-2731 | Foot Foot (cost reduced) | Sun Ultra 30 Sun Ultra 60 |
| 340-3534 | Chassis | Sun Ultra 30 Sun Ultra 60 |
| 340-3557 | Floppy and CD-ROM Bracket | Sun Ultra 30 Sun Ultra 60 |
| 340-3559 | Audio Module Filler Panel for Ultra 30 and 60 | Sun Blade 1000 Sun Blade 2000 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 340-4067 | Peripheral Assembly 3 1/2" Filler Panel 5 1/4" Filler Panel 5 1/4" Filler Panel with 3 1/2" Cutout Peripheral Bracket with Faceplate Bracket Faceplate | Sun Blade 1000 Sun Blade 2000 Sun Enterprise 250 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 340-4068 | Peripheral Assembly 3 1/2" Filler Panel 5 1/4" Filler Panel 5 1/4" Filler Panel with 3 1/2" Cutout Peripheral Bracket with Faceplate Bracket Faceplate | Sun Blade 1000 Sun Blade 2000 Sun Enterprise 250 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 340-5849 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 |
| 340-5850 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 |
| 340-5851 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 |
| 340-5852 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 |
| 340-5853 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 |
| 340-5854 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 |
| 340-5855 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 |
| 340-5856 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 |
| 340-6000 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 |
| 370-1414 | Microphone Microphone without Sun Logo Pocket Clip Adhesive Clip Panasonic CR2032 Battery | Input Device Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 30 |
| 370-1579 | Base Assembly (phased in July 1996) M3 × 6 mm Screw, Speaker Assembly Chassis Right Side Vent Panel Foot Right Front Corner Purple Chassis Label Left Front Corner Speaker SCSI I/O Board M2 × 5 mm Screw Bracket Internal SCSI Cable, 485 mm DC Wire Harness Speaker and LED Wire Harness (obsolete) Speaker and LED Wire Harness | SPARCstation 20 SPARCstation 4 SPARCstation 5 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 450 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 45 Sun Ultra 60 Sun Ultra 80 Sun-4m Architecture |
| 370-1678 | Microphone II Microphone II without Sun Logo Microphone II adapter for SS10, SS10SX, SPARCstation LX, SPARCclassic, and Speakerbox | Input Device Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 370-1922 | 14GB 8 mm Tape Drive 4X CD-ROM 4-8GB 4 mm DDS-2 Tape Drive 12-24GB 4 mm DDS-3 Tape Drive 7-14GB 8 mm Tape Drive 12X CD-ROM | Removable Media Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2102 | SunCD 4 CD-ROM Assembly/FRU M3 Shoulder Screw Mounting Grommet SunCD 4 CD-ROM Drive SunCD 12x CD-ROM Assembly M3 Shoulder Screw Mounting Grommet 12X CD-ROM Drive CD-ROM to CPU Audio Cable, 435 mm CD-ROM Filler Panel, Light Grey | Removable Media SPARCstation 20 SPARCstation 4 SPARCstation 5 Sun Netra 150 / E150 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2176 | 14GB 8 mm Tape Drive 4X CD-ROM 4-8GB 4 mm DDS-2 Tape Drive 12-24GB 4 mm DDS-3 Tape Drive 7-14GB 8 mm Tape Drive 12X CD-ROM | Removable Media Sun Netra 150 / E150 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 370-2256 | PGX 8-Bit Color Frame Buffer | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 370-2256-02 | Systems with a PGX PCI-based 8-bit Frame Buffer may display a vertical black stripe when running the OpenWindows environment. This occurs only with frame buffers with an Fcode version 1.09 (determined by reading the label on the EPROM located at U4 on the frame buffer: 113-377-1-109). | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 370-2365 | 1.05GB 5400 RPM Disk Drive Assembly 2.1GB 7200 RPM Disk Drive Assembly Mounting Bracket 1.05GB 5400 RPM Disk Drive, Conner 1 2.1GB 7200 RPM Disk Drive, IBM (disqualified) 2.1GB 7200 RPM Disk Drive, Seagate ST32550WC 2.1GB 7200 RPM Disk Drive, Seagate ST32171WC 2.1GB 7200 RPM Disk Drive, Fujitsu M2952 2.1GB 7200 RPM Disk Drive, Quantum VK22J05 | Disk (external) Disks by Part Number SCSI Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun SPARCstorage Array Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2366 | 1.05GB 5400 RPM Disk Drive Assembly 2.1GB 7200 RPM Disk Drive Assembly Mounting Bracket 1.05GB 5400 RPM Disk Drive, Conner 1 2.1GB 7200 RPM Disk Drive, IBM (disqualified) 2.1GB 7200 RPM Disk Drive, Seagate ST32550WC 2.1GB 7200 RPM Disk Drive, Seagate ST32171WC 2.1GB 7200 RPM Disk Drive, Fujitsu M2952 2.1GB 7200 RPM Disk Drive, Quantum VK22J05 | Disk (external) Disks by Part Number Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2367 | 4.2GB 5400 RPM Disk Drive Assembly 4.2GB 7200 RPM Disk Drive Assembly 9.1GB 7200 RPM Disk Drive Assembly Mounting Bracket 4.2GB 5400 RPM Disk, Seagate ST15230WC (obs) 4.2GB 5400 RPM Disk, Seagate ST15230WC 4.2GB 7200 RPM Disk, Seagate ST34371WC 4.2GB 7200 RPM Disk, Fujitsu M2954 4.2GB 7200 RPM Disk, Quantum VK45J05 9.1GB 7200 RPM Disk, Seagate ST19171WC 9.1GB 7200 RPM Disk, Fujitsu M2949 | Disk (external) Disks by Part Number SCSI Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun SPARCstorage Array Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2368 | 4.2GB 5400 RPM Disk Drive Assembly 4.2GB 7200 RPM Disk Drive Assembly 9.1GB 7200 RPM Disk Drive Assembly Mounting Bracket 4.2GB 5400 RPM Disk, Seagate ST15230WC (obs) 4.2GB 5400 RPM Disk, Seagate ST15230WC 4.2GB 7200 RPM Disk, Seagate ST34371WC 4.2GB 7200 RPM Disk, Fujitsu M2954 4.2GB 7200 RPM Disk, Quantum VK45J05 9.1GB 7200 RPM Disk, Seagate ST19171WC 9.1GB 7200 RPM Disk, Fujitsu M2949 | Disk (external) Disk (internal) Disks by Part Number Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2369 | 4.2GB 5400 RPM Disk Drive Assembly 4.2GB 7200 RPM Disk Drive Assembly 9.1GB 7200 RPM Disk Drive Assembly Mounting Bracket 4.2GB 5400 RPM Disk, Seagate ST15230WC (obs) 4.2GB 5400 RPM Disk, Seagate ST15230WC 4.2GB 7200 RPM Disk, Seagate ST34371WC 4.2GB 7200 RPM Disk, Fujitsu M2954 4.2GB 7200 RPM Disk, Quantum VK45J05 9.1GB 7200 RPM Disk, Seagate ST19171WC 9.1GB 7200 RPM Disk, Fujitsu M2949 | Disk (external) Disk (internal) Disks by Part Number Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Netra t1 Sun SPARCstorage Array Sun StorEdge A1000 Sun StorEdge Array Controller D1000 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2370 | 4.2GB 5400 RPM Disk Drive Assembly 4.2GB 7200 RPM Disk Drive Assembly 9.1GB 7200 RPM Disk Drive Assembly Mounting Bracket 4.2GB 5400 RPM Disk, Seagate ST15230WC (obs) 4.2GB 5400 RPM Disk, Seagate ST15230WC 4.2GB 7200 RPM Disk, Seagate ST34371WC 4.2GB 7200 RPM Disk, Fujitsu M2954 4.2GB 7200 RPM Disk, Quantum VK45J05 9.1GB 7200 RPM Disk, Seagate ST19171WC 9.1GB 7200 RPM Disk, Fujitsu M2949 | Disk (external) Disk (internal) Disks by Part Number Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Netra t1 Sun SPARCstorage Array Sun StorEdge A1000 Sun StorEdge Array Controller D1000 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2375 | 4-8GB 4 mm DDS-2 Tape Drive Assembly M3 × 6 mm Screw (obsolete) M3 × 6 mm Screw Mounting Bracket 4-8GB 4 mm DDS-2 Tape Drive, Light Grey | Removable Media Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 370-2377 | 12-24GB 4 mm DDS-3 Tape Drive Assembly M3 × 6 mm Screw (obsolete) M3 × 6 mm Screw Mounting Bracket 12-24GB 4 mm DDS-3 Tape Drive, Light Grey | Removable Media Sun Blade 1000 Sun Blade 2000 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 370-2728 | High Speed Serial Interface (HSI/P) 2M 80-Pin 4-Port DB37 RS449 Breakout Cable (obsolete) 2M 80-Pin 4-Port DB37 RS449 Breakout Cable 2M 80-Pin 4-Port DB37 RS449 Breakout Cable 2M 80-Pin 4-Port DB37 RS449 Breakout Cable Data Cable (not included and not sold) NEBS Level-3 80-Pin 4-Port DB37 RS449 Breakout Cable | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 370-2729 | Triple Density Floppy | Removable Media Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 370-2808 | 1.05GB 5400 RPM Disk Drive Assembly 2.1GB 7200 RPM Disk Drive Assembly Mounting Bracket 1.05GB 5400 RPM Disk Drive, Conner 1 2.1GB 7200 RPM Disk Drive, IBM (disqualified) 2.1GB 7200 RPM Disk Drive, Seagate ST32550WC 2.1GB 7200 RPM Disk Drive, Seagate ST32171WC 2.1GB 7200 RPM Disk Drive, Fujitsu M2952 2.1GB 7200 RPM Disk Drive, Quantum VK22J05 | Disk (external) Disk (internal) Disks by Part Number Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun SPARCstorage Array Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2809 | After extended run time in heavy disk access applications AND extended power down times Quantum (model# VK4550J or VK45J05) 4.2GB, 3 1/2-inch, 7200 RPM Single-Ended, Ultra/Wide SCSI disk drives may fail to spin up. These drives are at risk of premature failure due to oil contamination which causes a stiction failure in the HDA. Only disk drives in the following FRU serial number range are affected: 0005181-97041Dxxxx to 0005181-97440Dxxxx | Disk (external) Disk (internal) Disks by Part Number SCSI Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun SPARCstorage Array Sun StorEdge A3500 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-2810 | Serial Asychronous Interface (SAI/P) 8-Port I/O Panel and 78-Pin Cable Data Cable (not included and not sold) NEBS Level-3 8-Port I/O Panel and 78-Pin Cable, Option X1001A | Communication Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 370-2811 | FDDI/P SAS 1.0/2.0 Fiber FDDI/P DAS 1.0/2.0 Fiber FDDI Cable Assembly MIC to MIC Coupler 3 Meter FDDI Cable, SC Duplex to MIC | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 370-2812 | FDDI/P SAS 1.0/2.0 Fiber FDDI/P DAS 1.0/2.0 Fiber FDDI Cable Assembly MIC to MIC Coupler 3 Meter FDDI Cable, SC Duplex to MIC | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 370-2816 | SunCD 4 CD-ROM Assembly/FRU M3 Shoulder Screw Mounting Grommet SunCD 4 CD-ROM Drive SunCD 12x CD-ROM Assembly M3 Shoulder Screw Mounting Grommet 12X CD-ROM Drive CD-ROM to CPU Audio Cable, 435 mm CD-ROM Filler Panel, Light Grey | Removable Media SPARCstation 5 Sun Netra 150 / E150 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Systems Telco Netra t 1100 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 370-2881 | 7-14GB 8 mm Tape Drive Assembly M3 × 6 mm Screw (obsolete) M3 × 6 mm Screw Mounting Bracket 7-14GB 8 mm Tape Drive, Light Grey | Removable Media Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 370-2882 | 7-14GB 8 mm Tape Drive (Medium Grey Bezel) | Removable Media Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Fire 280R Sun Ultra 30 Sun Ultra 80 |
| 370-3278 | SunVideo Plus | Graphics Sun Ultra 30 |
| 370-3279 | 4-8GB 1/4" SLR Tape Drive Assembly Mounting Bracket 4-8GB 1/4" SLR Tape Drive, Light Grey | Removable Media Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 370-3403 | 8.4 GB Wide SCSI Disk Card with 2x 4.2GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 4.2GB 7200 RPM Disk Drive FRU 4.2GB Disk Drive, Seagate ST34371WC 4.2GB Disk Drive, Quantum VK45J05 4.2GB Disk Drive, IBM DDRS-34560 4.2GB Disk Drive, Fujitsu MAB3045SC | Disk (external) Disk (internal) Disks by Part Number SCSI Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun SPARCstorage Array Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-3404 | 18.2 GB Wide SCSI Disk Card with 2x 9.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 9.1GB 7200 RPM Disk Drive FRU 9.1GB Disk Drive, IBM DDRS-39130 9.1GB Disk Drive, Fujitsu MAB3091SC 9.1GB Disk Drive, Seagate ST39173WC 9.1GB Disk Drive, Fujitsu MAE3091LC 9.1GB Disk Drive, IBM DNES-309170 | Disk (external) Disk (internal) Disks by Part Number SCSI Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-3412 | 8.4 GB Wide SCSI Disk Card with 2x 4.2GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 4.2GB 7200 RPM Disk Drive FRU 4.2GB Disk Drive, Seagate ST34371WC 4.2GB Disk Drive, Quantum VK45J05 4.2GB Disk Drive, IBM DDRS-34560 4.2GB Disk Drive, Fujitsu MAB3045SC | Disk (external) Disk (internal) Disks by Part Number SCSI Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-3413 | 18.2 GB Wide SCSI Disk Card with 2x 9.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 9.1GB 7200 RPM Disk Drive FRU 9.1GB Disk Drive, IBM DDRS-39130 9.1GB Disk Drive, Fujitsu MAB3091SC 9.1GB Disk Drive, Seagate ST39173WC 9.1GB Disk Drive, Fujitsu MAE3091LC 9.1GB Disk Drive, IBM DNES-309170 | Disk (external) Disks by Part Number SCSI Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 370-3415 | 12x CD-ROM, 1.6" Height 32x CD-ROM, 1.6" Height 4.2GB 7200 RPM 1.6" Height Disk Drive Assembly 9.1GB 7200 RPM 1.6" Height Disk Drive Assembly | Removable Media Sun Enterprise 250 Sun Fire 280R Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 Systems Telco Netra t 1100 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 370-3595 | 18.2 GB Wide SCSI Disk Card with 2x 9.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 9.1GB 7200 RPM Disk Drive FRU 9.1GB Disk Drive, IBM DDRS-39130 9.1GB Disk Drive, Fujitsu MAB3091SC 9.1GB Disk Drive, Seagate ST39173WC 9.1GB Disk Drive, Fujitsu MAE3091LC 9.1GB Disk Drive, IBM DNES-309170 | Disk (external) Disks by Part Number SCSI Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 T3 |
| 370-3649 | 9.1GB 10000 RPM Disk Drive Assembly/FRU 9.1GB Disk Drive, Seagate ST39102LC 9.1GB Disk Drive, Fujitsu MAG3091LC | Disk (external) Disks by Part Number Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun Ultra 30 Sun Ultra 60 T3 |
| 370-3753 | PGX32 8/24-Bit Color Frame Buffer | Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire V480 Sun Fire V880 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0001 | Token Ring Interface (TRI/P) Token Ring Interface (TRI/P) 9-Pin Data Cable (not included and not sold) | Communication Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 375-0002 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Enterprise 10000 Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 |
| 375-0005 | Dual Single-Ended Ultra SCSI without FCode Dual Single-Ended Ultra SCSI with FCode ( not released ) E450 Internal A-Port and B-Port Cable External HD68 to VHDCI68 Cable, 80 cm External HD68 to VHDCI68 Cable, 2M | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge L9 Sun StorEdge S1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0006 | SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected. | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0073 | Token Ring Interface (TRI/P) Token Ring Interface (TRI/P) 9-Pin Data Cable (not included and not sold) | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 375-0100 | Serial Asychronous Interface (SAI/P) 3.0 NEBS Level-3 8-Port I/O Panel and 78-Pin Cable Data Cable (not included and not sold) | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 390-0004 | 18.2 GB Wide SCSI Disk Card with 2x 9.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 9.1GB 7200 RPM Disk Drive FRU 9.1GB Disk Drive, IBM DDRS-39130 9.1GB Disk Drive, Fujitsu MAB3091SC 9.1GB Disk Drive, Seagate ST39173WC 9.1GB Disk Drive, Fujitsu MAE3091LC 9.1GB Disk Drive, IBM DNES-309170 | Disk (external) Disk (internal) Disks by Part Number SCSI Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 390-0005 | 9.1GB 7200 RPM Disk Drive Assembly Mounting Bracket 9.1GB Disk, IBM DDRS-39130 (removed by WO_12576) 9.1GB Disk Drive, Fujitsu MAB3091SC 9.1GB Disk Drive, Seagate ST39173WC 9.1GB Disk Drive, Fujitsu MAE3091LC 9.1GB Disk Drive, Fujitsu MAG3091LC 9.1GB Disk Drive, IBM DNES-309170 | Disk (external) Disk (internal) Disks by Part Number Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun Ultra 30 Sun Ultra 60 |
| 390-0007 | 18.2 GB Wide SCSI Disk Card with 2x 9.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 9.1GB 7200 RPM Disk Drive FRU 9.1GB Disk Drive, IBM DDRS-39130 9.1GB Disk Drive, Fujitsu MAB3091SC 9.1GB Disk Drive, Seagate ST39173WC 9.1GB Disk Drive, Fujitsu MAE3091LC 9.1GB Disk Drive, IBM DNES-309170 | Disk (external) Disk (internal) Disks by Part Number SCSI Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra t1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 390-0009 | 9.1GB 10000 RPM Disk Drive Assembly Mounting Bracket 9.1GB Disk Drive, Seagate ST39103LC 9.1GB Disk Drive, Seagate ST39204LC | Disk (external) Disks by Part Number Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun Ultra 30 Sun Ultra 60 T3 |
| 390-0028 | Removable Media Module EMI Cover 32x CD-ROM Assembly 10x DVD-ROM Assembly/FRU 12-24GB 4 mm DDS-3 Tape Drive Assembly/FRU 12-24GB 4 mm DDS-3 Tape Drive 20-40GB 4 mm DDS-4 Tape Drive Assembly/FRU 20-40GB 4 mm DDS-4 Tape Drive 20-40GB 4 mm DDS-4 Tape Drive Assembly/FRU 20-40GB 4 mm DDS-4 Tape Drive | Removable Media Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 Systems Telco Netra ct 800 |
| 390-0037 | 9.1GB 10000 RPM Disk Drive Assembly Mounting Bracket 9.1GB Disk Drive, Seagate ST39103LC 9.1GB Disk Drive, Seagate ST39204LC | Disk (external) Disks by Part Number Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun Ultra 30 Sun Ultra 60 T3 |
| 501-2479 | 32 MB (2 × 16MB DIMMS) | Memory SPARCstation 20 Sun Enterprise 250 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun-4 Architecture (Generic) |
| 501-2480 | CPUSET-2P-512MB 512MB Memory 2× 300MHz Modules 64MB 501-2480 64MB 370-4389 300MHz 501-4849 | Memory SPARCstation 20 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun-4 Architecture (Generic) Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-2622 | 64MB SIMM 32MB SIMM 128MB SIMM 64MB SIMM | Memory SPARCstation 20 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun-4 Architecture (Generic) Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-2741 | SunSwift SCSI/Ethernet SunSwift SCSI/Ethernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge S1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3027 | SunATM-155/UTP 3.0/4.0 SunATM-155/MFiber 3.0/4.0 SunATM-622/MFiber 3.0/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3028 | SunATM-155/UTP 3.0/4.0 SunATM-155/MFiber 3.0/4.0 SunATM-622/MFiber 3.0/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3029 | SunATM-155/UTP 3.0/4.0 SunATM-155/MFiber 3.0/4.0 SunATM-622/MFiber 3.0/4.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Communication Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V1280 Sun Fire V440 Sun Fire V480 Sun Fire V880 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-3136 | 64MB SIMM 32MB SIMM 128MB SIMM 64MB SIMM | Memory Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun StorEdge N8200 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-4172 | Creator3D Series 2 (FFB2) | Sun Ultra 30 Sun Ultra 60 |
| 501-4174 | Creator Series 2 (FFB2) | Sun Ultra 30 Sun Ultra 60 |
| 501-4196 | Ultra 2 Model 1300 UPA Bus Terminator Module recommended on uni-processor models. An unterminated UPA bus may exhibit noise problems in very high intensity UPA bus activity applications. Symptoms may include CPU ECache data parity errors, ECC errors, asynch data errors or hangs. | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-4278 | 250MHz UltraSPARC II Module | Sun Enterprise 450 Sun Ultra 30 |
| 501-4359 | SunFastEthernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-4366 | Sun Quad FastEthernet Sun Quad FastEthernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-4366-04 | When one or more PCI QFE cards are plugged into 33MHz slot(s), the Ultra 30 does not come out of reset when powered up. | Sun Ultra 30 |
| 501-4373 | GigabitEthernet 1.0 GigabitEthernet 2.0 SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 501-4788 | Creator3D Series 3 (FFB2+) | Graphics Sun Blade 1000 Sun Blade 2000 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 501-4788-05 | Systems with FFB2+ installed may experience right shift of horizontal lines that contain the cursor and/or border line curves toward the mouse pointer when the mouse pointer is placed close to the left border of a cmdtool window. This can be easily seen when you set the FFB resolution to 960x680x112s with cmdtool's foreground color set to black and background to white. | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 501-4789 | Creator Series 3 (FFB2+) | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 501-4789-05 | Systems with FFB2+ installed may experience right shift of horizontal lines that contain the cursor and/or border line curves toward the mouse pointer when the mouse pointer is placed close to the left border of a cmdtool window. This can be easily seen when you set the FFB resolution to 960x680x112s with cmdtool's foreground color set to black and background to white. | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 501-4849 | CPUSET-2P-512MB 512MB Memory 2× 300MHz Modules 64MB 501-2480 64MB 370-4389 300MHz 501-4849 | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 45 Sun Ultra 60 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-4857 | 250MHz UltraSPARC II Module | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 30 |
| 501-4860 | Elite3D-m6/FRU 501-5201 + 501-5058 | Graphics Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 501-5019 | Sun FastEthernet PCI Adapter (FE/P) 2.0 | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-5406 | Sun Quad FastEthernet Sun Quad FastEthernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-5426 | GigabitEthernet FC-AL/P SC Duplex 50/125 Multimode Fibre Optical Cable, 2M SC Duplex 50/125 Multimode Fibre Optical Cable, 5M SC Duplex 50/125 Multimode Fibre Optical Cable, 15M | Ethernet Sun Blade 100 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 501-5484 | Elite3D-m3 | Graphics Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 501-5656 | SunSwift SCSI/Ethernet SunSwift SCSI/Ethernet RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M | Ethernet SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge S1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 501-5690 | Creator3D Series 3 (FFB2+) | Graphics Sun Blade 1000 Sun Blade 2000 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 501-5691 | 64MB SIMM 32MB SIMM 128MB SIMM 64MB SIMM | Memory Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 501-5727 | PCI adapters in F12K/15K domains may intermittently fail following a reset, reboot or "setkeyswitch on" operation. The failure may prevent the domain from booting or cause a loss of access to devices such as disks or networks. It is also possible for the failure to cause an OS panic. Any panic may potentially cause disk file system corruption. | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3120 Sun StorEdge 3310 Sun StorEdge S1 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 501-6635 | Dual GigabitEthernet / Dual SCSI PCI Adapter | Ethernet SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V20z Sun Fire V210 Sun Fire V240 Sun Fire V40z Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3120 Sun StorEdge 3310 Sun StorEdge S1 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 525-1430 | U2006 U2006 U13 U13 U13 U13 U2706 U2706 U2706 U3104 U3008 U48 U48 U2101 J3601 SCCR SCCR SCCR U25 SCCR U25 SCCR U25 SCCR U2101 U2101 U1804 U4618 U0205 U2501 U2106 ID Board | IDPROM Sun Enterprise 220R Sun Enterprise 420R Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| 525-1669 | 105930 | Sun Ultra 30 |
| 530-1871 | StorEdge Remote Response (595-6264 and 595-6279) RJ45 to RJ45 Cable, .38M Terminal Concentrator Modem (not included with 595-6279) International AC Power Adapter Kit RJ45 to DB25 Modem Adapter RJ45 to RJ45 Cable, 4M Category 5, Back-to-Back, RJ45 to RJ45, 1.0M RJ45 to RJ45 Rollover Cable Terminal Concentrator Rack Mount Kit | Cables Data Cables by Type Cables External Data Cables by Type Communication Ethernet SCSI Sun Enterprise 250 Sun Enterprise 3000 Sun Enterprise 3500 Sun Enterprise 4000 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5000 Sun Enterprise 5500 Sun Enterprise 6000 Sun Enterprise 6500 Sun StorEdge 3900/6900 Sun StorEdge 6320 System Sun StorEdge 6900 series Sun Ultra 1 Sun Ultra 10 Sun Ultra 2 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun-4 Architecture (Generic) Sun-4m Architecture Sun4d System SPARCserver 1000 and 1000E |
| 530-2068 | HD26 to 36-Pin Centronics Parallel Port Cable, 5M HD26 to DB25 IBM Parallel Port Cable, 5M DB25 to 36-Pin Centronics Parallel Cable, 5M | Printers Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 1 Sun Ultra 10 Sun Ultra 2 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun-4m Architecture |
| 530-2093 | Twisted Pair Ethernet Cables 530-1871-xx, Category 3, RJ45 to RJ45, 4M 530-1871-04, Category 5, RJ45 to RJ45, 4M Shielded RJ45 to RJ45, 4M Shielded RJ45 to RJ45, 2M Shielded RJ45 to RJ45, 6M Category 5, Back-to-Back, RJ45 to RJ45, 1.0M Category 5, Back-to-Back, RJ45 to RJ45, 5.0M | Cables Data Cables by Type Cables External Data Cables by Type Communication Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 250 Sun Enterprise 3000 Sun Enterprise 3500 Sun Enterprise 4000 Sun Enterprise 4500 Sun Enterprise 5000 Sun Enterprise 5500 Sun Enterprise 6000 Sun Enterprise 6500 Sun Fire B1600 Blade System Chassis Sun Fire V100 Sun Fire V490 Sun Netra 240 Server Sun Netra 440 Server Sun Netra t1 Sun StorEdge 6320 System Sun StorEdge 6920 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun-4 Architecture (Generic) Sun-4m Architecture |
| 530-2322 | Disk Drive Bay Assembly/FRU Cable and Backplane Assembly Disk Drive Bay | Sun Ultra 30 Sun Ultra 60 |
| 530-2345 | Peripheral DC Wire Harness DC Extension Cable for SLR Tape Drive | Sun Ultra 30 Sun Ultra 60 |
| 530-2346 | Floppy Data Cable | Sun Blade 1000 Sun Blade 2000 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 530-2502 | Peripheral DC Wire Harness DC Extension Cable for SLR Tape Drive | Removable Media Sun Enterprise 250 Sun Ultra 30 Sun Ultra 60 |
| 530-2867 | Noise Reduction Kit, Option 2087 Voltage Regulated Fan Power Cable | Sun Ultra 30 Sun Ultra 60 |
| 540-2540 | M3 Machine Screw, CPU, P/S, and Top Cover Spring for M3 Screw, CPU, P/S, and Top Cover Sun Logo SPARCstation 5 Nameplate SPARCserver 5 Nameplate Netra i Nameplate Floppy Interface Board Netra s Nameplate Top Cover Assembly Tinnerman Clip (added to 540-2434-03) Lockbox Assembly | SPARCstation 20 SPARCstation 4 SPARCstation 5 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 250 Sun Ultra 1 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 Sun-4m Architecture |
| 540-2923 | Front Bezel Assembly Front Bezel, Light Grey Dress Panel, Purple Power Switch Cover Peripheral Bezel with Cutouts | Sun Ultra 30 |
| 540-2936 | 4.2 GB Wide SCSI Disk Card with 4x 2.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 2.1GB 7200 RPM Disk Drive FRU 2.1GB Disk Drive, Seagate ST32550WC 2.1GB Disk Drive, IBM DFHS-32160 2.1GB 7200 RPM Disk Drive FRU 2.1GB Disk Drive, Seagate ST32171WC 2.1GB Disk Drive, Quantum VK22J05 | Disk (external) Disk (internal) Disks by Part Number SCSI Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra 150 / E150 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 T3 |
| 540-2938 | 8.4 GB Wide SCSI Disk Card with 2x 4.2GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 4.2GB 7200 RPM Disk Drive FRU 4.2GB Disk Drive, Seagate ST34371WC 4.2GB Disk Drive, Quantum VK45J05 4.2GB Disk Drive, IBM DDRS-34560 4.2GB Disk Drive, Fujitsu MAB3045SC | Disk (external) Disk (internal) Disks by Part Number SCSI Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra 150 / E150 Sun Ultra 1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Systems Telco Netra t 1100 Systems Telco Netra t 1120 T3 |
| 540-2951 | 4.2GB 7200 RPM Disk Drive Assembly/FRU 9.1GB 7200 RPM Disk Drive Assembly/FRU 18.2GB 7200 RPM Disk Drive Assembly/FRU 36.4GB 10000 RPM Disk Drive Assembly/FRU | Disk (external) Disk (internal) Disks by Part Number Sun Ultra 30 Sun Ultra 60 Systems Telco Netra t 1100 Systems Telco Netra t 1120 |
| 540-2975 | Speaker FRU Assembly Speaker | Sun Ultra 30 Sun Ultra 60 |
| 540-2986 | System Board Fan and Shroud Assembly | Sun Ultra 30 |
| 540-2991 | On/Off Switch and Cable Assembly | Sun Ultra 30 Sun Ultra 60 |
| 540-3015 | Left Side Cover, Purple | Sun Ultra 30 |
| 540-3016 | Disk Drive Bay Assembly/FRU Cable and Backplane Assembly Disk Drive Bay | Sun Ultra 30 Sun Ultra 60 |
| 540-3017 | PCI Fan Assembly/FRU | Sun Ultra 30 Sun Ultra 60 |
| 540-3024 | Ultra 1, Ultra 2 Ultra 30, Ultra 60, Ultra 80 E250, E450, E220R, E420R Sun Blade 1000 E150, nfs 150, i 150 MultiPack, E3000, E3500 A1000, D1000, A3500 A5000, A5100, A5200, A7000 Netra ct 400, Netra ct 800 st D130, st A1000, st D1000 | Disk (external) Disk (internal) Disk Spud Bracket Disks by Part Number Sun Blade 1000 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire E2900 Sun Fire E2900, RoHS:YL Sun Fire V120 Sun Fire V125 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V250 Server Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 120 Sun Netra 1280 Server Sun Netra 1280 Server, RoHS:YL Sun Netra 1290, RoHS:YL Sun Netra 20 Sun Netra 240 Server Sun Netra 240 Server, RoHS:YL Sun Netra 440 Server Sun Netra 440 Server, RoHS:YL Sun Netra st D130 Sun Netra st D130 Disk Sun Netra t 1400 Sun Netra t 1400/1405 Disks Sun Netra t 1405 Server Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5200 Sun StorEdge Array Controller D1000 Sun StorEdge D2 Sun StorEdge N8200 Sun StorEdge S1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 T3 |
| 540-3025 | Ultra 1, Ultra 2 Ultra 30, Ultra 60, Ultra 80 E250, E450, E220R, E420R Sun Blade 1000 E150, nfs 150, i 150 MultiPack, E3000, E3500 A1000, D1000, A3500 A5000, A5100, A5200, A7000 Netra ct 400, Netra ct 800 st D130, st A1000, st D1000 | Disk (external) Disk (internal) Disk Spud Bracket Disks by Part Number Sun Enterprise 3500 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge A5000 Sun StorEdge A5100 Sun StorEdge Array Controller D1000 Sun Ultra 30 Sun Ultra 60 |
| 540-3623 | Elite3D-m6 | Graphics Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 540-3704 | 18.2 GB Wide SCSI Disk Card with 2x 9.1GB Disk Drives Wide SCSI Disk Card FRU without Disk Drives 9.1GB 7200 RPM Disk Drive FRU 9.1GB Disk Drive, IBM DDRS-39130 9.1GB Disk Drive, Fujitsu MAB3091SC 9.1GB Disk Drive, Seagate ST39173WC 9.1GB Disk Drive, Fujitsu MAE3091LC 9.1GB Disk Drive, IBM DNES-309170 | Disk (external) Disk (internal) Disks by Part Number SCSI Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Netra t1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Systems Telco Netra t 1120 Systems Telco Netra t 1125 T3 |
| 540-3881 | Empty 1.0" Disk Drive Slot Filler 9.1GB 10000 RPM Disk Drive FRU, NEBS Level 3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2/3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 | Disk (external) Disk (internal) Disks by Part Number Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge Array Controller D1000 Sun Ultra 30 Sun Ultra 60 T3 |
| 540-3902 | Elite3D-m6 | Graphics Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 560-2548 | Option X9627A Left Rear Rail Right Rear Rail Left Front Rail Right Front Rail Tray Mounting Bar, Ultra 80 Left Top Bracket, Ultra 80 Right Top Bracket, Ultra 80 Mounting Bar, Ultra 30/60 | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-1737 | SunDials 8-dial interactive graphics I/O for 3-D | Input Device Sun Ultra 10 Sun Ultra 2 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 Sun-4 Architecture (Generic) |
| 595-1865 | SunButtons 32-key function I/O device | Input Device Sun Enterprise 450 Sun Ultra 10 Sun Ultra 2 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 Sun-4 Architecture (Generic) |
| 595-3780 | SunFastEthernet 1.0/1.1 Assembly/FRU SunFastEthernet 1.0/1.1 SBus Card SunFastEthernet Transceiver Card RJ45 to RJ45 Cable, 4M Shielded RJ45 to RJ45 Cable, 4M MII to AUI Converter (requires AC power) | Cables Data Cables by Type Cables External Data Cables by Type Ethernet Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3000 Sun Enterprise 3500 Sun Enterprise 4000 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5000 Sun Enterprise 5500 Sun Enterprise 6000 Sun Enterprise 6500 Sun Ultra 1 Sun Ultra 10 Sun Ultra 2 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 595-3803 | 370-2102 [F] | Sun Ultra 30 Sun Ultra 60 |
| 595-3810 | 501-2479 [F] (16MB) | Sun Enterprise 250 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 595-3811 | 501-2622 [F] (32MB) | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 595-3812 | 501-2480 [F] (64MB) | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 595-3813 | 501-3136 [F] (128MB) | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun StorEdge N8200 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 595-3877 | 370-2176 [F] | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-3972 | 370-1922 [F] | Sun Ultra 30 Sun Ultra 60 |
| 595-4045 | 540-2936 [F] Spud Bracket FRU w/ 1" Bracket 540-3024 | Sun Ultra 30 Sun Ultra 60 |
| 595-4046 | 370-2816 [F] | Sun Ultra 30 Sun Ultra 60 |
| 595-4082 | 540-2938 [F] Spud Bracket FRU w/ 1" Bracket 540-3024 | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 595-4151 | 540-2951 [F] Spud Bracket FRU w/ 1.6" Bracket 540-3025 | Sun Ultra 30 Sun Ultra 60 |
| 595-4161 | 370-2377 [F] | Sun Ultra 30 |
| 595-4163 | 370-2377 [F] | Sun Blade 1000 Sun Blade 2000 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-4258 | 501-5656 [F] | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge S1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 595-4380 | 370-2256 [F] | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 595-4384 | 370-2881 [F] | Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-4394 | 501-4172 [F] | Sun Ultra 30 Sun Ultra 60 |
| 595-4395 | 501-4174 [F] | Sun Ultra 30 Sun Ultra 60 |
| 595-4399 | 375-0005 [F] | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun StorEdge L9 Sun StorEdge S1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 595-4400 | 370-2729 [F] | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-4414 | 375-0006 [F] | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L9 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 595-4498 | 501-5019 [F] | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 595-4566 | 370-3279 [F] | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-4603 | 370-3278 [F] | Sun Ultra 30 |
| 595-4605 | 501-5690 [F] | Sun Blade 1000 Sun Blade 2000 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 595-4607 | 501-4789 [F] | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| 595-4716 | 540-3704 [F] Spud Bracket FRU w/ 1" Bracket 540-3024 | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Netra t1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| 595-4749 | 370-3415 [F] | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-4870 | 540-3902 [F] | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-4871 | 501-5484 [F] | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-4893 | 501-4857 [F] | Sun Enterprise 250 Sun Ultra 30 |
| 595-4894 | 501-4849 [F] | Sun Enterprise 250 Sun Ultra 30 Sun Ultra 60 |
| 595-4939 | 540-3881 [F] Spud Bracket FRU w/ 1" Bracket 540-3024 | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Netra t1 Sun Ultra 30 Sun Ultra 60 |
| 595-5146 | 370-3753 [F] | Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire V480 Sun Fire V880 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 595-5364 | Noise Reduction Kit, Option 2087 Voltage Regulated Fan Power Cable | Sun Ultra 30 Sun Ultra 60 |
| 595-5414 | 501-5426 [F] | Ethernet Sun Blade 100 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-5431 | 390-0028 [F] | Removable Media Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R Sun Netra 20 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 595-5624 | 501-5727 [F] | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge S1 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 605-1581 | 370-2728 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 605-1582 | 370-2810 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 605-1583 | 370-2811 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 605-1584 | 370-2812 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 605-1590 | 375-0001 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| 605-1591 | 375-0002 [F] | Sun Enterprise 10000 Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 |
| 605-1594 | 501-5406 [F] | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 605-1598 | 501-3027 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire V120 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 605-1599 | 501-3028 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 605-1600 | 501-3029 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| 605-1601 | 501-4373 [F] | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 2000 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire V120 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| 806-1453 | Rack Mount Installation Guide | Sun Ultra 30 |
| X1032A | Sun Fire 15K system domains containing SunSwift PCI SCSI/ethernet combo adapters, may encounter SCSI errors. | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge S1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1033A | 501-5019 [F] | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1034A | 501-5406 [F] | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1035A | 370-2811 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1036A | 370-2812 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1039A | 375-0001 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| X1040A | 370-2728 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| X1041A | 370-2810 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| X1044A | 375-0002 [F] | Sun Enterprise 10000 Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 30 |
| X1066A | 501-3028 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1067A | 501-3027 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1068A | 501-3029 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X1086A | 370-3278 [F] | Sun Ultra 30 |
| X1141A | Adapter boards capable of 66MHz operation may only run at 33MHz when installed into 66MHz PCI I/O slots on Sun Fire 12K/15K platforms. | Ethernet Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X1190A | 501-4857 [F] | Sun Enterprise 250 Sun Ultra 30 |
| X1191A | 501-4196 [F] 501-4849 [F] | Sun Enterprise 250 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Systems Telco Netra t 1120 Systems Telco Netra t 1125 |
| X180A | 595-1865 | Sun Enterprise 450 Sun Ultra 10 Sun Ultra 2 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X190A | 595-1737 | Sun Ultra 10 Sun Ultra 2 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X2069A | 501-5426 [F] | Ethernet Sun Blade 100 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire V120 Sun Netra t1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X2087A | PCI Fan Assembly | Sun Ultra 30 Sun Ultra 60 |
| X2222A | PCI adapters in F12K/15K domains may intermittently fail following a reset, reboot or "setkeyswitch on" operation. The failure may prevent the domain from booting or cause a loss of access to devices such as disks or networks. It is also possible for the failure to cause an OS panic. Any panic may potentially cause disk file system corruption. | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 10000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3120 Sun StorEdge 3310 Sun StorEdge S1 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X3658A | 501-4174 [F] | Sun Ultra 30 Sun Ultra 60 |
| X3659A | 501-4172 [F] | Sun Ultra 30 Sun Ultra 60 |
| X3660A | 370-2256 [F] | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| X3662A | 501-4789 [F] | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| X3663A | 501-5690 [F] | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 |
| X3664A | 501-5484 [F] | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X3665A | 540-3902 [F] | Sun Ultra 10 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X3668A | If the Emulex FC HBA card is placed on the same PCI Bus with any other PCI card which causes the Schizo chip to attempt a 64-bit PIO, a system panic would most likely result. The problem will not occur if the Emulex HBA card is installed alone on a PCI Bus. UltraSparc-III platforms utilizing the Schizo 2.1 or 2.2 ASIC may experience panics due to address parity errors on the PCI Bus. The problem has been seen on the Sun Fire 280R with the Emulex FC HBA card in combination with a PGX32 card installed on the same PCI Bus. This condition occurs when a card on the PCI Bus detects a 64-bit parity address error on the PCI Bus while another card on the same PCI Bus is performing a 64-bit PIO. The following error messages are displayed prior to a system panic: WARNING: pcisch-0: PCI fault log start: PCI SERR PCI error occurred on device #6 dwordmask=0 bytemask=0 PCI primary error (0): pcisch-0: PCI secondary error (0): pcisch-0: PBM AFAR 0.00000000: pcisch-0: PCI config space error status (4280): signaled system error. pcisch-0: PCI fault log end. panic[cpu1]/thread=2a10000bd40: pcisch-0: PCI bus 2 error(s)! | Sun Blade 100 Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Fire 280R Sun Fire 3800 Sun Fire 4800 Sun Fire 6800 Sun Fire V480 Sun Fire V880 Sun Netra 20 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X4422A | 501-6635 [F] | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V20z Sun Fire V210 Sun Fire V240 Sun Fire V245 Sun Fire V40z Sun Fire V440 Sun Fire V445 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge 3120 Sun StorEdge 3310 Sun StorEdge S1 Sun Ultra 25 Sun Ultra 30 Sun Ultra 45 Sun Ultra 60 Sun Ultra 80 |
| X467A | 595-3780 [F] | Cables Data Cables by Type Cables External Data Cables by Type Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 450 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 10 Sun Ultra 2 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 |
| X495A | F370-1414 [F] | Sun Enterprise 3500 Sun Enterprise 4500 Sun Enterprise 5500 Sun Enterprise 6500 Sun Ultra 30 |
| X5214A | 540-2938 [F] | Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| X5229A | 540-3704 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Netra t1 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| X5234A | 540-3881 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Netra t1 Sun Ultra 30 Sun Ultra 60 |
| X5251A | 540-2951 [F] | Sun Ultra 30 Sun Ultra 60 |
| X6004A | 370-2729 [F] | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X6106A | 370-3279 [F] | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X6153A | 370-2102 [F] | Sun Ultra 30 Sun Ultra 60 |
| X6161A | 370-2816 [F] | Sun Ultra 30 Sun Ultra 60 |
| X6166A | 370-3415 [F] | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X6203A | 370-1922 [F] | Sun Ultra 30 Sun Ultra 60 |
| X6212A | 370-2881 [F] | Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X6213A | 370-2882 [F] | Sun Enterprise 250 Sun Enterprise 3500 Sun Enterprise 420R Sun Enterprise 450 Sun Enterprise 4500 Sun Fire 280R Sun Ultra 30 Sun Ultra 80 |
| X6256A | 370-2176 [F] | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X6280A | 370-2377 [F] | Sun Ultra 30 |
| X6282A | 370-2377 [F] | Sun Blade 1000 Sun Blade 2000 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X6295A | 390-0028 [F] | Removable Media Sun Blade 1000 Sun Blade 2000 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X6520A | 540-2936 [F] | Sun Ultra 30 Sun Ultra 60 |
| X6540A | 375-0005 [F] | SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire V120 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun StorEdge L9 Sun StorEdge S1 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X6541A | SCSI Bus error messages may appear at boot time when Sun StorEdge L7 Tape Autoloader units are attached to Dual Differential Ultra/Wide SCSI (PCI) Host Bus Adapters (Option X6541A). These messages can be ignored and the tape Unit will function normally once the host has booted up. This issue affects any Sun StorEdge L7 Tape Autoloader attached to an X6541A HBA on a platform running Solaris 8 or Solaris 9. Other versions of Solaris are not affected. | Allgemein / Unbekannt SCSI Sun Blade 100 Sun Blade 1000 Sun Blade 150 Sun Blade 1500 Sun Blade 2000 Sun Blade 2500 Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 420R Sun Enterprise 450 Sun Fire 12K / 15K Sun Fire 280R Sun Fire 4800 Sun Fire 6800 Sun Fire E25K Sun Fire V120 Sun Fire V1280 Sun Fire V210 Sun Fire V240 Sun Fire V440 Sun Fire V480 Sun Fire V490 Sun Fire V880 Sun Fire V890 Sun Netra 20 Sun Netra t1 Sun StorEdge A1000 Sun StorEdge A3500 Sun StorEdge Array Controller D1000 Sun StorEdge L1000 Sun StorEdge L180 Sun StorEdge L20 / L40 / L60 Sun StorEdge L25/L100 Sun StorEdge L3500 Sun StorEdge L5500 Sun StorEdge L7 Sun StorEdge L700 Sun StorEdge L9 Sun StorEdge N8200 Sun Ultra 10 Sun Ultra 30 Sun Ultra 5 Sun Ultra 60 Sun Ultra 80 |
| X7001A | 501-2479 [F] | Sun Enterprise 250 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| X7002A | 501-2622 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| X7003A | 501-2480 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| X7004A | 501-3136 [F] | Sun Enterprise 220R Sun Enterprise 250 Sun Enterprise 450 Sun StorEdge N8200 Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 |
| X7043A | 501-5691 [F] | Memory Sun Enterprise 250 Sun Enterprise 420R Sun Ultra 2 Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |
| X9627A | 560-2548 340-5849 340-5850 340-5851 340-5852 340-5853 340-5854 340-5855 340-5856 340-6000 | Sun Ultra 30 Sun Ultra 60 Sun Ultra 80 |